Loading...
ST9301-LR060220 r s lone 8908 Ambassador Row, Dallas, TX 75247 2 696 Gravel Drive, Fort Worth, TX 76118 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 251043 Ms. Suzan Taylor Project No.: 0611391 PO Box 9478 Date of Service: 02/14/2006 Coppell TX 75019 Report Date: 02/20/2006 Project: East Sandy Lake Road ST 93-01 Completion , Ip . � 8 r . .5 Services: Perform In -Place Density Test in accordance with ASTM Standards. j/j1 S ` , PROJECT DATA CONTRACTOR: Tiseo Paving Company Standard Counts Test Methods: Gauge: Troxler 3430 Moisture Density ASTM D - 2922 ASTM D -3017 Gauge Serial No: 33438 Current: 582 Current: 2563 Test Mode: DT Previous: 581 Previous: 2536 MOISTURE DENSITY RELATIONS Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Reddish Brown Silty Sand w/ Sandstone & Gravel 11.0 98.0 Optimum +4 98 min TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pet) (pct) (% max) Wall backfill 1 Sandy Lake Road, Station 44 +50, elevation 6" 1 13.9 111.3 97.7 100 440.5 Wall backfill 2 Sandy Lake Road, Station 44 +50, elevation 6" 1 14.4 110.2 96.3 98 4441 Wall backfill 3 Sandy Lake Road, Station 44 +50, elevation 6" 1 13.7 110.6 97.3 99 441.5 Wall backfill 4 Sandy Lake Road, Station 44 +50, elevation 6" 1 14.7 110.9 96.7 99 442 Wall backfill 5 Sandy Lake Road, Station 44 +6, elevation 6" 1 14.2 110.3 96.6 99 440.5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 2 Report No.: 251043 EINIMEN W. Project No.: 0611391 Client: City of Coppell TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. ( %) (pci) (pct) (% max) Wall backfill 6 Sandy Lake Road, Station 44 +6, elevation 6" 1 13.2 110.4 97.5 99 441 Test results on this report meet project specification. Technician: Julio Perez Started: 8:OOam Finished: 5:45 pm v /�' Report Distribution: ring! ►/ (1) City of Coppell (1) City of Coppell K. Scott Watson, AET (1) Tiseo Paving Company CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 2 of 2