Loading...
Tennis Ctr Exp-LR110307I nfot7m . on Professional Service Industries, Inc. 4087 Shilling Way Kevin Graham Field Methods: Dallas, TX 75237 �• T ]�l� � ASTM D 698 - 07 (A) No. F -03307 ®1Q1J[R Gauge Type: Phone: (214) 330t9211n EIKJfj}eEN/Nf CiOIISU�IIi� • [f 3430 Serial Number: 28352 Fax: (214) 333 -2853 Field Density Report Standard Count: Moisture: 652 Report No: FDR:03 1 Issue No: 1 Client: SCHMOLDT CONSTRUCTION CC: CARY SCHMOLDT These test results apply only to the specific locations and materials noted 5797 CR 126, SUITE A CHRIS HOUSE and may not represent any other locations or elevations. This report may CELINA, 75009 GEORGE MARSHAL not be reproduced, except in full, without written permission by Professional Service Industries, Inc. HILLARY WHITE JOHN ELIAS Project: COPPELL TENNIS CENTER JOHN FIELDER COPPELL TX LARRY DAVIS Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE Date of Issue: 3/7/2011 Testing Details Tested By: Kevin Graham Field Methods: ASTM D 6938 Lab Methods: ASTM D 698 - 07 (A) Date Tested: 3/2/2011 Gauge Type: Troxler Model Number: 3430 Serial Number: 28352 Test Mode: Direct Transmission Standard Count: Density: 1934 Standard Count: Moisture: 652 Test Results rest Material Depth of Test Wet Density Moisture Dry Density Relative Limit Vo (in) (lb/ft-) Content ( %) (lb/ft') Compaction M 1 Light Brown Sandy Clay 6 131.6 14.2 115.2 95.8 >_95 Location and Compaction rest Location MDD Soil ID MDD Method MDD (lb/ft-) OMC ( %) Vo 3eneral Location: Common Fill Area @ Washout on W -Side of Court 1 & 2 1 90'W of NW Corner of Court # 1 & 2, ELEV: FG 0341284 - 3 - S1 ASTM D 698 - 07 (A) 120.3 11.4 Comments Form No 110244.V1.00, Report No FDR:0341284 -52 (c) 2000 -2009 QESTLab by SpectraQEST.com Paae 1 of AFP% n 6 Irnnation F; TB & On EtV nsult ng • Tes#ing Concrete Test Report Client: SCHMOLDT CONSTRUCTION 5797 CR 126, SUITE A CELINA, 75009 Project: COPPELL TENNIS CENTER COPPELL, TX Professional Service Industries, Inc. 4087 Shilling Way Dallas, TX 75237 Texas Firm Registration No. F -03307 Phone: (214) 330 -9211 Fax: (214) 333 -2853 Report No: CON:0341284 -50 -C1 Issue No: 2 CC: CARY SC HMOLDT These test results apply only to the specific locations and materials noted CHRIS HOUSE and may not represent any other locations or elevations. This report may Measured Specified not be reproduced, except in full, without written permission by GEORGE MARSHAL Professional Service Industries, Inc. HILLARY WHITE 5.00 JOHN ELIAS Flatwork JOHN FIELDER 2270 LARRY DAVIS Sample Location Approved Signatory: Ronald Yeoman (Project Manager) LEE STONE 8.00 Date of Issue: 3/7/2011 Mix Data Supplier Lattimore Materials Mix Identification 5077 Specified Design Strength (psi) 3000 at age 28 days Details of Sample Date Sampled 1/29/2011 Date Received 1/31/2011 08:40 Measured Specified 08:40 Time In Truck (mins) Slump (in) ASTM C 143 5.00 General Location Flatwork Slump w/ plasticizer (in) 2270 N/A Sample Location 25'S X 10'E of NE Corner of Existing Building Air Temp ( °F) 8.00 45 Curing Method Two day Field /Laboratory Cure Concrete Temp ( °F) ASTM C 1064 55 Field Sample No Field Cure Temp ( °F) High Air Content (%) ASTM C 231 3.70 Low Unit Weight (pcf) ASTM C 138 3270 Contractor Batch Size (yd 3 ) 10 Truck No. 9140 Ticket No. 3288019 Water Added (gal) Before Sampled By Kilev Brown After Submitted By Weather Clear Est. Wind (mph) Yd Placed 20.0 Est. Rh ( %) Compressive Strength of Concrete Cylinders Specimen ID Date Tested Age Dimensions (in) Area (in 2) (days) Diameter Height Time Batched 07:55 Time Sampled 08:40 Time Placed 08:40 Time In Truck (mins) 45 ASTM C 39 Type of Ultimate Type of Compressive Required Cap Load (Ibf) Fracture Strength (psi) Strength (psi) 0341284 -50 -C1 \1 02/05/11 7 4.00 8.00 12.57 U 28800 2 2290 0341284- 50 -C1\2 02/05/11 7 4.00 8.00 12.57 U 28480 2 2270 0341284- 50 -C1 \3 02/26/11 28 4.00 8.00 12.57 U 41490 2 3300 3000 0341284 -50 -C1 \4 02/26/11 28 4.00 8.00 12.57 U 40670 2 3240 3000 Average 28 Day Compressive Strength (psi) 3270 Notes 1.Sampling to ASTM C 172 2.Specimen(s) Prepared to ASTM C 31 3.Capping B= Bonded ASTM C 617, U= Unbonded ASTM C 1231, C = Combined 0 : Remarks FailureMode: 2 = C39: Vert crack/ cone opposite end, C1314: Cone & Shear com Panes 1 of 1