SW0801-LR110328Consulting Engineering x Geotechnical Engineering X Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID:
1770 File No: C10 -1036
Date Sampled: 03 /18/2011
Report Date: 03/28/2011
Sampled By:
Mitchell, David
Project:
Sidewalk Improvements
By Order Of:
Larry Davis
Location:
Sidewalk at S.bound Denton Tapp ; 280' N. of Bethel School Rd
Order Number:
1770
(PSI) (PSI) Comments
A 03/25/11
Number of
12.57
Client:
City of Coppell
Specimens:
4
REPORT:
REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO:
98647
Material:
CONCRETE
Test Method:
See Below
TEST RESULTS Report No: 98647
Page 1 of 1
Quantity Represented: 20 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173,
C1064 and C138, Compressive strenqth tests per ASTM C39.
O rig : City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
r
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive Average
Spec Age Tested
Diameter
Area
Load Cure
Strength Strength
Nbr (date : days)
(in)
(in 2)
(Ibs) Break Type Loc
(PSI) (PSI) Comments
A 03/25/11
:7 4.00
12.57
40,460 Type 1 Lab
3,220 3,220
B 04/15/11 :28
4.00
12.57
Lab
C 04/15/11:28
4.00
12.57
Lab
D
HOLD (see remarks) -
-
i
Type 1
Type 2 Type 3 Type 4
Type 5 Type 6
Specification:
3,000 psi @ 28 days
Date Received:
03/19/2011
Slump: 5.0 Inches
Transported By: Redi -Mix
Curing Method:
Standard
Air Content: 3.0%
Source /Sampled At: Truck / Center
Time Sampled.
12:20 pm
Plant: Redi -Mix - Plant #P259
Temp.: Ambient:
79 °F Mix: 75 °F
Mix Code: 10J11504
Truck/Ticket No: 1383 / 25306305
Quantity Represented: 20 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173,
C1064 and C138, Compressive strenqth tests per ASTM C39.
O rig : City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
r
Perry C. Kakara, Sr. Project Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.