Loading...
ST9301-LR050719 8908 Ambassador Row, Dallas, TX 75247 ', 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 r Corporate Phone: (214) 630 - 9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 237742 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 07/14/2005 Coppell TX 75019 Report Date: 07/19/2005 Project: East Sandy Lake Road ST 93 -01 \� 2Z Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Gauge: Troxler 3430 Test Methods: ASTM D -2922 Moisture Density ASTM D -3017 Gauge Serial No: 35519 Current: 661 Current: 2624 Test Mode: DT Previous: 675 Previous: 2612 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Sandy Silty Clay 12.5 116.5 Optimum +5 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max) Roadway 1 East Sandy Lake Road, elevation 447.5, 6" 1 14.9 133.8 116.4 100 Station 27 +00, 3rd lift Roadway 2 East Sandy Lake Road, elevation 447.5, 6" 1 15.2 133.3 115.7 99 Station 30 +00, 3rd lift Test results on this report meet project specification. Ii 7,7 Rone. 1 f ri �. Technician: Julio Perez Started: 12:30p Finished: 4:30pm i A K Report Distribution: L (1) City of Coppell �y Stark (1) City of Coppell Project Manager (1) Tiseo Paving LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be ap d of l except in full without the written approval of Rone Engineering Services, Ltd. ® i 8408 Ambassador Row, Dallas, TN 75247 tone 2696 Gravel Drive, Fort Worth, Tx 76118 6300 Rothway, Ste. 150, Houston, TX 77040 , Corporate Phone: (214) 630 -9745 F IN -PLACE DENSITY TESTING Report No.: 237707 Client: City u Coppell Project No.: 059909 Pro Ms. Suzan Taylor j PO Box 9478 Date of Service: 07/13/2005 Coppell TX 75019 Report Date: 07/19/2005 Project: East Sandy Lake Road �� � ST 93 -01 Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA Standard Counts CONTRACTOR: Tiseo Paving Company Gauge: Troxler 3430 Moisture Density Test Methods: ASTM D -2922 Gauge Serial No: 35519 ASTM D -3017 Current: 675 Current: 2612 Test Mode: DT Previous: 670 Previous: 2578 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Sandy Silty Clay 12.5 116.5 Optimum +5 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max) Roadway 12 9 125.1 110.8 95 1 East Sandy Lake Road, wall, Station 27 +00, 6" 1 1st lift Roadway 12.9 127.2 112.7 97 2 East Sandy Lake Road, wall, Station 29 +50, 6" 1 1st lift Roadway 12.5 125.3 111.4 96 3 East Sandy Lake Road, elevation 463, 6" 1 Station 33 +50, 3rd lift Roadway 4 East Sandy Lake Road, elevation 444.03, 6" 1 12.8 125.6 111.3 Station 36 +00, 3rd lift Test results on this report meet project specification. / - it. R , � : � � g eering Technician: Julio Perez Started: 12:OOp Finished: 3:30pm Report Distribution: _ (1) City of Coppell Clay Stark P (1) City of Coppell Project Manager (1) Tiseo Paving LIMITATIONS. The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced 1 of I except in full without the written approval of Rone Engineering Services, Ltd.