Loading...
PA0101-LR010503 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0005 Dallas, Texas 75247 Service Date: March 31,2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: ~' ' Attn: Brad Reid ! Project: 732 DeForest Coppell TX 75019 ~' Project Number: Material Information Sample Information Specified Strength: 3500 psi @ 28 Days Sample Time: 9:00am Technician: Roy Montgomery Batch Time: 8:00am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 50 Truck No: 837 Ticket No: 2851339 Placement Method: Mix I.D. No.: 8273 Sample Locations: Station 4+50 Placement Location: Paving Sta. 5+00 to Sta. 0+75 Field Test Data Test Result Specification Test Method Slump, inches: 4.50 3-5 ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,o F: 73 ASTM C-39 Ambient Temperature, o F: 70 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 04/07/2001 7 82,910 2,930 1 2 6.00 04/07/2001 7 84,810 3,000 Average 2,970 1 3 6.00 04/28/2001 28 118,350 4,190 1 4 6.00 04/28/2001 28 121,060 4,280 Average 4,240 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 CONCRETE COMPRESSIVF- TRENGTH TEST 8901 Carpenter FnNy., Suite #100 Report Number: 94011093.0005 Dallas, Texas 75247 Service Date: March 31,2001 (214) 63o-1010 Client: City of Coppell - Parks & Recreation Report Date: May 03, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3500 psi @ 28 Days Sample Time: 10:30am Technician: Roy Montgomery Batch Time: 9:30am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 150 Truck No: 58 Ticket No: 2851425 Placement Method: Mix I.D. No.: 8273 Sample Locations: Sta. 2+75 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.50 3-5 ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,o F: 74 ASTM C-39 Ambient Temperature, 0 F: 73 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 2 1 6.00 04/07/2001 7 87,630 3,100 2 2 6.00 04/07/2001 7 83,670 2,960 Average 3,030 2 3 6.00 04/28/2001 28 104,650 3,700 2 4 6.00 04/28/2001 28 117,370 4,150 Average 3,930 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical materials. Page 2 of 3 CONCRETE COMPRESSIVE--'RENGTH TEST 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0005 Dallas, Texas 75247 Service Date: March 31,2001 (214) 63O-lOlO Client: City of Coppell - Parks & Recreation Report Date: May 03, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Saml~le Information Specified Strength: 3500 psi @ 28 Days Sample Time: 11:45am Technician: Roy Montgomery Batch Time: 10:53am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 250 Truck No: 58 Ticket No: 2851482 Placement Method: Mix I.D. No.: 8273 Sample Locations: Station 1+25 Placement Location: See page Field Test Data Test Result Specification Test Method Slump, inches: 5.25 3-5 ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,o F: 79 ASTM C-39 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: Laboratorv Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 3 1 6.00 04/07/2001 7 81,410 2,880 3 2 6.00 04/07/2001 7 88,200 3,120 Average 3,000 3 3 6.00 04/28/2001 28 129,860 4,590 3 4 6.00 04/28/2001 28 128,480 4,540 Average 4,570 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Roy Montgomery Report Distribution: (1) City of Coppell - Parks & Recreation (1) TLB Construction Reviewed by: (1) City of Coppell - Constr. Insp. Eric J. Cleveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 ~1~w~1~