Sales Tax 09-LR110304GEOTECHNICML
GROUr
Acct ID: 1770
Report Date: 03/04/2011
Project: Clear Creek
Location: Clear Creek Lane
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1014 Date Sampled: 03/02/2011
Sampled By: Hanks, Marvin
By Order Of: Rick O'dell
Order Number: 1770
Client: City of Coppell
REPORT: Lime Depth Verification LAB NO: 98114 -1
T est Me See B elow
TEST RESULTS Report No: 98114 -1
Page 1 of 1
A field representative for Alliance Geotechnical Group, checked the depth of lime treatment of the subgrade after
compaction. Depth measurements were performed using a phenolphthalein indicatior to verify compliance with project
specifications that require a minimum 6 in. compacted thickness. The test results follow.
Sample'
Depth,
No. L ocation
in.
1 49 Clear Cre Lane
6.7
2 !4 70 Clear Cree Lane -
-- - 7.00 — '
3 450 Clear Creek Lane
6.75
Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P. E. (1 -cc copy)
1 -cc City of Coppell Attn: Mr. Rick O'Dell
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED, THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.