Loading...
SW0801-LR110214GEOTECHNICRL 1 GR .. Acct ID: 1770 Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1036 Report Date: 02/14/2011 Previously Reported: 01/24/2011 Project: Sidewalk Improvements Location: Driveway approach to Texaco station, 55' W. x 10'S. of carwash, NW corner of bldg Date Sampled: 01/14/2011 Sampled By: Gatton, Tim By Order Of: Larry Davis Order Number: 1770 Quantity Represented: Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: City of Coppell (Coppell Tx) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FORTH E EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Number of Client: City of Coppell Specimens: 5 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 96849 Material: CONCRETE Test Method: See Below TEST RESULTS Report No: 96849 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in') (Ibs) Break Type Loc (PSI) (PSI) Comments A 3 6.00 28.27 94,565 Type 5 Lab 3,340 3,340 B 7 6.00 28.27 143,500 Type 6 Lab 5,080 C 7 6.00 28.27 146,440 Type 3 Lab 5,180 5,130 D 28 6.00 28.27 174,845 Type 2 Lab 6,180 E 28 6.00 28.27 170,240 Type 2 Lab 6,020 6,100 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Date Received: 01/15/2011 Slump: 4.5 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 3.2% Source /Sampled At: Truck/ Center Time Sampled: 1:55 pm Plant: Redi -Mix - Plant #P259 Temp.: Ambient: 47 °F Mix: 58 °F Mix Code: 101_11504 Truck/Ticket No: 1377 / 25285986 Quantity Represented: Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ATM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: City of Coppell (Coppell Tx) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FORTH E EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.