Loading...
PA9901-LR000217 WATER INJECTION OBSERVATION FBC ENGINEERING, INC. 8901 Carpenter Freeway, Suite 100 Dallas, Texas 75247 Date of Service: 02/17/00 Report No.: 0004838 Client No.: 36503000 Project No.: 94001043 Client: Hisaw & Associates Project: Wagon Wheel Park 3116 Callaway Dr, Suite 116 154 S. State Road Carrollton, TX 75006 Coppell, Texas Location: Concession Stand and Restroom General Contactor: Hisaw and Pump Pad and Service B Injector: Kenneth Moore Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this site. During the injection process, the following observations were recorded. Pass No.: 1st and 2nd No. of Probes: 4 Probe Length: 11 feet OBSERVATION SPECIFICATION Yes No N/A Surfactant added to each load. X Injection pressure 50 to 200 psi at manifold. X Injection downward in 18 inch intervals. X Total depth of injection was 10 feet. X Spacing of injection was 5 feet maximum. X Injection to refusal at each location. X Comments: Only able to penetrate 3 feet on Pump Pad. Technician: C. Williams/T. Smith Started: 7:00 a.m. Stopped: 1:30 p.m. Report Distribution: 1 Engin • ering, Inc. (1) Hisaw & Associates (1) City of Coppell - Engineering Dept. 471 "I'iC J. Cleveland, P.E. Senior Project Engineer 99dp This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of HBC Engineering, Inc.