Loading...
SW0801-LR110223 (2)rru Acct ID: 1770 Consulting Engineering 'k Geotechnical Engineering � Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1036 Report Date: 02/23/2011 Project: Sidewalk Improvements Location: Sidewalk 600 S. Denton Tap Rd, at Denton Tap & Meadowcreek Client: Citv of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Date Sampled: 01/25/2011 Sampled By: Clay, Bill By Order Of: Larry Davis Order Number: 1770 Number of Specimens: 4 LAB NO: 97134 Material: CONCRETE Test Method: See Below TEST RESULTS Report No: 97134 Page 1 of 1 Spec Age Tested Nor (days) A 7 B 28 C 28 D Break Type HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: Compressive Maximum Cure Diameter Area Load (PSI) (in) (in') (lbs) Break Type 6.00 28.27 119,410 Type 2 6.00 28.27 136,715 Type 2 6.00 28.27 137,445 Type 2 HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: Compressive Average Cure Strength Strength Loc (PSI) (PSI) Comments Lab 4,220 4,220 Lab 4,840 Plant: Lab 4,860 4,850 HOLD (see remarks) - Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Date Received: 01/26/2011 Slump: 4.0 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 3.3% Source /Sampled At: Truck / Center Time Sampled: 9:15 am Plant: Redi -Mix - Plant #P259 Temp.: Ambient: 41 °F Mix: 58 °F Mix Code: 10J11504 Truck/Ticket No: 1349 / 25288256 Unit Weight: 144.6 # /cu ft Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, 0143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group f , Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL. OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. r - GROUff Acct ID: 1770 Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 File No: C10 -1036 Report Date: 02/23/2011 Project: Sidewalk Improvements Location: Sidewalks Client: City of Coppell REPORT: 2REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST Date Sampled: 01/26/2011 Sampled By: Gatton, Tim By Order Of: Larry Davis Order Number: 1770 LAB NO: 97191 Test Method: See Below TEST RESULTS Report No: 97191 Page 1 of 2 Set: 1 of 2 Material: CONCRETE Number of Specimens: 4 Location: Driveway approach exit side from Church and shopping center, 2' N. x 3' E. of centerline of curb Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (days) (in) (in 2) (Ibs) Break Type LOG (PSI) (PSI) Comments A 3 6.00 28.27 92,185 Type 2 Lab 3,260 3,260 B 7 6.00 28.27 116,805 Type 2 Lab 4,130 4,130 C 28 6.00 28.27 147,040 Type 4 Lab 5,200 D 28 6.00 28.27 142,395 Type 5 Lab 5,040 5,120 1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,600 psi @ 28 days Date Received: 01/27/2011 Slump: 4.5 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 4.3% Source /Sampled At: Truck / Center Time Sampled: 11:11 am Plant: Redi -Mix - Plant #P259 Temp.: Ambient: 60 °F Mix: 57 °F Mix Code: 10L11504 Truck /Ticket No: 1371 / 2528886 Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Ong: The City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. III GEOTECHMICIfIlL GR Consulting Engineering x Geotechnical Engineering " Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C10 -1036 Date Sampled: 01/26/2011 Report Date: 02/23/2011 Sampled By: Gatton, Tim Project: Sidewalk Improvements By Order Of: Larry Davis Location: Sidewalks Order Number: 1770 Client: City of Coppell REPORT: 2REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 97191 Test Method: See Below TEST RESULTS Report No: 97191 Page 2 of 2 Set: 2 of 2 Material: CONCRETE Number of Specimens: 4 Location: Sidewalk 4'N. & 5' E. of N. entrance to ReMax Realtors Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nor (days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) Comments A 7 6.00 28.27 110,195 Type 3 Lab 3,900 B 7 6.00 28.27 109,960 Type 2 Lab 3,890 3,890 C 28 6.00 28.27 131,160 Type 5 Lab 4,640 D 28 6.00 28.27 123,050 Type 5 Lab 4,350 4,500 f i ,ICI I h V_ If 1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Date Received: 01/27/2011 Slump: 4.5 Inches Transported By: Redi -Mix Curing Method: Standard Air Content: 4.0% Source /Sampled At: Truck / Center Time Sampled: 11:36 am Plant: Redi -Mix - Plant #P259 Temp.: Ambient: 60 °F Mix: 57 °F Mix Code: 1 01_1 1504 Truck /Ticket No: 1321 / 25288901 Quantity Represented: 10 cu. yds. Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: The City of Coppell (Coppell TX) Attn: Mr, Larry Davis (1 -cc copy) Respectfully Submitted, Alliance Geotechnical Group - Perry C. Kakara, Sr. Project Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.