Loading...
ST0702-LR100305 CONCRETE COMPRESSIVE STRENGTH TEST REPORT , Report Number: 94091174.0093 8,- Service Date: 02/05/10 8901 Carpenter Frwy. Report Date: 03/05/10 Revision 2 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,200 psi @ 28 days Sample Date: 02/05/10 Sample Time: 1130 Sampled By: Burl E. Thomas Mix ID: 1701 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 6.5 Batch Size (cy): 6.5 Batch Time: 1024 Plant: 3 Placement Method: Direct Discharge Truck No.: 9105 Ticket No.: 3273707 Water Added Before (gal):0 Water Added After (gal): 0 Field Test Data Sample Location: Sta. 8 +79, Sta. 8 +81 Test Result Specification Placement Location: Inlet curb, N Gutter, Coppell Road Slump (in): 3 Air Content ( %): 4.5 Concrete Temp. (F): 56 Ambient Temp. (F): 50 Plastic Unit Wt. (pcf): 150.8 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (Ibs) (psi) Type 1 1 6.00 28.27 02/06/10 02/12/10 7 145,620 5,150 4 1 2 6.00 28.27 02/06/10 02/19/10 14 155,400 5,500 2 1 3 6.00 28.27 02/06/10 03/05/10 28 173,530 6,140 4 1 4 6.00 28.27 02/06/10 03/05/10 28 178,920 6,330 4 Average (28 days) 6,240 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and ca .compres iv strength samples. Terracon Rep.: Burl E. Thomas Started: 0830 Reported To: Finished: 1300 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: (1) JRJ Paving LP l Eric J. Clrel.t d, P.E. Senior Projec Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CR000I, 5- 2I -09, Rev.3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091174.0100 , iiy 4 ii,,,, Service Date: 02/19/10 8901 Carpenter Frwy. Report Date: 03/05/10 Revision 1 Dallas, TX 75247 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 3,600 psi @ 28 days Sample Date: 02/19/10 Sample Time: 0926 Sampled By: Jose A. Martinez Mix ID: 1701 Weather Conditions: Cloudy, windy Supplier: Lattimore Accumulative Yards: 20 Batch Size (cy): 10 Batch Time: 0854 Plant: 7 Placement Method: Direct Discharge Truck No.: 7060 Ticket No.: 7214744 Water Added Before (gal):5 Water Added After (gal): 0 Field Test Data Sample Location: Coppell Road - North crossing at Burns Test Result Specification Placement Location: Pavement Slump (in): 4 3 -5 Air Content ( %): 7.2 3 -6 Concrete Temp. (F): 56 Ambient Temp. (F): 47 Plastic Unit Wt. (pet): 141.7 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (Ibs) (psi) Type 1 1 6.00 28.27 02/20/10 02/26/10 7 95,630 3,380 5 1 2 6.00 28.27 02/20/10 03/05/10 14 109,630 3,880 4 1 3 6.00 28.27 02/20/10 03/19/10 28 1 4 6.00 28.27 02/20/10 03/19/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Jose A. Martinez Started: 0830 Reported To: Finished: 1130 Contractor: JRJ Paving Report Distribution: (1) City of Coppell TX (1) Freese and Nichols Inc Reviewed By: j 0) IRJ Paving LP '. IC" C e eland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CR0001, 5- 21.09, Rev.3 PROJECT: C �� e. (1 T ��et a 15'/0 PROJECT NO.: C I '1°7 // 74' 0 (o0 ' a Consulting Engineers & Scientists TER' , CON REPORT NO. 9 // 7, 0/0'0 y// 9 //n • __a • • (( l V o O C") ZocA A e L L I