ST9301-LR060208 8908 Ambassador Row, Dallas, TX 75247 r n 1 Engineering 2696 Gravel Drive, Fort Worth, TX 76118 `.. 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 250034 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 01/30/2006 Coppell TX 75019 Report Date: 02/08/2006 Project: East Sandy Lake Road , , ,0 �� ST 93 -01 ‘ W' �� Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN I.D.: 1703 MEASURED SLUMP CONCRETE SUPPLIER: LMC PLACEMENT DATE: 01/30/2006 (inches) PLANT: 3 WEATHER CONDITIONS: Clear 4.25 SPECIFICATION REQUIREMENTS TIME SAMPLED: 10:27am BATCH TIME: 9:41 am STRENGTH: 3600 psi @ 28 Days TEMPERATURE (F) - AIR 61 F CONCRETE: 67 F SLUMP (in): 4" maximum TRUCK NO: 1096 TICKET NO: 3208177 AIR ( %): NA AIR CONTENT ( %): NA UNIT WEIGHT (pct): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 except 9.1.2 South box culvert, Sandy Lake Road and Silver Leaf ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: 8' east from west end ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 02/06/2006 7 6.00 28.26 99240 3510 Unbonded Cap 1 2 02/27/2006 28 0.00 0.00 Unbonded Cap 1 3 02/27/2006 28 0.00 0.00 Unbonded Cap 1 4 Hold Water added at site: 5 gallons Technician: Ken Brimingham Started: 9:OOam Finished: 11:15am ly ? "�� = �'` ' — may Report Distribution: kji—Ift � (1) City of Coppell _ _ (1) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 01SS Page l of 1