ST0702-LR100301 CONCRETE COMPRESSIVE STRENGTH TEST REPORT
Report Number: 94091 174.0102 lierracon
Service Date: 02/22/10 8901 Carpenter Frwy.
Report Date: 03/01/10 Dallas, TX 75247
214- 630 -1010 Reg No: F -3272
Client Project
City of Colwell TX Coppell Road - #ST07 -02
Attn: Rick O'Dell Bethel Road to
Engineering Dept Southwestern Blvd.
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94091174
Material Information Sample Information .
Specified Strength: 4,000 psi @ 28 days Sample Date: 02/22/10 Sample Time: 1145
Sampled By: Julio R. Perez
Mix ID: 1701 Weather Conditions: Cloudy
Supplier: Lattimore Accumulative Yards: 5.5 Batch Size (cy): 5.5
Batch Time: 1 102 Plant: 07 Placement Method: Direct Discharge
Truck No.: 50 Ticket No.: 7214796 Water Added Before (gal):5
Field Test Data Water Added After (gal): 0
Sample Location: Coppell Road and Burns
Test Result Specification Placement Location: Inlet
Slump (iii): 3
Air Content ( 3.5
Concrete Temp. (F): 65
Ambient Temp. (F): 43 .
Plastic Unit Wt. (pcf): 143.2 •
Laboratory Test Data Age at Maximum Compressive
Set Specimen Diameter Area Date Date Test Load Strength Fracture
No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type
1 1 6.00 28.27 02/23/10 03/01/10 7 151,610 5,360 2
1 2 6.00 28.27 02/23/10 03/08/10 14
1 3 6.00 28.27 02/23/10 03/22/10 28 •
1 4 6.00 28.27 02/23/10 03/22/10 28
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast compressive streigth
samples.
Terracon Rep.: Julio R. Perez Started: 1000
Reported To: Finished: 1300
Contractor: .IR.I Paving .
Report Distribution:
(1 ) City or Comet! TX (I) Freese and Nichols Inc Reviewed By:
(1).1R.1 Paving LP 'ric Itev land, P.E.
Senior Proje t Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
Page 1 of 1
CR(NNII. 3.21 -119, Rent