Loading...
PA9901-LR000308 ENVIRONMENTAL. ' TECHNICAL AND CONSTRUCTION M IALS SERVICES March 8, 2000 Hisaw & Associates 3116 Callaway Drive, Suite 116 Carrollton, Texas 75006 ENGINEERING, INC. Attn: Mr. Bill Morgan a division of 1 rerracon Re: Moisture Evaluation No. 1 Wagon Wheel Park Coppell, Texas HBC Project No. 94001043 Gentlemen: HBC Engineering, Inc. (HBC) has completed its first evaluation of moisture levels achieved by water pressure injection at the above referenced site. The concession area was injected with 4 passes of water and the two ancillary building areas were injected with 5 passes of water prior to this evaluation. HBC personnel observed the injection process on a full -time basis. A total of 6 borings were drilled on February 28, 2000. Each boring was continuously sampled to a depth of 10 feet with thin - walled tubes. The samples were extruded, logged, sealed, and packaged at the site for transportation to the laboratory. In the laboratory, moisture content and hand penetrometer readings were determined on one -foot intervals. A diagram depicting the boring locations is attached. Laboratory data is provided on the attached Summary of Laboratory Tests. A review of the moisture content determinations and hand penetrometer tests indicates that the moisture contents across the concession pad are significantly below the desired moisture levels. Borings 5 and 6 for the ancillary buildings contained significant amounts of sands and clayey sands. In these areas, it is NBC's recommendation that the select fill be placed as soon as possible to minimize the loss of moisture in the soils prior to placement of the slab. However, in the concession area, it is HBC's recommendation that the building pad be retested after receiving two additional water injections. Please contact us if there are any questions concerning the test results or recommendations. Sincerely, HBC ENGINEERING, INC. / ( Bryan S. Moulin Project Ma r nan A. P well, P.E. Project Engineer cc: City of Coppell- Engineering Dept. (1) Houston Dallas Fort Worth Austin Wichita Falls 11555 Clay Road 8901 Carpenter Frwy. 2301 E. Loop 820 North 3913 Todd Lane 3100 Seymour Hwy. Suite 100 Suite 100 Flagstone & Loop 820 Suite 312 Suite 105 Houston, TX 77043 Dallas, TX 75247 Fort Worth, TX 76118 Austin, TX 78744 Wichita Falls, TX 76310 (713) 690-8989 (214) 630-1010 (817) 268-8600 (512) 442 -1122 (940) 766 -6092 PAY (7111 (4!1.5757 Fav 0)141 A111_7(1711 Pow (517) 7�5 (1 P,.. / 'O AA, 11Q r., i�nrn occ <nm a O a N w 7 11116 1 z z __ T....7 y B -1 1 B -2S B - 3� B-4 / O O 0 40 80 FEET APPROXIMATE SCALE 8 -6 B-5 0 15 30 FEET APPROXIMATE SCALE NOTE: BORING LOCATIONS ARE APPROXIMATE BORING LOCATION DIAGRAM MOISTURE EVALUATION No. 1 WAGON WHEEL PARK COPPELL, TEXAS HBC ProJoct No.. 94001043 Date. 03/03/00 T MC MOISTURE URE EVALUATION NO. 1 ENGINEERING, INC SUMMARY OF LABORATORY TESTS PROJECT NAME: Wagon Wheel Park Coppell, Texas PROJECT NO.: 94001043 DATE: 3/3/00 Boring Depth Percent Hand Number (feet) Moisture Penetrometer B -1 0 -1 15 4.5+ 1 -2 15 4.3 2 -3 15 4.5+ 3 -4 16 4.5+ 4 -5 17 4.5+ 5 -6 17 4.5+ 6 -7 20 4.5+ 7 -8 19 4.5+ 8 -9 18 4.5+ 9 -10 15 4.5+ B -2 0 -1 14 4.5+ 1 -2 23 2.5 2 -3 30 2.0 3 -4 23 3.5 4 -5 21 4.5+ 5 -6 21 4.5+ 6 -7 21 4.5+ 7 -8 21 4.5+ 8 -9 16 4.5+ 9 -10 13 4.5+ B -3 0 -1 18 4.0 1 -2 14 4.5+ 2 -3 16 4.5+ 3 -4 19 4.5+ 4 -5 20 4.5+ 5 -6 20 4.5+ 6 -7 20 4.5+ 7 -8 20 4.5+ 8 -9 20 4.5+ 9 -10 19 4.5+ AT FBC MOISTURE EVALUATION ION N O. 1 ENGINEERING, INC SUMMARY OF LABORATORY TESTS PROJECT NAME: Wagon Wheel Park Coppell, Texas PROJECT NO.: 94001043 DATE: 3/3/00 Boring Depth Percent Hand Number (feet) Moisture Penetrometer B -4 0 -1 31 - -- 1 -2 16 3.8 2 -3 19 4.0 3 -4 23 1.8 4 -5 24 2.0 5 -6 23 2.8 6 -7 23 3.5 7 -8 22 4.5 8 -9 16 4.5+ 9 -10 16 4.5+ B -5 0 -1 16 2.3 1 -2 13 1.5 2 -4 11 - -- 4-5 12 - -- 5-6 14 - -- 6-7 7 4.5+ 7 -8 9 4.5+ 8 -9 8 4.5+ 9 -10 7 4.5+ B -6 0 -1 16 3.5 1 -2 17 4.5+ 2 -3 12 4.5+ 3 -4 5 4.5+ 4 -5 4 - -- 5-6 4 - -- 6-7 4 - -- 7-8 3 - -- 8 -10 3 - --