PA9901-LR000216 WATER INJECTION OBSERVATION
ENGINEERING, INC.
8901 Carpenter Freeway, Suite 100
Dallas, Texas 75247
Date of Service: 02/16/00 Report No.: 0004548
Client No.: 36503000 Project No.: 94001043
Client: Hisaw & Associates Project: Wagon Wheel Park
3116 Callaway Dr, Suite 116 154 S. State Road
Carrollton, TX 75006 Coppell, Texas
Location: Service and Well Buildings and General Contactor: Hisaw
Restroom and Concession Stand Injector:
Procedure: On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 1st No. of Probes: 4 Probe Length: 10 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
Injection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
Injection to refusal at each location. X
Comments: Both Service and Well Buildings were only penetrating 4 feet instead of 8 feet.
Technician: M. Villanueva Started: 10:00 a.m. Stopped: 5:30 p.m.
Report Distribution: �. ! • /. ' ng, Inc.
(1) Hisaw & Associates
(1) City of Coppell - Engineering Dept.
A/1
Eric J. Cleveland, P.E.
Senior Project Engineer