SW0801-LR110105MLLVIINCE GR UP GEOTECHNICRL Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 11/23/2010 Report Date: 01/05/2011 Previously Reported: 12/14/2010 Sampled By: Walker, III, John Project: Sidewalk Improvements By Order Of: Larry Davis Location: Northbound sidewalk exterior lane beginning at 150 S. Denton Order Number: 1770 Tap Rd. at intersection of Braewood Number of Client: The City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95196 Material: Concrete Test Method: See Below TEST RESULTS Report No: 95196 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (lbs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 39,410 Type 2 Lab 3,140 3,140 B 28 4.00 12.57 57,230 Type 3 Lab 4,550 C 28 4.00 12.57 57,705 Type 3 Lab 4,590 4,570 D HOLD (see remarks) - II 1 jj11ff Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Date Received: 11/24/2010 Slump: 4.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 5.1% Source /Sampled At: Truck / Center Time Sampled: 1:40 pm Plant: P136 Temp.: Ambient: 69 °F Mix: 79 °F Mix Code: 10J11504 Truck/Ticket No: 1185 / 25271874 Unit Weight: 148.1 # /cu ft Quantity Represented: 10 cu. yds. at 20 cu. yds. placed of a 20 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group r. Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. nLUnNcE # m GROUr Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 12/07/2010 Report Date: 01/05/2011 Previously Reported: 12/16/2010 Sampled By: Wingerd, Pierce Project: Sidewalk Improvements By Order Of: Larry Davis Location: Entrance into United Community Bank on Denton Tap. S. of Order Number: 1770 Sandy Lake Rd Number of Client: The City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 95634 Material: CONCRETE Test Method: See Below TEST RESULTS Report No: 95634 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (lbs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 67,965 Type 2 Lab 5,410 5,410 B 28 4.00 12.57 77,525 Type 3 Lab 6,170 C 28 4.00 12.57 78,045 Type 3 Lab 6,210 6,190 D HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Date Received: 12/08/2010 Slump: 4.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 3.6% Source /Sampled At: Truck / Center Time Sampled: 10:50 am Plant: Redi -Mix - Plant #259 Temp.: Ambient: 53 °F Mix: 61 °F Mix Code: 1 01_1 1504 Truck/Ticket No: 1375 / 25275848 Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.