ST0702-LR100324 CONCRETE COMPRESSIVE STRENGTH TEST REPORT ! Ir Report Number: 94091174.0104 Service Date: 02/24/10 8901 Carpenter Frwy. Report Date: 03/24/10 Revision 1 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Coppell Road - #ST07 -02 Attn: Rick O'Dell Bethel Road to Engineering Dept Southwestern Blvd. PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94091174 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 02/24/10 Sample Time: 1110 Sampled By: Francisco J. Morillo Mix ID: 10L11504 Weather Conditions: Clear Supplier: Redi -Mix Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 0953 Plant: 259 Placement Method: Direct Discharge Truck No.: 1349 Ticket No.: 25165594 Water Added Before (gal):10 Water Added After (gal): 0 Field Test Data Sample Location: See Placement Location Test Result Specification Placement Location: Pavement, Crosswalk on Burns Street Slump (in): 4 3 -5 and Coppell Road Air Content ( %): 4.0 3 -6 Concrete Temp. (F): 55 Ambient Temp. (F): 46 Plastic Unit Wt. (pcf): 145.0 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 02/25/10 03/01/10 5 124,170 4,390 4 1 2 6.00 28.27 02/25/10 03/03/10 7 136,900 4,840 4 1 3 6.00 28.27 02/25/10 03/24/10 28 190,620 6,740 2 1 4 6.00 28.27 02/25/10 03/24/10 28 190,710 6,750 4 Average (28 days) 6,750 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressiv 'rength samples. Terracon Rep.: Francisco J. Morillo Started: 1000 Reported To: Superintendent Finished: 1230 Contractor: JRJ Paving Report Distribution: Reviewed By: (1) City of Coppell TX (I) Freese and Nichols Inc (1) JRJ Paving LP Eric . Cleveland, P.E. Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 CR0001, 5.21 -09, Rev .3