ST9301-LR050617 E ` b 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 235669 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Date of Service: 06/10/2005 Coppell TX 75019 Report Date: 06/17/2005 t Project: East Sandy Lake Road 4' ST 93 - l . \9:0643 I \ Services: Perform In -Place Density Test in accordance with ASTM Standards. \ *, C4 J Lt U` PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 Moisture Density ASTM D - 2922 ASTM D -3017 Gauge Serial No: 35518 Current: 742 Current: 2742 Test Mode: DT Previous: 737 Previous: 2737 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Sandy Silty Clay 12.5 116.5 Optimum +5 95 min 2 Light Brown Sandy Clay w/ Limestone Fragments 11.0 122.5 Optimum +5 95 min FIE_I,D DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max) Fill 1 Westbound lane, Station 56 +00, Elevation 6" 1 15.0 132.3 115.0 99 446.92, centerline left Fill 2 Westbound lane, Station 53 +00, Elevation 6" 1 14.8 128.1 111.6 96 446.33, centerline Fill 3 Westbound lane, Station 50 +00, Elevation 6" 1 14.1 132.2 115.9 99 446.75, centerline right Test results on this report meet project specification. Technician: Joe Jernigan Started: 2:15pm Finished: 3:45pm RoneE - ' •• mg Report Distribution: 4111,41K (1) City of Coppell (1) City of Coppell C 't• (1) Tiseo Paving Proj Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 1 8908 Ambassador Row, Dallas, TX 75247 2 696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 235610 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 06/10/2005 Report Date: 06/17/2005 Project: East Sandy Lake Road ST 93 -01 NO Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: ASTM D - 2922 Gauge: Troxler 3430 Moisture Density ASTM D -3017 Gauge Serial No: 35518 Current: 742 Current: 2742 Test Mode: DT Previous: 736 Previous: 2737 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Sandy Silty Clay 12.5 116.5 Optimum +5 95 min 2 Light Brown Sandy Clay w/ Limestone Fragments 11.0 122.5 Optimum +5 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pct) (pct) (% max) Fill 1 Westbound lane, Station 62 +00, Elevation 6" 1 14.9 129.1 112.4 96 448.80, centerline Fill 2 Westbound lane, Station 59 +00, Elevation 6" 1 16.2 128.9 110.9 95 447.93, centerline right Test results on this report meet project specification. ,� Rone n:'g Technician: Joe Jernigan Started: 9:45am Finished: 12:OOp i Report Distribution: (1) City of Coppell (1) City of Coppell Clay Stark (1) Tiseo Paving Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 1