ST0701-ES091216(8/31)2011) Keith Marvin - Re: water easement Page - 1 ] From: Keith Marvin To: Rodriguez, Jorge CC: Littleton, Dave; matto @pactrust.com Date: 12/16/2009 4:02 PM Subject: Re: water easement Attachments: 20091216(PROP.WATERESMT).pdf; Utility.doc Jorge, I suggest we make this a "Utility Easement" and that we limit it to the area I have highlighted. I see no reason to overlay an existing UE with a new one. I also don't think we need to expand the footprint of the existing easements in the area. I'm also attaching our standard language for easement dedication. This is essentially the same language that is applied to the plat when easements are dedicated by plat. Halff will need to prepare the exhibits to go along with this dedication instrument. The area in question is currently a Drainage Easement, and we would just overlay the necessary area with a Utility Easement to contain the proposed water line location. Feel free to call me with any questions. Keith Keith Marvin, P.E. Project Engineer (972) 304 -3681 >>> "Rodriguez, Jorge" < jrodriguezCa@halff.com > 12/16/2009 2:17 PM >>> Keith The attached sketch shows the proposed 15 ft water easement layout. Could you please check and let me know if it is acceptable. I would also like from you to send me the front language that the City want to use for said easement. Could you also let me know about the approval of the updated sanitary sewer (Sheet C5.04r) Thanks Jorge Rodriguez, P.E. Project Manager [cid :125580420@ 16122009 -323A] HALFF ASSOCIATES, INC. 1201 N. Bowser Road Richardson, Texas 75081 Phone 214- 346 -6203 Fax 214- 739 -0095 1AAA/rnt halff rnm . o �I Jll -- STA 19 +37.2 LINE A CL PAV. STA 35 +41.1(25' RT.) INSTALL: EXISTING TREE LO ATIONS MD BUSHES / 1 -12" 45° BEND t ° TO BE FIELD VERIFI D. ADJUST WATER ' ° I ALIGNMENT TO AV ID CONFLICT WITH TREES. CONTRA F, s ° `', ll I, r! BUSH REMOVAL. CT R TO MI IMIZE s w t ' t STA 20 +09.6 LINE A= 1 JCL PAV STA. 35 +95.7 (67.95' RT.) � EONNECT TO EXISTING / j� i i _ - i Y - ; 6" WATER MAIN 19 ` \ 1 STALL: 1 12 "x6" TAPPING SLEEVE AND VALVE, f! \ Cfoe AMT 1 F 16 "= 507.30 +l- 0 C - J (P R PLANS) (FIELD VERIFY) -� - J Bp uo CAUTION!!! 4� 1` 1 P A V E R -' PROPOSED 12" WATER AND MENT - - - PROPOSED 24" STORM DRAIN 20' vYil -tTY E/G` . 3264) CROSSING. (VOA- 9 0218, PG l FL 24" RCP = 507.30 o i } � r STA 19 +76.2 LINE A - J BEGIN CONCRETE N I ENCASEMENT S --- CAUTION!!! PROPOSED 12" WATER AND PROPOSED UNDERGROUND. 1 1 ELECTRIC CROSSING CAUTION!!! I ELEC. EL= 509.00 PROPOSED 12 WATER AND EXISTING 72" STORM DRAIN CROSSING. EX. 72 "RCP FL =504.00 +/ I 32 (PER PLANS) STA 19 +96.2 LINE A I 1 1 l END CONCRETE t ` ENCASEMENT +, I `? } Goa TE G° ' 20� 9R A t US AGE G t off y 1 SASS ftrc a STA 19 +98.0 LINE A= CL PAV STA 35 +84.0 (67.95' RT) t 1 i INSTALL: 1 -12" 45° BEND } t,