Loading...
ST9902-CS030205 PROJECT SCOPE ITEMS SANDY LAKE – FREEPORT PARKWAY TO DENTON TAP ST 99-02B PAVEMENT AND ALIGNMENT TOPICS PAVEMENT SECTION PAVING DESIGN CRITERIA City of Coppell Construction Design Standards & North Central Texas Council of Governments Standard Specifications for Public Works Construction ROW WIDTH: Existing: Varies from 55’ to 120’ Proposed: 90’ minimum PAVEMENT WIDTH: Existing: 24’ Proposed: 2 – 27’ back to back No. of lanes proposed: 4 lanes PARKWAY: Proposed Width: Varies – 10’ minimum Proposed Sidewalk Width: Sidewalks are 5’ & hike and bike trail is 10’ Parkway cross fall slope maximum: 3”/ft. GRADE REQUIREMENTS: Is TC below adjacent ground criteria to be followed? No Any deep cuts, high fills? Yes PAVEMENT CROSS FALL: PROPOSED: ¼”/ft. MINIMUM: ¼”/ft. MAXIMUM: ¼”/ft. 1 PROJECT SCOPE ITEMS Sandy Lake – Freeport Pkwy To Denton Tap (ST 99-02B) VERTICAL GRADE: MINIMUM: 0.5% MAXIMUM: 5.13% CENTERLINE ALIGNMENT POSITION: IN CENTER OF EXISTING ROW? No OFFSET FROM CENTER: Varies ON BRAND NEW ALIGNMENT? No LEFT TURN LANES: 15 left turn lanes MINIMUM LENGTH: 155.5’ MINIMUM STORAGE: 60’ WIDTH: 10’ _____ ANY DUAL LEFT TURN LANES? YES NO X ANY FREE RIGHT TURN LANES? YES One @ Denton Tap _____ NO _____ CRASH CUSHIONS / ATTENTUATORS INVOLVED YES NO X _____ RAILROAD CROSSINGS INVOLVED YES NO X NOTE: IF CURRENT CROSSING IS NOT USED, IS ABANDONMENT AN _____ OPTION? YES _____ NO 2 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) PAVEMENT STRUCTURE DESIGN WHEEL LOAD: 18 kip single axle load BUS AND HEAVY TRAFFIC: YES X ____ NO _ ROADWAY CLASSIFICATION: Major arterial MINIMUM PAVEMENT STRUCTURE THICKNESS: 8” MINIMUM PAVEMENT BASE OR SUBGRADE THICKNESS: 8” DESIGN SPEED: 50 MPH (40 MPH @ Coppell Road North Intersection & 45 MPH @ Coppell Road South Intersection) POSTED : 35 MPH MEDIANS MEDIAN WIDTH: 16’ _____ ANY MID BLOCK OPENINGS TO CONSIDER? YES NO X ANY SIDE STREETS TOO CLOSE FOR OPENING? YES X (Branchwood Drive & Georgian Lane) _____ NO STANDARD TURN LANE WIDTH: 11’ min. & 12’ max. STANDARD NOSE WIDTH: 6’ 3 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) DRIVEWAYS: MAXIMUM RESIDENTIAL GRADE: ¾”/ft. MAXIMUM COMMERCIAL GRADE: ¾”/ft. MINIMUM COMMERCIAL DRIVEWAY WIDTH: 20’ / 15’ one way SIDE STREET CONSIDERATIONS TURNING RADIUS, MINIMUM: 35’ major / 25’ residential and minor Streets PAVEMENT THICKNESS: 8” COMMERCIAL DRIVEWAY THICKNESS: 6” DRAINAGE TOPICS STORM SEWER DESIGN CRITERIA: TxDOT ________ CITY City of Dallas Drainage Design Criteria HYDRO-35 X TP-40 ________ INLET DEPTHS (APPROPRIATE FOR PAVEMENT THICKNESS) 4 ½’ MINIMUM COVER LATERALS 2’ below subgrade BRIDGES/BOX CULVERTS INVOLVED YES X _____ NO 100 YEAR FLOOD PLAIN CONSIDERATION yes / 2 FT FREEBOARD 4 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) PERMITS COE 404 PERMITS NEEDED YES may be required because of the creek crossing and construction of new bridge NO _____ TNRCC 401 PERMIT YES may be required as part of 404 NO _____ CDC PERMIT YES _____ NO X ADA PERMIT YES X (If > $50,000 of pedestrian facilities) _____ NO ANY OTHER PERMITS FROM OTHER AGENCIES SUCH AS TxDOT, DFW, AIRPORT, DART, ETC? YES (Plans will be submitted to the Texas Historical Commission – may need permit if it is determined that any archaeological sites are in the vicinity of the project ) _____ NO UTILITIES LIST OF ALL KNOWN UTILITES: 1.Southwestern Bell 4. AT&T Broadband 2.Oncor Gas & Electric 5. Metromedia Fiber Network 3.Verizon 6. Touch America DOCUMENT KNOWN RISKS ( TRA lines, Transmission Towers, Lone Star Gas Valve Stations) FOR OUR UTILITY PARTNERS: Oncor transmission towers – street alignment moved to south to miss large towers ARE UTILITIES ON EXISTING STREET R.O.W.? Yes DO UTILITIES OWN THEIR R.O.W. OR HAVE PREVIOUS EASEMENTS? Oncor has 40’ utility easement HAS WORK ORDER BEEN ISSUED FOR SUE (Subsurface Utility Engineering)? No ANY SPECIAL CONSIDERATIONS? No 5 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) R-O-W ACQUISITION RIGHT- OF- WAY CONSTRAINTS, IF ANY, PROVIDE A LIST AND DESCRIPTION ALONG WITH DATA FOR RISK ASSESSMENT: Many of the newer residential developments have dedicated right-of-way to accommodate the roadway widening. In addition, they have utility, landscape, and open space easements established beyond the right-of-way dedication. In the case of most older subdivisions, individual properties, and undeveloped tracts, the existing right-of-way is not sufficient for the proposed widening. There does not appear to be any right-of-way constraints. ANY NON-ROUTINE, i.e., CEMETARY, JUNK