PA9901-LR000601 CONCRETE COMPREL 3IVE STRENGTH TES _ Fir
ENGINEERING, INC.
a division of l
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
Date of Service: 05/24/2000 Report No.: 0013775 Report Date
06/01/2000
Client No.: 36503000 Project No.: 94001043
Client: Hisaw & Associates Project: Wagon Wheel Park
Attn: Bill Morgan 154 S. State Road
3116 Kellway Dr., Suite 116
Carrollton TX 75006 Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast
compressive strength samples.
PROJECT DATA
CONTRACTOR: Hisaw MIX I.D.: 44
CONCRETE SUPPLIER: Lattimore PLACEMENT DATE: 05/24/2000 BATCH TIME: 2:24pm
PLANT: 3 TIME SAMPLED: 3:1Spm BY: Greg Dimock
SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear
STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 93 F CONCRETE: 90 F
SLUMP: 5.0" Max TRUCK NO: 1096 TICKET NO: 104642
AIR: 3 -6% AIR CONTENT ( %): 3.8 UNIT WEIGHT (pcf): N/A
TEST METHOD: ASTM C -143 PLACEMENT LOCATION:
Inlets- 2 @ S end of project & 1 @ N end
ASTM C -172
ASTM C -39 Sampled from truck.
Technician Time: See Report #0013725
SAMPLE LOCATION: SW inlet
REPORT OF TESTS ACCUMULATIVE YARDS: 7
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE
1 1 4.75 05/31/2000 7 103180 3650
1 2 4.75 05/31/2000 7 100350 3550
Average 3600
1 3 4.75 06/21/2000 28
1 4 4.75 06/21/2000 28
Technician: Greg Dimock Started: Finished:
r'-gin ing, Inc.
Report Distribution:
(1) Hisaw & Associates
(1) City of Coppell - Engineering Dept. ric J. Cleveland, P.E.
Senior Project Engineer
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc.
OILL Page 1 of 1