Loading...
ST0702-LR100303 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 174.0104 Teri, ; ., k en Service Date: 02/24/10 8901 Carpenter Frwy. Report Date: 03/03/10 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Colwell TX Coppell Road - #ST07 -02 Attn: Rick O'DeII Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9475 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi ® 28 days Sample Date: 02/24/10 Sample Time: 1110 Sampled By: Francisco J. Morillo Mix ID: I OL 1 1504 Weather Conditions: Clear Supplier: Redi -Mix Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 0953 Plant: 259 Placement Method: Direct Discharge Truck No.: 1349 Ticket No.: 25165594 Water Added Before (gal):10 Field Test Data Water Added After (gal): 0 Sample Location: See Placement Location Test Result Specification Placement Location: Pavement, Crosswalk on Burns Street Slump (in): 4 3 -5 and Coppell Road Air Content ( %): 4.0 3 -6 Concrete Temp. (F): 55 • Ambient Temp. (F): 46 Plastic Unit Wt. (pct): 145.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. I D (in) (sq in) Received Tested (days) (lbs) (psi) Type I 1 6.00 28.27 02/25/10 03/01/10 5 124,170 4,390 4 1 2 6.00 28.27 02/25/10 03/03/10 7 136,900 4,840 4 1 3 6.00 28.27 02/25/10 03/24/10 28 1 4 6.00 28.27 02/25/10 03/24/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast ompressive strength samples. Terracon Rep.: Francisco J. Morillo Started: 1000 .// Reported To: Superintendent Finished: 1230 Contractor: JR.I Paving Report Distribution: (1) Cily or Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) ,Irt.1 Paving 1.1' Eric J. 1 eland, P.E. Senior Pr. ect Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 1 (-Room. ;.� i -u,, uce.. sw CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0096 rerr, a • Service Date: 02/17/10 8901 Carpenter Frwy. Report Date: 03/03/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Sample Date: 02/17/10 Sample Time: 0925 Sampled By: Jose A. Martinez Mix ID: 1701 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 40 Batch Size (cy): 10 Batch Time: 0836 Plant: 3 Placement Method: Direct Discharge Truck No.: 7008 Ticket No.: 3273841 Water Added Before (gal):0 Field Test Data Water Added After (gal): 0 Sample Location: Sample #1; see attached sketch Test Result Specification Placement Location: Future Retail Parking; see attached Slump (in): 5 3 -5 sketch Air Content ( %): 7.0 3 -6 Concrete Temp. (F): 48 Ambient Temp. (F): 41 Plastic Unit Wt. (pcf): 138.8 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 02/18/10 02/24/10 7 116,320 4,110 4 1 2 6.00 28.27 02/18/10 03/03/10 14 125,320 4,430 2 1 3 6.00 28.27 02/18/10 03/17/10 28 1 4 6.00 28.27 02/18/10 03/17/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Jose A. Martinez Reported To: Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc (1) JRJ Paving LP Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CR0001, 5.21 -09, Rev.) CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0096 lrerr c .,' ,„ , Service Date: 02/17/10 8901 Carpenter Frwy. Report Date: 03/03/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Sample Date: 02/17/10 Sample Time: 1059 Sampled By: Jose A. Martinez Mix ID: 1701 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 110 Batch Size (cy): 10 Batch Time: 1014 Plant: 3 Placement Method: Direct Discharge Truck No.: 7037 Ticket No.: 3273852 Water Added Before (gal):10 Field Test Data Water Added After (gal): 0 Sample Location: Sample #2; see attached sketch Test Result Specification Placement Location: Future Retail Parking; see attached Slump (in): 5 1/4 3 -5 sketch Air Content ( %): 6.4 3 -6 Concrete Temp. (F): 54 Ambient Temp. (F): 46 Plastic Unit Wt. (pcf): 139.8 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 2 1 6.00 28.27 02/18/10 02/24/10 7 115,150 4,070 2 2 2 6.00 28.27 02/18/10 03/03/10 14 123,050 4,350 2 2 3 6.00 28.27 02/18/10 03/17/10 28 • 2 4 6.00 28.27 02/18/10 03/17/10 28 Comments: Notified JRJ Paving LP about high air content. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Jose A. Martinez Reported To: Ai, Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP Eric J. ' eveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 CR0001, 5.21.09, Rev.l TERRACO? REPORT NO. � i Z r //� PROJECT: C o p DD2I J 1) U c / c )_ - 1 7 1 PROJECT NO.: 9 40 9 / 1 7 'I ` d 096 1F erracor , y S, Consulting Engineers & Scientists 1� N P a Z � N F r 'fi . k k.: ',h 4 1 �. 5. t9,- 1 %fii, - - c3 ";,1 . 4?4, - : '-vi....1 ) J - : } P „ , 1.,. ,' •y i y � ° :`: ,Il q .. •. 1 1 J r 4, J .,,,Z• :',4..`10:. It • '.1 : •... • --)