Loading...
ST9301-LR051114 Y` n E ngineering 8908 Ambassador Row, Dallas, TX 75247 it 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 243428 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 10/14/2005 Report Date: 11/14/2005 Project: East Sandy Lake Road p, ST 93-01 I .0 4 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN LD.: 2446H MEASURED SLUMP CONCRETE SUPPLIER: Tiseo PLACEMENT DATE: 10/14/2005 (inches) PLANT: On site WEATHER CONDITIONS: Cloudy 3.0 SPECIFICATION REQUIREMENTS TIME SAMPLED: 8:O2am BATCH TIME: 7:53am STRENGTH: 3600 psi @ 28 Days TEMPERATURE (F) - AIR 68 F CONCRETE: 84 F SLUMP (in): 3 tt - 5 tt TRUCK NO: NA TICKET NO: NA AIR ( %): 4% - 6% AIR CONTENT ( %): 4.6 UNIT WEIGHT (pcf): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 except 9.1.2 Paving, main lane left of centerline, Station 65 +27 to 65 +85 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: Curb at Station 65 +85 ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (Ibs. force) (psi) TYPE 1 1 10/17/2005 3 6.00 28.26 108450 3840 Unbonded Cap 1 2 10/21/2005 7 6.00 28.26 132540 4690 Unbonded Cap 1 3 11/11/2005 28 6.00 28.26 155710 5510 Unbonded Cap 1 4 11/11/2005 28 6.00 28.26 160280 5670 Unbonded Cap Average 5590 1 4 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd 11 SS Page 1 of 2 Aone Engineering 8908 Ambassador Row, Da117.s, TX 75247 2696 Gravel Drive, Fort `Forth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 243376 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 10/14/2005 Report Date: 11/14/2005 Project: East Sandy Lake Road 1 i ST 93 -01 �`� " Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN I.D.: 2446M MEASURED SLUMP CONCRETE SUPPLIER: Tiseo PLACEMENT DATE: 10/14/2005 (inches) PLANT: On site WEATHER CONDITIONS: Clear 2.5 SPECIFICATION REQUIREMENTS TIME SAMPLED: 9:4Oam BATCH TIME: 9:25am STRENGTH: 3600 psi @ 28 Days TEMPERATURE (F) - AIR 71 F CONCRETE: 85 F SLUMP (in): 2" maximum TRUCK NO: NA TICKET NO: NA AIR ( %): 4% - 6% AIR CONTENT ( %): 4.5 UNIT WEIGHT (pct): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 Paving, westbound lane, Station 32 +00 to 26 +36 except 9.1.2 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: Station 31 +50, centerline ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (Ibs. force) (psi) TYPE 1 1 10/17/2005 3 6.00 28.26 107030 3780 Unbonded Cap 1 2 10/21/2005 7 6.00 28.26 117830 4170 Unbonded Cap 1 3 11/11/2005 28 6.00 28.26 151420 5350 Unbonded Cap 1 4 11/11/2005 28 6.00 28.26 145710 5150 Unbonded Cap Average 5250 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. OISS Page 1 of 2 ,, 8908 Ambassador Row, Dallas, TX 75247 , e Engineering 2 696 Gravel Drive, Fort Worth, TX 76118 =tx 6300 Rothway, Ste. 150, Houston, TX 77040 x r.:14,4,T41,4,,;, r x - �; = '', .-4; Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 243376 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 10/14/2005 Coppell TX 75019 Report Date: 11/14/2005 Project: East Sandy Lake Road , A , , , A 9 ( ST 93 -01 at) � Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN I.D.: 2446M MEASURED g p y SLUMP CONCRETE SUPPLIER: Tiseo PLACEMENT DATE: 10/14/2005 (inches) PLANT: On site WEATHER CONDITIONS: Clear 2.0 SPECIFICATION REQUIREMENTS TIME SAMPLED: 12:5 013111 BATCH TIME: 12:48pm STRENGTH: 3600 psi @ 28 Days TEMPERATURE (F) - AIR 79 F CONCRETE: 88 F SLUMP (in): 2" maximum TRUCK NO: NA TICKET NO: NA AIR ( %): 4% - 6% AIR CONTENT ( %): 4.6 UNIT WEIGHT (pct): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 Paving, westbound lane, Station 32 +00 to 26 +36 except 9.1.2 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: Station 27 +00, centerline ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (lbs. force) (psi) TYPE 2 1 10/17/2005 3 6.00 28.26 99640 3520 Unbonded Cap 2 2 10/21/2005 7 6.00 28.26 117560 4160 Unbonded Cap 2 3 11/11/2005 28 6.00 28.26 151680 5360 Unbonded Cap 2 4 11/11/2005 28 6.00 28.26 147110 5200 Unbonded Cap Average 5280 2 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. :MSS Page 2 of 2