Loading...
Sales Tax 09-LR110223GEOTECHNUIL Acct ID: 1770 Report Date: 02/23/2011 Project: Clear Creek Location: STA 11 +25 Client: City of Coppell REPORT: Proctor Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1014 Previously Reported: 02/23/2011 Date Sampled: 02/19/2011 Sampled By: Jack McDonald By Order Of: Cruz Order Number: 1770 LAB NO: 97796 -1 TEST RESULTS Report No: Page 1 of 1 12 101 104 c 100 41 q) y O 96 92 88 84 t Moisture Content ( %) Group Symbol: CH AASHTO: A -7 -6(26) Atterberg Limits: LL = 54 PL = 21 PI = 33 Remarks: Test Method: ASTM D -698 Method -A Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. (1 -cc copy) 1 -cc City of Coppell Attn: Mr. Rick O'Dell 97796 -1 OMC, %: 21.0 MDD, pcf: 102.1 Description: Dark Brown Clay Desc. of Ram.: Mechanical Prep. Method: Dry Sieve % Passing No. 200 78 Respectfully Submitted, Alliance Geotechnical Group t z THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED VvITHOUT WRITTEN PERMISSION.