ST0701-CS091211 (8/31/2011) Keith Marvin - RE: HDPE alternativePage 1 From: Keith Marvin To:Oyen, Matt; Rodriguez, Jorge CC:Harris, Kody; Littleton, Dave Date: 12/11/2009 5:18 PM Subject: RE: HDPE alternative I'm not sure I understand the need for a temporary solution to this. There is nothing draining through here now. Is this delaying a critical path item? I'm concerned that if we place this pipe in here we may be making it more difficult for AT&T to resolve the conflict. I don't have enough information to support this proposal at this time. I'd be happy to discuss this in detail on Monday. Keith Keith Marvin, P.E. Project Engineer (972) 304-3681 >>> "Matt Oyen" <MattO@PacTrust.com> 12/11/2009 11:38 AM >>> This solution of utilizing HDPE pipe with a concrete collar at the transition is acceptable to PacTrust. However, we would obviously defer to the City for approval of the temporary alternate native for piping over the existing AT&T duct bank. Thanks, Matthew Oyen, PE Construction Manager Pacific Realty Associates, L.P. (PacTrust) 15350 SW Sequoia Pkwy, Suite 300 Portland, OR 97224 Office: 503 624-6300 Cell: 503 523-7619 matto@pactrust.com ________________________________ From: Rodriguez, Jorge [mailto:jrodriguez@halff.com] Sent: Friday, December 11, 2009 9:23 AM To: Matt Oyen; Keith Marvin Cc: Harris, Kody; Littleton, Dave Subject: HDPE alternative Hi guys I attach a temporary alternative using HDPE pipe at AT&T crossing location. Also, as the flow line at the existing Box Junction Box is a little higher than shown on the plans, I had to raise the flow line of Lat B-5 wye inlet as shown. The sketch shows the adjusted flow lines from Sta. 0+00.0 to Lat B-5. If this alternative is acceptable, please disregard the previous ones I sent. Please call Dave Littleton at 214-346-6213 or me if any question (8/31/2011) Keith Marvin - RE: HDPE alternativePage 2 thanks Jorge Rodriguez, P.E. Project Manager HALFF ASSOCIATES, INC. 1201 N. Bowser Road Richardson, Texas 75081 Phone 214-346-6203 Fax 214-739-0095 www.halff.com Page 1 of 1 Keith Marvin - HDPE alternative From:   "Rodriguez, Jorge" <jrodriguez@halff.com> To:   Matt Oyen <MattO@PacTrust.com>, Keith Marvin <kmarvin@ci.coppell.tx.us> Date:   12/11/2009 11:28 AM Subject:   HDPE alternative CC:   "Harris, Kody" <kharris@lhlacy.com>, "Littleton, Dave" <dlittleton@halff.com> Attachments:   20091211HDPE.pdf   Hi guys   I attach a temporary alternative using HDPE pipe at AT&T crossing location. Also, as the flow line at the existing Box Junction Box is a little higher than shown on the plans, I had to raise the flow line of Lat B-5 wye inlet as shown. The sketch shows the adjusted flow lines from Sta. 0+00.0 to Lat B-5. If this alternative is acceptable, please disregard the previous ones I sent. Please call Dave Littleton at 214-346-6213 or me if any question     thanks   Jorge Rodriguez, P.E. Project Manager   HALFF ASSOCIATES, INC.   1201 N. Bowser Road Richardson, Texas 75081 Phone 214-346-6203 Fax 214-739-0095 www.halff.com   file://C:\Documents and Settings\radloo\Local Settings\Temp\XPgrpwise\4B222CE9City_...8/31/2011