Loading...
ST9301-LR061025 Zone Engineering 8908 Ambassador Row, Dallas, TX 75247 Engineering 4221 Freidrich Lane, Ste 195, Austin, TX 78744 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Report No.: 267025 Ms. Suzan Taylor Project No.: 0611391 PO Box 9478 Date of Service: 09/22/2006 Coppell TX 75019 Report Date: 10/25/2006 Project: East Sandy Lake Road ST 93 -01 Completion l v / Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Tiseo Paving Company MIX DESIGN I.D.: 1703 MEASURED D CONCRETE SUPPLIER: LMC PLACEMENT DATE: 09/22/2006 (inches) PLANT: 7 WEATHER CONDITIONS: Partly cloudy 3.0 SPECIFICATION REQUIREMENTS TIME SAMPLED: 4:OOpm BATCH TIME: 3:26pm STRENGTH: 4000 psi @ 28 Days TEMPERATURE (F) - AIR 99 F CONCRETE: 97 F SLUMP (in): 4" maximum TRUCK NO: 1125 TICKET NO: 7171085 AIR ( %): 4% - 6% AIR CONTENT ( %): 4.5 UNIT WEIGHT (pct): NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 Retaining wall over box culvert, eastbound Sandy Lake Road, 1100 block except 9.12 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1231 SAMPLE LOCATION: First 15' from west to east ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH FRACTURE SET NO. TESTED (days) (inches) (sq.in.) (Ibs. force) (psi) TYPE 1 1 09/29/2006 7 6.00 28.26 106120 3750 Unbonded Cap 1 2 10/20/2006 28 5.99 28.17 127920 4540 Unbonded Cap 1 3 10/20/2006 28 5.99 28.17 137210 4870 Unbonded Cap Average 4710 1 4 Hold Water added at site: 10 gallons i4 pt, ' Technician: Daniel Myers Started: 2:15pm Finished: 4:45pm Report Distribution: /'�,� . (1) City of Coppell ( — (1) City of Coppell K. Scott Watson, • T (1) Tiseo Paving Company Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 01SS Page 1 of 1