Loading...
ST9301-LR051212 'Zone Engineering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 246583 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 12/02/2005 Report Date: , 12/12/2005 WV Project: East Sandy Lake Road ()yl i1 * L -WCA4 1 ST 93 -01 Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 Moisture Density ASTM D - 2922 ASTM D -3017 Gauge Serial No: 35519 Current: 691 Current: 2562 Test Mode: DT Previous: 678 Previous: 2586 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Clayey Sand w /trace sandstone 14.0 113.0 Optimum +4 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pct) (pcf) (% max) Retaining wall 1 Sandy Lake Road, Station 25 +75, final 6" 1 14.9 128.5 111.8 99 Retaining wall 2 Sandy Lake Road, Station 28 +00, final 6" 1 14.4 128.2 112.1 99 Test results on this report meet project specification. Technician: Julio Perez Started: 7 :30am Finished: 9:15am 4 » i►1/ ' Report Distribution: 1 AT 4 r ' (1) City of Coppell 0 it (1) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07SS Page 1 of 1 iEngneering 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 245143 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 11/10/2005 Coppell TX 75019 Report Date: 12/12/2005 Project: East Sandy Lake Road lNJ * 6 8 ST 93 -01 Z Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MEASURED CONTRACTOR: Tiseo Paving Company MIX DESIGN I.D.: 9363 SLUMP CONCRETE SUPPLIER: Southern Star PLACEMENT DATE: 1 1/10/2005 (inches) PLANT: 27 WEATHER CONDITIONS: Cloudy 5.0 SPECIFICATION REQUIREMENTS TIME SAMPLED: 1 1:40am BATCH TIME: 10:47am STRENGTH: 4000 psi @ 28 Days TEMPERATURE (F) - AIR 61 F CONCRETE: 78 F SLUMP (in): 5" maximum TRUCK NO: 1015 TICKET NO: 1013487 AIR ( %): 4% - 6% AIR CONTENT ( %): 5.3 UNIT WEIGHT (pcf): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 Stamped concrete, intersection of Sandy Lake Road and Subdivision Road except 9.1.2 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: Westbound lane ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 1 1 11/17/2005 7 6.00 28.26 81430 2880 Unbonded Cap 1 2 12/08/2005 28 6.00 28.26 114210 4040 Unbonded Cap 1 3 12/08/2005 28 6.00 28.26 126400 4470 Unbonded Cap Average 4260 1 4 Hold / Technician: Lanny Gist S tarted: 1 0:15am F inished: 1 2:30pm �yt ' ' � Report Distribution: r! "- / (1) City of Coppell (1) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. ft1CC Page 1 of 1