IN -PLACE DENSITY TESTING
Client: City of Coppell Report No.: 246812
Ms. Suzan Taylor Project No.: 059909
PO Box 9478 Date of Service: 12/06/2005
Coppell TX 75019 Report Date: 12/15/2005
Project: East Sandy Lake Road i.n D a
ST 93 01 i ) W '1
Services: Perform In -Place Density Test in accordance with ASTM Standards. V
PROJECT DATA
CONTRACTOR: Tiseo Paving Company Gauge: Troxler 3430 Standard Counts
Test Methods: ASTM D -2922 Moisture Density
ASTM D -3017 Gauge Serial No: 35519 Current: 688 Current: 2594
Test Mode: DT Previous: 691 Previous: 2562
MOISTURE DENSITY RELATIONS
Maximum Project Requirements
M/D No. Description Moisture % Density pcf Moisture Density
1 Reddish Brown Clayey Sand w /trace sandstone 14.0 113.0 Optimum +4 95 min
2 Tan crushed limestone w/ Sandy Clay 14.5 115.5 Optimum +4 95 min
FIELD DENSITY TESTS
TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY
NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max)
Retaining wall
1 Sandy Lake Road, Station 43 +75, 50' left 6" 1 16.0 130.5 112.5 100
Retaining wall
2 Sandy Lake Road, Station 42 +75, 50' left 6" 1 15.3 129.8 112.6 100
Retaining wall
3 Sandy Lake Road, Station 47 +75, 45' left 6" 2 14.6 126.2 110.1 95
Test results on this report meet project specification.
/
6 '� '
A Technician: Julio Perez Started: 9:OOam Finished: 12:OOp i ga
Report Distribution: p i
(1) City of Coppell i �
(1) City of Coppell . Scott Watson, AET
(1) Tiseo Paving CMT Operations Manager