PA9901-LR000921 CONCRETE COMPRt ,SIVE STRENGTH TES i Plr ENGINEERING, INC. a division of l 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 09/12/2000 Report No.: 0023815 Report Date 09/21/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Co ell, Texas Carrollton TX 75006 pp Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 09/12/2000 BATCH TIME: 1 1:27am PLANT: 27 TIME SAMPLED: 11:45am BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Cloudy STRENGTH: 3500 psi @ 28 Days TEMPERATURE (F) - AIR 90 F CONCRETE: 94 F SLUMP: 4.0" Max TRUCK NO: 924 TICKET NO: 687182 AIR: 3 -5 %p AIR CONTENT ( %): 3.4 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: Flat work- sidewalk & pad area around concession building (See attached sketch) ASTM C -172 ASTM C -39 Sampled from truck. SAMPLE LOCATION: 10' S of Bldg. REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 4.50 09/19/2000 7 82320 2910 1 2 4.50 09/19/2000 7 84810 3000 Average 2960 1 3 4.50 10/10/2000 28 1 4 4.50 10/10/2000 28 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. OILL Page 1 of 2 CONCRETE COMPRt SIVE STRENGTH TES ENGINEERING, INC. a division of 1Cerracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 09/12/2000 Report No.: 0023815 Report Date 09/21/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 09/12/2000 BATCH TIME: 12:4Opm PLANT: 27 TIME SAMPLED: 1:2Opm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Cloudy STRENGTH: 3500 psi @ 28 Days TEMPERATURE (F) - AIR 89 F CONCRETE: 94 F SLUMP: 4.0" Max TRUCK NO: 1020 TICKET NO: 687189 AIR: 3 -5% AIR CONTENT ( %): 4.1 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 See page 1 ASTM C -39 Sampled from pump. SAMPLE LOCATION: 15' N of bldg. REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 2 1 5.00 09/19/2000 7 92170 3260 2 2 5.00 09/19/2000 7 91090 3220 Average 3240 2 3 5.00 10/10/2000 28 2 4 5.00 10/10/2000 28 Technician: Greg Dimock Started: 10:30am Finished: 3:30pm r ip . Report Distribution: ngineering, Inc. (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 2 of 2 //0e pp 4 I" kr 0 1 ' /r 3 i ° jh I ( I , i C' 1 - Vt. ' -so w l PI \ NI/ A LA pp 1 v4ato 0