Loading...
ST0701-LR100310 FIELD DENSITY TEST REPORT T F n r Report Number: 94091 194.0044 � ii , ' ��w 1 - Service Date: 03/04/10 8901 Carpenter Frwy. Report Date: 03/10/10 Dallas, TX 75247 214 -630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creek to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Lab Test Data Project Requirements • Optimum Max. Lab Water Dry Unit Water Minimum Mat. Proctor Laboratory Content Weight Content Compaction No. Rcl'. No. Classification and Description Test Method ( %) (pcf) ( %) ( %) 1 9409 193.0055 Dark gray clay (lime treated) ASTM D698 38.2 79.1 -2/ +4 95 Field Test Data Probe Wet Water Water Dry Unit Percent Test Lift / Mat. Depth Density Content Content Weight Compaction No. Test Location Elev. No. (in) (pcf) (pcf) ( %) (pcf) ( %) Paving, Eastbound Lane 53 Sta. 30+10 Final 1 6 108.2 29.5 37.5 78.7 99 54 Sta. 31+70 Final 1 6 111.5 29.7 36.3 81.8 103 55 Sta. 33+50 Final 1 6 107.3 29.8 38.5 77.5 98 56 Sta.35 +10 Final 1 6 110.5 29.9 37.1 80.6 102 Gauge ID: 1960 Comments: Test results on this report meet project requirements as noted above. Services: Perform in -place density and moisture content tests to determine degree of compaction and ma - rial oisture condition. ,/ Terracon Rep.: [carry Coble Started: 1400 Reported To: Marcos, Lacy Finished: 1530 Contractor: Lacy Construction ; r Report Distribution: j' (1) PacTrust Pacific Realty Associates 1.1' (1) City of Coppell TX Reviewed By: % ; /. (1) Ci y of Coppell TX (2) Raiff Assoc Inc Eric J.(Cleveland, P.E. (1) Lacy Con :unction, Senior Project Manager Test Methods: ASTM D6938 • The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 rlt110u7.1- :0-119, Rev