PA0101-LR010410CONCRETE
COMPRESSIVE
STI~-NGTH
TEST
F~F~C~_I',~'.
8901 Carpenter Frwy., Suite
Report Number: 94011093.0005 n~.~. To_1~75247
Service Date: March 31, 2001 (214)
Client: City of Coppell- Parks & Recreation Report Date: ~i~ )ril 10, 2001 ·
Attn: Brad Reid Project: / Andrew Brown Park E~ st
732 DeForest Moore Road
Coppell TX 75019 Coppell, Texas
Project Numl~r: 94011093
Material Information Saml31e Inform'a~tion
Specified Strength: 3500 psi @ 28 Days Sample Time: 9:0Ua,[,
Technician: Roy Montgomery
Batch Time: 8:00am Plant: 41 .~-,, Weather Conditions:C~ar ,~/~
Supplier: TXI ~' ~ Accumula'~'ve Yards: 50 ~r~
Truck No: 837 Ticket N(~: ~AS/I 3'39 I~lacemer~ I~ ethoS. ~,~"
H
,, on
4+50
emer~ L~tion."'Paving Sta. 5+00 to Sta. 0+75
Field Test Data
Test Result Specification Test Method
Slump, inches: 4.50 3-5 ASTM C-143
Concrete Temperature, o F: 73 .ASTM C-39
Ambient Temperature, o F: 70
Plastic Unit Weight, pcf: ~r
LaboratorvTestData ~_ ~,,~
d Maximum Compressive
Set Specimen Diameter Dat~ ~ Load Strength
1 1 6.00 '~ 82,910 2,930
I 2 6.00 7 84,810 3,000
Average 2,970
I 3 04/28/2001 28
1 4 04/28/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shell not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested et the location(s) referenced and are net necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 3 ~'-LL,',,~' =,, ......
cONCRETE COMPRESSIVE STi~NGTH TEST --
EN( ill~..RIN[i. I'~'.
8g01 Carpenter Frwy., Suite #100
Report Number: g40110g3.0005 Danas, Texas 75247
Service Date: March 31,2001 (214) 63O-lOlO
Client: City of Coppell - Parks & Recreation Report Date: April 10, 2001
Attn: Brad Reid Project: Andrew Brown Park East
732 DeForest Moore Road
Coppell TX 75019 Coppell, Texas
Project Number: 94011093
Material Information Sample Information
Specified Strength: 3500 psi @ 28 Days Sample Time: 10:30am
Technician: Roy Montgomery
Batch Time: 9:30am Plant: 41 Weather Conditions:Clear
Supplier: TXI Accumulative Yards: 150
Truck No: 58 Ticket No: 2851425 Placement Method:
Mix I.D. No.: 8273 Sample Locations: Sta. 2+75
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.50 3-5 ASTM C-143
Air Content, %: ASTM C-172
Concrete Temperature, o F: 74 ASTM C-39
Ambient Temperature, o F: 73
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
2 1 6.00 04/07/2001 7 87,630 3,100
2 2 6.00 04/07/2001 7 83,670 2,960
Average 3,030
2 3 04/28/2001 28
2 4 04/28/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM. AASHTO. or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 3 c ..... ~ml ......
CONCRETE COMPRESSIVE STRENGTH TEST _
8901 Carpenter Frwy.. Suite #100
Report Number: 94011093.0005 Dallas, Texas 75247
Service Date: March 31,2001 (214) 63O-lOlO
Client: City of Coppell - Parks & Recreation Report Date: April 10, 2001
Attn: Brad Reid Project: Andrew Brown Park East
732 DeForest Moore Road
Coppell TX 75019 Coppell, Texas
Project Number: 94011093
Material Information Sample Information
Specified Strength: 3500 psi (~ 28 Days Sample Time: 11:45am
Technician: Roy Montgomery
Batch Time: 10:53am Plant: 41 Weather Conditions:Clear
Supplier: TXI Accumulative Yards: 250
Truck No: 58 Ticket No: 2851482 Placement Method:
Mix I.D. No.: 8273 Sample Locations: Station 1+25
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.25 3-5 ASTM C-143
Air Content, %: ASTM C-172
Concrete Temperature, o F: 79 ASTM C-39
Ambient Temperature, o F: 78
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
3 1 6.00 04/07/2001 7 81,410 2,880
3 2 6.00 04/07/2001 7 88,200 3,120
Average 3,000
3 3 04/28/2001 28
3 4 04128/2001 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Report Distribution:
(1) city of Coppell - Parks & Recreation
(1) TLB Construction Reviewed by:
(1) city of Coppell - Constr. Insp. Edc J. Cre, wland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 3 of 3 :, ~..,r~.-r.~,~ ~