YARD, OLD CHURCHES, SERVICE STATIONS, CONTAMINATED SOILS, LANDFILLS, NOISE WALL CONSIDERATIONS, TRAILER PARKS, TREE ORDINANCES? YES ______ NO X ANY NON-CONFORMING ISSUES? YES _____ NO X R-O-W MAP NEEDED YES Completed NO _____ FIELD NOTES NEEDED YES Completed NO _____ R-O-W PLATS NEEDED YES X NO _____ RELOCATION ASSISTANCE INVOLVED YES _____ NO X PARKING/LOSS OF PARKING CONSIDERATIONS YES _____ NO X HISTORICAL SITE CONSIDERATION YES _____ NO X 6 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) USUAL CITY TOPICS OF CONCERN DESIGN STANDARDS TO BE USED? City of Coppell Design Standards & NCTCOG ORDER OF PRECEDENCE OF STANDARDS. City of Coppell Design Standards & NCTCOG AUXILIARY LANES? None PROVISIONS FOR FUTURE WIDENING? No LANDSCAPING? Under separate contract – Parks and Recreation Department EXPOSED AGGREGATE DRIVEWAYS, SIDEWALKS? No STAMPED/COLORED CONCRETE? Yes IRRIGATION? Yes BRICK PAVERS? Yes STREET LIGHTING? Streetlights will be placed in the median. Installation of the foundations and conduit are included as part of the construction. Oncor will perform the actual streetlight installation. TRAFFIC SIGNALS? At the Coppell Road North and Coppell Road South intersections PAVEMENT MARKINGS? Yes BIKE LANES (EXTRA WIDTH)? Outer lane is 14.5’ & a separate 10’ hike & bike trail NEW SIDEWALKS? Yes DART BUS TURNOUTS? No BUS STOPS OR BUS SHELTERS? No WATER UTILITY BETTERMENTS? No WATER UTILITY RELOC.? Yes SAN. SEWER BETTERMENTS? No SAN. SEWER RELOC.? Yes 7 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkwy To Denton Tap (ST 99-02B) RETAINING WALLS? Proposed decorative stacked-block retaining wall system (STONE, BLOCKS, GABIONS, PROPRIETARY TYPES) SOD, SEEDING, TOPSOIL? Yes DRAINAGE IMPROVEMENTS? Enclosed drainage system improvements & bridge RR CROSSING IMPROVEMENTS? No GRADE SEPARATIONS? No RAMPS OR CONNECTORS TO TxDOT FACILITIES? No SPECIAL SCHOOL OR EMERGENCY VEHICLE CONSIDERATIONS ANY NEARBY OR ADJACENT SCHOOLS, CITY HALL, FIRE OR POLICE DEPARTMENT REQUIRING SPECIAL CONSIDERATION? No PUBLIC INVOLVEMENT CITY COUNCIL APPROVAL OF ALIGNMENT, REQUIRED? YES X approval of preliminary plans and award of construction contract NO _____ HAVE ALL NEIGHBOR GROUPS PROVIDED EARLY INPUT? YES _____ project will be broken into two sections, Freeport Pkwy. To Coppell Road, and Coppell Road to Denton Tap - citizen input will be solicited NO X for the Coppell Road to Denton Tap section NEIGHBORHOOD MEETINGS REQUIRED? not required, but will be conducted YES _____ NO X IF REQUIRED WHO CONDUCTS, CITY OR COUNTY? City DOCUMENT POTENTIAL SITES FOR PUBLIC AND OR NEIGHBORHOOD MEETINGS. The meetings will be conducted at City Hall, located at 255 Parkway Boulevard 8 PROJECT SCOPE ITEMS Sandy Lake – Freeport Parkway To Denton Tap (ST 99-02B) CONSTRUCTIBILITY REPORT FROM INSPECTION STAFF, DOCUMENT ANY AND ALL ISSUES THAT MAY AFFECT PROJECT SCOPE, BUDGET, CONSTRUCTIBILITY, THE PROJECT SCHEDULE AND/OR THE SAFETY OF PROJECT. The east half of West Sandy Lake Road, from Freeport Parkway to Denton Tap Road is almost completely developed with residential subdivisions. Right-of-way will be required on both sides of the existing roadway. The existing irrigation and landscaping adjacent to the right-of-way, and currently maintained by an HOA, is an issue that will have to be addressed. Four of the smaller Oncor electric transmission poles will need to be relocated. They are located within an exclusive Oncor easement and the relocation will be an expense of the City. There are overhead power lines on the south side of Sandy Lake and five buried power line crossing that will need to be relocated. There is an overhead power line on the north side of the roadway that will need to be relocated. There are several buried lines that feed off of this line that will need to be evaluated. There is a high-pressure 24-inch gas line that crosses the roadway that may require lowering. There are gas distribution lines on both the north and south sides of the roadway that will need to be relocated. Access across construction areas will need to be provided throughout all phases of construction. Temporary pavement will be needed to accommodate construction and allow the existing roadway to remain in use. Most intersections will need to be constructed in phases to facilitate continuous access to and from Sandy Lake Road. Access to private drives will also have to be maintained. The interconnect system of the proposed traffic signals will need to be addressed. Tree removal from Coppell Road to Denton Tap will be a major issue. 9