PA9901-LR001018 _ ONCRETE COMPRE .DIVE STRENGTH TES 1 ENGINEERING, INC. a division of 1r@rracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date Date of Service: 09/15/2000 Report No.: 0024171 10/18/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 09/15/2000 BATCH TIME: 11 :OOa PLANT: 29 TIME SAMPLED: 1 1 :45a BY: Chris Eubanks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny STRENGTH: 3500 psi @ 28 Days TEMPERATURE (F) - AIR 90 F CONCRETE: 85 F SLUMP: 3 -5" TRUCK NO: 1880 TICKET NO: 663874 AIR: 3 -7% AIR CONTENT ( %): 6.5 UNIT WEIGHT (pct): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: Fence pole bases and entrance to dugout on Fields #1 and #2 ASTM C -172 ASTM C -39 SAMPLE LOCATION: See below for location REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.50 09/22/2000 7 71320 2520 1 2 5.50 09/22/2000 7 69920 2470 Average 2500 1 3 5.50 10/13/2000 28 103100 3650 1 4 5.50 10/13/2000 28 99860 3530 Average 3590 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. oils Page 1 of 2 7tport No.: 0024171 Sample Location: Pole base and entrance to dugout on N side of Field #1 Technician: Chris Eubanks Started: 10:30a Finished: 2:OOp , { . P 4,4. eer , Inc. Report Distribu g (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. Olss Page 2 of 2