Loading...
ST9301-LR050613 8908 Ambassador Row, Dallas, TX 75247 2 696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 A:.:, a • . Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell �(/,(�- Report No.: 233668 Ms. Suzan Taylor .��" Project No.: 059909 PO Box 9478 22 Date of Service: 05/12/2005 Coppell TX 75019 �� 7� l Report Date: 06/13/2005 Project: East Sandy Lake Road ST 93 -01 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN LD.: 1703 MEASURED SLUMP CONCRETE SUPPLIER: LMC PLACEMENT DATE: 05/12/2005 (inches) PLANT: 7 WEATHER CONDITIONS: Mostly cloudy 2.75 SPECIFICATION REQUIREMENTS TIME SAMPLED: 3:00pm BATCH TIME: 2:24pm STRENGTH: 3600 psi @ 28 Days TEMPERATURE(F) - AIR 80 F CONCRETE: 86 F SLUMP (in): 3" maximum TRUCK NO: 1042 TICKET NO: 7152593 AIR ( %): 3% - 6% AIR CONTENT ( %): 4.7 UNIT WEIGHT (pcf): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 #3 interior wall for box culvert, Station 42 +75, 25' north except 9.1.2 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: Same as above, 1st lift ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (Ibs. force) (psi) TYPE 1 1 05/17/2005 5 6.00 28.26 95070 3360 Unbonded Cap 1 2 05/19/2005 7 6.00 28.26 104600 3700 Unbonded Cap 1 3 06/09/2005 28 6.00 28.26 135990 4810 Unbonded Cap 1 4 06/09/2005 28 6.00 28.26 131820 4660 Unbonded Cap Average 4740 1 5 Hold LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd 01SS Page 1 of 2 Report No.: 233668 Rone Engineering Project No.: 059909 Project Client: City of Coppell Water added at site: 5 gallons Standby, concrete arrived at 2:45pm Technician: Shawn Deal Started: 1:3Opm Finished: 4:15pm u i r g><n • ering Report Distribution: (1) City of Coppell (1) City of Coppell V Clay Stark (1) Tiseo Paving Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. QISS Page 2 of 2