Loading...
PA9901-LR000620 CONCRETE COMPREL, IVE STRENGTH TES l j� ENGINEERING, INC. a division of l fe rracan 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date Date of Service: 05/22/2000 Report No.: 0013519 06/20/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 44 CONCRETE SUPPLIER: Lattimore PLACEMENT DATE: 05/22/2000 BATCH TIME: 2:34pm PLANT: 7 TIME SAMPLED: 3:10pm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 95 F CONCRETE: 89 F SLUMP: 5.0" Max TRUCK NO: 958 TICKET NO: 7087372 AIR: 3 -5 %p AIR CONTENT ( %): 3.6 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C-143 PLACEMENT LOCATION: Inlets at S firelane one (1) at E end & one (1) at W end ASTM C -172 ASTM C -39 Sampled from truck. Technician Time: See Report #0013511 SAMPLE LOCATION: Inlet at E end REPORT OF TESTS ACCUMULATIVE YARDS: 3 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE 1 1 3.25 05/29/2000 7 88200 3120 1 2 3.25 05/29/2000 7 84810 3000 Average 3060 1 3 3.25 06/19/2000 28 119580 4230 1 4 3.25 06/19/2000 28 114720 4060 Average 4150 Technician: Greg Dimock Started: Finished: / r ng Inc. Report Distribution: (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 1 of 1 CONCRETE COMPRE,SIVE STRENGTH TES. Eil_ ENGINEERING, INC. a division of-Wei-aeon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 _ Date of Service: 05/22/2000 Report No.: 0013511 Report Date 06/20/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 05/22/2000 BATCH TIME: 11:34am PLANT: 29 TIME SAMPLED: 12:OOpm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 90 F CONCRETE: 89 F SLUMP: 5.0" Max TRUCK NO: 80 TICKET NO: 535125 AIR: 3 -5% AIR CONTENT ( %): 4.2 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: Paving- S parking lot -pour #2 ASTM C -172 ASTM C -39 Sampled from truck. SAMPLE LOCATION: 40' E of W joint & 10' N of S curb REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.25 05/29/2000 7 97790 3460 1 2 5.25 05/29/2000 7 100350 3550 Average 3510 1 3 5.25 06/19/2000 28 114520 4050 1 4 5.25 06/19/2000 28 117260 4150 Average 4100 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of NBC Engineering, Inc. 01LL Page 1 of 4 CONCRETE COMPRE,JSIVE STRENGTH TES. I - 13C ENGINEERING, INC. a division of lFerracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 05/22/2000 Report No.: 0013511 Report Date 06/20/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA • CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 05/22/2000 BATCH TIME: 12:47pm PLANT: 29 TIME SAMPLED: 1:15pm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 90 F CONCRETE: 90 F SLUMP: 5.0" Max TRUCK NO: 80 TICKET NO: 535132 AIR: 3 -5% AIR CONTENT ( %): 4.3 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: See page 1 ASTM C -172 ASTM C -39 Sampled from pump. SAMPLE LOCATION: 80' E of W joint & 5' N of S curb REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE 2 1 5.00 05/29/2000 7 79130 2800 2 2 5.00 05/29/2000 7 84810 3000 Average 2900 2 3 5.00 06/19/2000 28 96120 3400 2 4 5.00 06/19/2000 28 98030 3470 Average 3440 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 2 of 4 CONCRETE COMPRE.,SIVE STRENGTH TES ENGINEERING, INC. a division of 1rerracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 05/22/2000 Report No.: 0013511 Report Date 06/20/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX 1.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 05/22/2000 BATCH TIME: 2:45pm PLANT: 29 TIME SAMPLED: 3:3Opm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 92 F CONCRETE: 89 F SLUMP: 5.0" Max TRUCK NO: 1824 TICKET NO: 567968 AIR: 3 -5% AIR CONTENT ( %): 4.0 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 See page 1 ASTM C -39 Sampled from pump. SAMPLE LOCATION: 130' E of W joint & 3' N of S curb REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 3 1 5.50 05/29/2000 7 95860 3390 3 2 5.50 05/29/2000 7 97240 3440 Average 3420 3 3 5.50 06/19/2000 28 114820 4060 3 4 5.50 06/19/2000 28 111670 3950 Average 4010 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. O1LL Page 3 of 4 CONCRETE COMPRE,_3IVE STRENGTH TES, lir ENGINEERING, INC. a division of 1 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 05/22/2000 Report No.: 0013511 Report Date 06/20/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 05/22/2000 BATCH TIME: 4:OOpm PLANT: 29 TIME SAMPLED: 4:3Opm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATIIER CONDITIONS: Clear STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 96 F CONCRETE: 91 F SLUMP: 5.0" Max TRUCK NO: 648 TICKET NO: 535144 AIR: 3 -5% AIR CONTENT ( %): 4.7 UNIT WEIGIIT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: See page 1 ASTM C -172 ASTM C -39 Sampled from pump. SAMPLE LOCATION: 50' W of E joint & 5' N of S curb REPORT OF TESTS ACCUMULATIVE YARDS: CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 4 1 4.75 05/29/2000 7 80150 2830 4 2 4.75 05/29/2000 7 83670 2960 Average 2900 4 3 4.75 06/19/2000 28 92320 3260 4 4 4.75 06/19/2000 28 102770 3630 Average 3450 r Technician: Greg Dimock Started: Finished: it Report Distribution: Engineering, Inc. .."1 (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. OILL Page 4 of 4