Loading...
ST9301-LR050421 one Eng E �"! !°6 �1 8908 Ambassador Row, Dallas, TX 75247 f [ i i I 1 f 2696 Gravel Drive, Fort Worth, TX 76118 L 6300 Rothway, Ste. 150, Houston, TX 77040 a_. Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 231494 Ms. Suzan Taylor Project No.: 059909 PO Box 9478 Coppell TX 75019 Date of Service: 04/09/2005 02-C1.(ic Report Date: 04/21/2005 Project: East Sandy Lake Road r- ............... ao* ST 93 -01 4 Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 ASTM D -2922 Moisture Density ASTM D -3017 Gauge Serial No: 35557 Current: 656 Current: 2781 Test Mode: DT Previous: 663 Previous: 2776 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Clayey Sand w /trace sandstone 14.0 113.0 Optimum +4 95 min 2 Brown Sandy Clay w/ limestone fragments & 10.5 122.0 Optimum +4 95 min Organics FIELD DENSITY TESTS TEST PROBE MID MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pcf) (pcf) (% max) Paving subgrade 1 Eastbound Sandy Lake Road, Station 40 +50 6" 1 14.0 123.3 108.2 96 Paving subgrade 2 Eastbound Sandy Lake Road, Station 43 +50 6" 1 15.5 125.1 108.3 96 Test results on this report meet project specification. / Rone O l'�y n Technician: Julio Perez Started: 11:30a Finished: 1:15pm ' Report Distribution: if , (1) City of Coppell (1) City of Coppell Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. )7TM Page 1 of 1 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 * En 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 231427 Ms. Suzan Taylor ^ \�' Project No.: 059909 PO Box 9478 (� V Date of Service: 04/08/2005 Coppell TX 75019 \, Report Date: 04/21/2005 _� Project: East Sandy Lake Road ST 93 -01 110ZZ0 .35 01, Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 ASTM D -2922 Moisture Density ASTM D -3017 Gauge Serial No: 35557 Current: 663 Current: 2776 Test Mode: DT Previous: 663 Previous: 2775 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Brown Sandy Clay w/ limestone fragments & 10.5 122.0 Optimum +4 95 min Organics 2 Reddish Brown Clayey Sand w /trace sandstone 14.0 113.0 Optimum +4 95 min FIELD DENSITY TESTS TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pci) (pci) (% max) Paving subgrade 1 Eastbound Sandy Lake Road, Station 26 +50 6" 1 12.5 130.5 116.0 95 Paving subgrade 2 Eastbound Sandy Lake Road, Station 30 +50 6" 1 10.9 134.4 121.2 99 Paving subgrade 3 Eastbound Sandy Lake Road, Station 32 +75 6" 1 11.0 128.5 15 : 95 Test results on this report meet project specification. I Technician: Julio Perez Started: 9:00am Finished: 11:15 R ; _ erng Report Distribution: (1) City of Coppell _ (1) City of Coppell Clay Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. D7TM Page 1 of 1