Loading...
MA1006-CS110601 (7/8/2011) George Marshall - Re: Video DetectionPage 1 From: Per Birdsall To: johnny@melselectric.com CC: George Marshall, adrian@bowmanconstruction.com Date: 6/1/2011 4:41 PM Subject: Re: Video Detection That is what I just recently checked with the Engineer on. It's good. Thanks, Per -----Original Message----- From: Johnny Heine <johnny@melselectric.com> Cc: Adrian Bowman <adrian@bowmanconstruction.com> To: Per Birdsall <PBIRDSALL@coppelltx.gov> Sent: 6/1/2011 3:16:57 PM Subject: RE: Video Detection We have schedule Paradigm for next Monday at 9:00 am to switch over to the temp signals. Is this date and time ok? From: Per Birdsall [mailto:pbirdsall@coppelltx.gov] Sent: Thursday, May 26, 2011 3:58 PM To: Johnny Heine Cc: Brent Adams; Larry Morton Subject: Video Detection We have two cameras and the associated components (borrowing one component from Southwestern). I'll need to check further if all the hardware is present for mounting. We also have several old Opticom heads that I believe are operational which can be verified next week. We should still have some span wire mounts for the Opticom. More information next week on the minor hardware issues. Thanks, Per (7/8/2011) George Marshall - Re: Video & LoopsPage 1 From: Per Birdsall To: khiggins@paradigmtraffic.com CC: George Marshall, Brent Adams, Cody Wildoner Date: 6/1/2011 4:35 PM Subject: Re: Video & Loops Thanks. That is the way I thought it should work. I heard from Mel's about Monday. You should prime your tech that this is what will need to be done. All the video equipment will be there and the initial programming of the Naztec controller with the new phase sequence will be ready. I'll have a tech there too if anything else is needed. Thanks again. Per -----Original Message----- From: "Keith Higgins" <KHiggins@paradigmtraffic.com> To: Per Birdsall <PBIRDSALL@coppelltx.gov> Sent: 6/1/2011 4:08:29 PM Subject: RE: Video & Loops Not a problem Per, There are 16 logic ground/true inputs on the front of the tap. They are pins 1 -16 The outputs of the loops can be run from the detector panel into the input pins. Then in the detector file the inputs can be tied with logic to the TS2 output pins and the inputs can be passed through the sdlc bus to the controller... is that what you have in mind. By the way, Johnny with Mel's scheduled for one of my guys to be at this Monday... Thanks, Keith Higgins Field Service Manager Paradigm Traffic Systems 817-247-6023 ________________________________ From: Per Birdsall [mailto:pbirdsall@coppelltx.gov] Sent: Wednesday, June 01, 2011 12:52 PM To: Keith Higgins Subject: Video & Loops (7/8/2011) George Marshall - Re: Video & LoopsPage 2 Hate to keep asking but I'll have a situation come Monday if not. According to literature there are 16 TS1 inputs on the front of the TAP. If I understood it, the pins would be 16 thru 32. The output from the detector rack would need to be routed to one of these inputs? I need a little more step by step. Has this been done anywhere else? Thanks, Per Per Birdsall, Traffic Control / Streets Operations Manager City of Coppell 816 S. Coppell Rd. P.O. Box 9478 Coppell, Texas 75019 972-462-5150 972-462-5199 fax pbirdsall@coppelltx.gov