SW0801-LR110420f1LLIPINCE
GEOTECFif11CML
GRC7UP
Acct I D: 1770
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
File No: C10 -1036
Report Date: 04/20/2011 Previously Reported: 03/30/2011
Project: Sidewalk Improvements
Location: Sidewalk S. bound Denton Tapp, 36' E. x 40' S. from SW corner of
View Point Mortgage
Client: City of Coppell
Date Sampled: 03/22/2011
Sampled By: Lane, William
By Order Of: Larry Davis
Order Number: 1770
Number of
Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 98793
Material: CONCRETE Test Method: See Below
TEST RESULTS Report No: 98793
Page 1 of 1
Quantity Represented: 10 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173,
C1064 and C138. Compressive strenqth tests per ASTM C39.
Orig: City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Maximum
Compressive Average
Spec Age Tested Diameter
Area
Load Cure
Strength
Strength
Nbr (date : days)
(in)
(in')
(lbs) Break Type Loc
(PSI)
(PSI) Comments
A 03/29/11:
7 4.00
12.57
54,565 Type 5 Lab
4,340
4,340
B 04/19/11:
28 4.00
12.57
63,325 Type 3 Lab
5,040
C 04/19/11:
28 4.00
12.57
65,170 Type 3 Lab
5,190
5,110
D
HOLD (see remarks) -
�j
l
PE
El
Type 1
Type 2 Type 3 Type 4
Type 5
Type 6
Specification:
3,000 psi @ 28 days
Date Received:
03/23/2011
Slump: 4.5 Inches
Transported By: Redi -Mix
Curing Method:
Standard
Air Content: 3.5%
Source /Sampled At: Truck / Center
Time Sampled:
9:00 am
Plant: P259
Temp.: Ambient:
60 °F Mix: 63 °F
Mix Code: 10J11504
Truck/Ticket No: 1377 / 25307214
Quantity Represented: 10 cu. yds.
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173,
C1064 and C138. Compressive strenqth tests per ASTM C39.
Orig: City of Coppell (Coppell, TX) Attn: Mr. Larry Davis (1 -cc copy)
Respectfully Submitted,
Alliance Geotechnical Group
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.