Loading...
ST9301-LR060105 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 Engineering 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 :=-i:. . - Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 248092 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 12/29/2005 Coppell TX 75019 Report Date: 01/05/2006 Project: East Sandy Lake Road � ST 93 -01 1 � O Services: Perform In -Place Density Test in accordance with ASTM Standards. C � PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 Moisture Density ASTM D -2922 ASTM D -3017 Gauge Serial No: 36438 Current: 719 Current: 2687 Test Mode: DT Previous: 722 Previous: 2735 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Silty Sand w/ Sandstone & Gravel 11.0 98.0 Optimum +4 98 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pci) (pct) (% max) Wall backfill 1 Sandy Lake Road, 45' left, Station 42 +50, 6" 1 14.5 111.4 97.3 99 elevation 439 Wall backfill 2 Sandy Lake Road, 43' left, Station 43 +50, 6" 1 14.2 111.2 97.4 99 elevation 439 Wall backfill 3 Sandy Lake Road, 41' left, 43 +90, elevation 6" 1 14.9 111.8 97.3 99 439 Test results on this report meet project specification. / Al Technician: Julio Perez Started: 12:15p Finished: 3:15pm E t ti / 'n i ': . % Report Distribution: / (1) City of Coppell 1 � i / ( 1 ) City of Coppell K. Scott Watson, AET (1) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 1 r Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 i./ i 1� 1 V ! 4 2696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 ; Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 248119 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 12/30/2005 Report Date: 01/05/2006 Project: East Sandy Lake Road it ST 93-01 0 z _ n Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Gauge: Troxler 3430 Test Methods: ASTM D -2922 Moisture Density ASTM D -3017 Gauge Serial No: NA Current: 718 Current: 2660 Test Mode: DT Previous: 719 Previous: 2687 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Silty Sand w/ Sandstone & Gravel 11.0 98.0 Optimum +4 98 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pct) (pct) (% max) Wall backfill 1 Sandy Lake Road, 40' left, Station 42 +10, 6" 1 14.8 112.4 97.9 100 elevation 439.5 Wall backfill 2 Sandy Lake Road, 43' left, Station 42 +75, 6" 1 15.0 112.9 98.2 100 elevation 439.5 Wall backfill 3 Sandy Lake Road, 41' left, Station 43 +90, 6" 1 14.2 111.2 97.4 99 elevation 439.5 Wall backfill 4 Sandy Lake Road, 42' left, Station 42 +50, 6" 1 14.4 111.0 97.0 99 elevation 440 Wall backfill 5 Sandy Lake Road, 40' left, Station 43 +00, 6" 1 14.9 110.9 96.5 98 elevation 440 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 2 Report No.: 248119 Project No.: 059909 Client: City of Coppell TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcl) (pcf) (% max) Wall backfill 6 Sandy Lake Road, 39' left, Station 43 +87, 6" 1 14.1 111.0 97.3 99 elevation 440 Wall backfill 7 Sandy Lake Road, 49' left, Station 42 +25, 6" 1 14.7 111.4 97.1 99 elevation 440.5 Wall backfill 8 Sandy Lake Road, 42' left, Station 42 +90, 6" 1 14.9 111.8 97.3 99 elevation 440.5 Wall backfill 9 Sandy Lake Road, 45' left, Station 44 +00, 6" 1 15.0 111.0 96.5 98 elevation 440.5 Test results on this report meet project specification. 4, �e �� o Technician: Julio Perez Started: 6:45am Finished: 12:30p �i Report Distribution: �� �, (1) City of Coppell �f Cr" � t / ( 1 ) City of Coppell K. Scott Watson, AET (I) Tiseo Paving CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 2 of 2