Loading...
PA9901-LR000710 IN -PLACE DENSITY TASTING fir ENGINEERING, INC. a division of 1Ferracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06/24/2000 Report No.: 0016600 Report Date 07/10/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: In -place density testing. PROJECT DATA CONTRACTOR: Laboratory Test Method: Field Test Method: Hisaw ASTM D -698 ASTM D2922 ASTM D3017 MOISTURE DENSITY RELATIONS: Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Med brown sandy clay 15.0 112.0 -1/ +3% 95% 2 Lt. brown & tan clayey sand 13.0 116.0 -1/ +3% 95% FIELD DENSITY TESTS TEST PROBE LIFT / M/D MOISTURE DRY DENSITY DENSITY NO TEST LOCATION DEPTH ELEV No. ( %) (pcf) (% max) Pond Retaining Wall 83 SW Quadrant, E side 1st 1 14.2 107.4 96 84 SW Quadrant, N side 1st 1 15.7 107.0 96 85 NW Quadrant, E side 1st 1 15.8 106.8 95 86 NE Quadrant on center line 1st 1 17.2 108.3 97 87 SE Quadrant, N side 1st 2 14.1 111.0 96 88 SE Quadrant on center line 1st 2 14.4 114.3 99 Test results on this report meet project specification. • :.• ering, Inc. Technician: Phil Green Started: 1:OOp Finished: 2:30p Report Distribution: (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07SDS Page 1 of 1 IN -PLACE DENSITY TL3TING Fir ENGINEERING, INC. a division of lrerracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 06/28/2000 Report No.: 0016957 Report Date 07/10/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: In -place density testing. PROJECT DATA CONTRACTOR: Laboratory Test Method: Field Test Method: Hisaw ASTM D -698 ASTM D2922 ASTM D3017 MOISTURE DENSITY RELATIONS: Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Lt. brown & tan clayey sand 12.0 116.0 -1/ +3% 95% FIELD DENSITY TESTS TEST PROBE LIFT / M/D MOISTURE DRY DENSITY DENSITY NO TEST LOCATION DEPTH ELEV No. ( %) (pcf) (% max) Pond Retaining Wall 89 SW Quadrant, E side 2nd 1 12.4 112.6 97 90 SW Quadrant, N side 2nd 1 11.1 110.8 96 91 NW Quadrant, E side 2nd 1 11.7 111.6 96 92 NE Quadrant, W side 2nd 1 11.2 110.9 96 93 SE Quadrant, N side 2nd 1 13.0 112.4 97 Test results on this report meet project specification. 177 ? Technician: Phil Green Started: 10:00a Finished: 11:30a Bering, Inc. Report Distribution: (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07SDS Page 1 of 1