Willow Park-LR110602 Rone Engineering 7701 8908 Ambassador Row, Dallas, TX 75247 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630 -9745 Report of Concrete Compressive Strength Test Client: JR Rose Development Companies I Report No.: 391499 1207 Bethel School Court Coppell, TX 75019 ! / Project No.: 1116815 Date of Service: 05/25/2011 J ii/e Report Date: 06/02/2011 Project: Willow Park Townhomes Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Mix Design I.D.: D10000001103 Measured Concrete Supplier: Southern Star Placement Date: 05/25/2011 Slump Plant: 125 Weather Conditions: Sunny (inches) Specification Requirements Time Sampled: 12:10pm Batch time: 11:37am 3.0 Strength: 4,200 psi @ 28 days Temperature - Air: 76 °F Concrete: 80 °F Slump (in.): 3" - 5" Truck No: 3444 Ticket No: 1837578 Air ( %): 3.5% - 6% Air Content: 4.4% Unit Weight (pcf): NA Test Method: ASTM C -172 Overall Placement Location: ASTM C -31 (except 10.1.2) Manhole at existing manhole #2 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 Sample Location: l ASTM C -1231 Same as above 4 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in (Ibs) (psi) Type 1 1 06/01/2011 7 6.00 28.27 97,810 3,460 Type 5 1 2 06/22/2011 28 1 3 06/22/2011 28 1 4 07/20/2011 56 M Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Remarks: Water added at site: 6 gallons Technician: Heath Tally Started: 11:30am Finished: 01:15pm Rone Engineering Report Distribution: Orig: JR Rose Development Companies (Coppell, TX) Attn: Mr. Jason Rose (1 -ec copy) , , f 1 -ec Rone Project Manager Attn: Mr. Jason Creasy AET ' 1 -ec City of Coppell Attn: Mr. Mike Garza Jason Creasy, AET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM /JC) Page 1 of 1