ST8805-CS 890207Jerry ParcPM Consulting Ertgirleers February 7, 1984 Mr. Russel~Doy~e, P.E. CityEngi~eer City of ~oppell P O Bo~/478 Coppe¥1, Texas 75019 214/471-2251 RI: JP No. 88009; Construction Improvement Plans; Parkway Boulevard and High Szhool Access Road; Coppe11, Texas Dear Russell: Enclosed are three sets of the sanitary sewer, water, storm drainage and paving improvement plans for Parkway Boulevard (West) and the High School Access Road. The plans have been corrected in accordance with final comments received from Ginn, Inc. Final revisions have included: Trench Safety drawings have been added to the Water, Sanitary Sewer and Storm Drainage Plans. 0 Corner clips are shown on the west side of the Parkway BouleVard - Denton Tap Road intersection. The corner clips have been sized in accordance with minimum requirements as directed in our previous discussions and to ensure that the proposed 16-inch ductile iron water main is contained within the easements. A drawing showing these corner clips with dimensions, legal descriptions and a committment letter to dedicate these corner clip easements have been provided to the City. m Proposed 16-inch valves are shown on Sheet Utility Plans. 4 of the Material requirements on the water line encasement pipe under Parkway Boulevard have been added~to the plans. Since our last submittal of the Paving Improvement plans on January 9, 1989, we have added the following information: 1. Proposed fences along the Right-of-Way lines of proposed streets. ~"' 320 Westway Place, Suite 501 · Arlington, Texas 76018 · Metro (817) 467-2418 · (817) 465-0259 Hr. Russell Doyle, P.E. JP No. 88009 February 7, 1989 Page 2 of 2 2. Details for installation of brick pavers. Requirement to seed area 20 feet adjacent to proposed Right-of-Ways as well as non-paved areas within Right- of-Ways. Proposed 16-inch water line crossing Parkway Boulevard west of Denton Tap Road, for reference. We are currently awaiting documentation from the City regarding the revised escrow amount required for the water line to be constructed by the City under Denton Tap Road. Also we understand that ABQ Development Corporation should submit a proposed agreement to the City requesting that the City pay oversize reimbursement for the sixteen inch water line in Parkway Boulevard upon completion of construction in accordance with the Subdivision Ordinance. Please advise me when these plans are approved. Sincerelyy~ try Parche', P.E. JP:ch cc: Mr. Jay Chester, P.E./ABQ Development Corporation Mr. Kevin Peiffer, P.E./Ginn, Inc. Mr. Steve Goram/City of Coppell Mr. Jeff Hawkins/Pierce-Lunsford & Associates Enclosure: 3 Sets of Construction Plans