Loading...
ST9301-LR060119 Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 „: Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 248793 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 01/11/2006 Coppell TX 75019 Report Date: 01/19/2006 Project: East Sandy Lake Road ST 93 -01 // 1)1) 59 2 25 Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Gauge: Troxler 3430 Standard Counts Test Methods: ASTM D - 2922 Moisture Density ASTM D -3017 Gauge Serial No: 33438 Current: 569 Current: 2571 Test Mode: DT Previous: 571 Previous: 2564 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Clayey Sand w /trace sandstone 14.0 113.0 Optimum +5 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcf) (pct) (% max) Wall backfill 1 Sandy Lake Road, 45' left, Station 42 +60, 6" 1 14.7 125.2 109.2 97 elevation 450 Wall backfill 2 Sandy Lake Road, 43' left, Station 43 +50, 6" 1 14.7 126.2 110.0 97 elevation 450 Wall backfill 3 Sandy Lake Road, 41' left, Station 43 +80, 6" 1 14.1 127.4 111.7 99 elevation 450 Test results on this report meet project specification. / Technician: Julio Perez Started: 12:30p Finished: 2:00pm Cali � � 0 mem 1g Report Distribution: lif i , � (1) City of Coppell / _ / (I) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd )7TM Page 1 of 1 Ron e Engineering n e e r n /"y 8908 Ambassador Row, Dallas, TX 75247 ® VV 1 1 i.r 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 248848 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 01/12/2006 Coppell TX 75019 Report Date: 01/19/200 Project: East Sandy Lake Road C, ST 93 -01 ` �%1 Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Gauge: Troxler 3430 Standard Counts Test Methods: ASTM D -2922 Moisture Density ASTM D -3017 Gauge Serial No: 33438 Current: 580 Current: 2562 Test Mode: DT Previous: 569 Previous: 2571 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Silty Sand w/ Sandstone & Gravel 11.0 98.0 Optimum +4 98 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pct) (pcf) (% max) Wall backfill 1 Sandy Lake Road, 45' left, Station 42 +00, 6" 1 13.1 110.2 97.4 99 elevation 443.83 Wall backfill 2 Sandy Lake Road, 42' left, Station 42 +00, 6" 1 13.5 110.8 97.6 100 elevation 443.83 Wall backfill 3 Sandy Lake Road, 40' left, Station 41 +10, 6" 1 13.1 110.6 97.8 100 elevation 445.84 Wall backfill 4 Sandy Lake Road, 44' left, Station 42 +10, 6" 1 13.1 110.4 97.6 100 elevation 445.84 Test results on this report meet project specification. Technician: Julio Perez Started: 10:00a Finished: R Orir e (fi 1:OOpm Report Distribution: : rr (1) City of Coppell (1) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. )7TM Page 1 of 1