Loading...
SW0801-LR110208GEOTECHNICRL GROur Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 01/28/2011 Report Date: 02/08/2011 Sampled By: Hickman, Brad Project: Sidewalk Improvements By Order Of: Larry Davis Location: Sidewalk @ 580 South DentonTap Rd. Order Number: 1770 43,365 Type 2 Lab 3,450 3,450 Number of 12.57 Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 97315 Material: Concrete Test Method: See Below TEST RESULTS Report No: 97315 Page 1 of 1 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM 0172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. (_arty Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF "I HE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (Ibs) Break Type Loc (PSI) (PSI) Comments A 7 4.00 12.57 43,365 Type 2 Lab 3,450 3,450 B 28 4.00 12.57 Lab C 28 4.00 12.57 Lab D HOLD (see remarks) - l ......... l I Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Slump: 4.5 Inches Transported By: Curing Method: Standard Air Content: 3.2% Source /Sampled At: Time Sampled: 1:50 pm Plant: Redi -Mix P259 Temp.: Ambient: 73 °F Mix: 60 °F Mix Code: 10J11504 Truck/Ticket No: 1289 / 25290109 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM 0172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. (_arty Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF "I HE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. GEOTEctimICRIL GROW Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Report Date: 02/08/2011 Project: Sidewalk Improvements Location: Approach @ 504 Denton Tap Client: City of Coppell Date Sampled: 01/31/2011 Sampled By: McDonald, Jack By Order Of: Larry Davis Order Number: 1770 Number of Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 97357 Material: Concrete Test Method: See Below TEST RESULTS Report No: 97357 Page 1 of 1 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 20 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138, Compressive strength tests per ASTM C39. Orig: The City of Copped (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nor (days) (in) (in') (Ibs) Break Type LOG (PSI) (PSI) Comments A 3 6.00 28.27 67,890 Type 1 Lab 2,400 2,400 B 7 6.00 2827 91,305 Type 5 Lab 3,230 3,230 C 28 6.00 28.27 Lab D 28 6.00 28.27 Lab II Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Slump: 4.5 Inches Transported By: Curing Method: Standard Air Content: 5.8% Source /Sampled At: Time Sampled: 1:30 pm Plant: Redi -Mix P136 Temp.: Ambient: 48 °F Mix: 65 °F Mix Code: 1 01_1 1504 Truck/Ticket No: 1189 / 25290812 Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 20 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138, Compressive strength tests per ASTM C39. Orig: The City of Copped (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.