Loading...
PA9901-LR000522 CONCRETE COMPRE,,SIVE STRENGTH TES ENGINEERING, INC. a division of 1I rracon 8901 Carpenter Frwy., Suite #100 ••■ Dallas, Texas 75247 Date of Service: 04/20/2000 Report No.: 0010578 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 7:OOam PLANT: 27 TIME SAMPLED: 7:4Sam BY: Shane Spinks SPECIFIChTION REQUIREMENTS WEATHER CONDITIONS: Sunny, windy, mild STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 64 F CONCRETE: 68 F SLUMP: 3 -5" TRUCK NO: 653 TICKET NO: 506112 AIR: 3 -5% AIR CONTENT ( %): 4.2 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: Paving southside of parking lot ASTM C -172 ASTM C -39 SAMPLE LOCATION: See below REPORT OF TESTS ACCUMULATIVE YARDS: 50 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.00 04/27/2000 7 89520 3170 1 2 5.00 04/27/2000 7 84820 3000 Average 3090 1 3 5.00 05/18/2000 28 115610 4090 1 4 5.00 05/18/2000 28 116180 4110 Average 4100 Sample location: 12' North x 280' east of southwest corner of parking lot This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 1 of 6 CONCRETE COMPRELI IVE STRENGTH TES ... I-PC ENGINEERING, INC. a division of 1l rracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/20/2000 Report No.: 0010578 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 8:1Sam PLANT: 27 TIME SAMPLED: 8:SOam BY: Shane Spinks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny, windy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 66 F CONCRETE: 70 F SLUMP: 3 -5" TRUCK NO: 653 TICKET NO: 506123 AIR: 3 -5% AIR CONTENT (%): 3.8 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: See page 1 ASTM C -172 ASTM C -39 SAMPLE LOCATION: See below REPORT OF TESTS ACCUMULATIVE YARDS: 140 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTIL FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 2 1 5.25 04/27/2000 7 85240 3010 2 2 5.25 04/27/2000 7 87140 3080 Average 3050 2 3 5.25 05/18/2000 28 126030 4460 2 4 5.25 05/18/2000 28 120930 4280 Average 4370 Sample location: 15' N x 350' E of SW corner of parking lot This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 2 of 6 CONCRETE COMPRE,,LIVE STRENGTH TES ENGINEERING, INC. a division of lrerracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/20/2000 Report No.: 0010578 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 9:3 lam PLANT: 27 TIME SAMPLED: 10:25am BY: Shane Spinks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny, windy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 67 F CONCRETE: 71 F SLUMP: 3-5" TRUCK NO: 710 TICKET NO: 506133 AIR: 3 -5% AIR CONTENT ( %): 4.1 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 South firelane ASTM C -39 SAMPLE LOCATION: 20' N x 320' E of SW corner REPORT OF TESTS ACCUMULATIVE YARDS: 200 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 3 1 4.75 04/27/2000 7 106900 3780 3 2 4.75 04/27/2000 7 106500 3770 Average 3780 3 3 4.75 05/18/2000 28 139030 4920 3 4 4.75 05/18/2000 28 141330 5000 Average 4960 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. OILL Page 3 of 6 CONCRETE COMPRELJ IVE STRENGTH TES,, HE ENGINEERING, INC. a division of lrerracorl 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/20/2000 Report No.: 0010578 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 11:OSam PLANT: 27 TIME SAMPLED: 12:2Opm BY: Shane Spinks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny, windy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 72 F CONCRETE: 73 F SLUMP: 3 -5" TRUCK NO: 879 TICKET NO: 506147 AIR: 3 -5% AIR CONTENT ( %): 3.8 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 South firelane ASTM C -39 SAMPLE LOCATION: 20' N x 380' E of SW corner REPORT OF TESTS ACCUMULATIVE YARDS: 290 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 4 1 5.25 04/27/2000 7 101220 3580 4 2 5.25 04/27/2000 7 100350 3550 Average 3570 4 3 5.25 05/18/2000 28 136570 4830 4 4 5.28 05/18/2000 28 140210 4960 Average 4900 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. O1LL Page4of6 CONCRETE COMPRE ,SIVE STRENGTH TES _ fir ENGINEERING, INC. a division of 1I rracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/20/2000 Report No.: 0010578 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Co ell, Texas Carrollton TX 75006 pp Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 12:45pm PLANT: 27 TIME SAMPLED: 2:OOpm BY: Shane Spinks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny, mild STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 75 F CONCRETE: 73 F SLUMP: 3-5" TRUCK NO: 923 TICKET NO: 506160 AIR: 3 -5% AIR CONTENT ( %): 3.3 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: South firelane ASTM C -172 ASTM C -39 SAMPLE LOCATION: 20' N x 440' E of SW corner REPORT OF TESTS ACCUMULATIVE YARDS: 340 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 5 1 5.00 04/27/2000 7 91380 3230 5 2 5.00 04/27/2000 7 94130 3330 Average 3280 5 3 5.00 05/18/2000 28 119710 4230 5 4 5.00 05/18/2000 28 119290 4220 Average 4230 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. O1LL Page 5 of 6 CONCRETE COMPRE,,SIVE STRENGTH TES ENGINEERING, INC. a division of 1 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date Date of Service: 04/20/2000 Report No.: 0010578 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Co ell, Texas Carrollton TX 75006 PP Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw Mix I.D.: 9339 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/20/2000 BATCH TIME: 1:27pm PLANT: 27 TIME SAMPLED: 2:SOpm BY: Shane Spinks SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Sunny, windy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 77 F CONCRETE: 75 F SLUMP: 3 -5" TRUCK NO: 1831 TICKET NO: 514005 AIR: 3 -5% AIR CONTENT (%): 3.6 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 South firelane ASTM C -39 SAMPLE LOCATION: 20' N x 500' E of SW corner REPORT OF TESTS ACCUMULATIVE YARDS: 400 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 6 1 5.25 04/27/2000 7 78480 2780 6 2 5.25 04/27/2000 7 75320 2660 Average 2720 6 3 5.25 05/18/2000 28 101710 3600 6 4 5.25 05/18/2000 28 102050 3610 Average 3610 Technician: Shane Spinks Started: 6:OOam Finished: 4:OOpm 01 V Report Distribution: /777 ; ' : Ineering, Inc. (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. Eric J. Cleveland, P.E. Senior Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 6 of 6 CONCRETE COMPRE, . SIVE STRENGTH TES_ HE ENGINEERING, INC. a division of 1! rracon 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/19/2000 Report No.: 0010439 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9333 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/19/2000 BATCH TIME: 11:5Oam PLANT: 22 TIME SAMPLED: 12:2Opm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Partly cloudy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 77 F CONCRETE: 84 F SLUMP: 5.0" Max TRUCK NO: 653 TICKET NO: 531018 AIR: 3 -6% AIR CONTENT (%): N/A UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C-172 South firelane and parking ASTM C -39 Sampled from pump. SAMPLE LOCATION: 12' E of W joint & 20' N of S curb REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.00 04/26/2000 7 88430 3130 1 2 5.00 04/26/2000 7 84810 3000 Average 3070 1 3 5.00 05/17/2000 28 113650 4020 1 4 5.00 05/17/2000 28 116180 4110 Average 4070 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 1 of 2 CONCRETE COMPRP_SIVE STRENGTH TES ___ HE ENGINEERING, INC. a division of lferracan 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 04/19/2000 Report No.: 0010439 Report Date 05/22/2000 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park Attn: Bill Morgan 154 S. State Road 3116 Kellway Dr., Suite 116 Carrollton TX 75006 Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Hisaw MIX I.D.: 9333 CONCRETE SUPPLIER: Pioneer PLACEMENT DATE: 04/19/2000 BATCH TIME: 3:46pm PLANT: 22 TIME SAMPLED: 4:3Opm BY: Greg Dimock SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Partly cloudy STRENGTH: 3000 psi @ 28 Days TEMPERATURE (F) - AIR 73 F CONCRETE: 82 F SLUMP: 5.0" Max TRUCK NO: 653 TICKET NO: 534040 AIR: 3 -6% AIR CONTENT ( %): 4.5 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C -143 PLACEMENT LOCATION: ASTM C -172 See page 1 ASTM C -39 Sampled from pump. SAMPLE LOCATION: 75' E of W joint & 5' S of N curb REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 2 1 4.25 04/26/2000 7 125880 4450 2 2 4.25 04/26/2000 7 131350 4650 Average 4550 2 3 4.25 05/17/2000 28 151020 5340 2 4 4.25 05/17/2000 28 159730 5650 Average 5500 Technician: Greg Dimock Started: 10:30am Finished: 5:30pm e Report Distribution: lineering, Inc. (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. ',Eri- J. Cleveland, P.E. S- or Project Engineer This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01LL Page 2 of 2