Loading...
ST0701-CS100106Pagel of 3 Keith Marvin - RE: Waste water stub outs From: "Matt Oyen" <MattOgPacTrust.com> To: "Farris, Miranda" <mharris @lhlacy.com >, "Farris, Kody" <kharris @lhlacy.com >, "Rodriguez, Jorge" <jrodriguezghalff.com> Date: 1/6/2010 12:57 PM Subject: RE: Waste water stub outs CC: <kmarvin @ci.coppell.tx.us >, "Littleton, Dave" <dlittleton @halff.com >, "Murawski, Ron" <rmurawskiglhlacy.com >, "Richard Odell" <RODELLgci.coppell.tx.us> Kody - per our conversation please proceed with this work effort on a time and materials basis. Once we have the existing conditions information we will work with Halff to develop plans for the desired crossing locations for the City's approval. If you have any questions, or need any additional information please contact me. Thanks, Matthew Oyen, PE Construction Manager Pacific Realty Associates, L.P. (PacTrust) 15350 SW Sequoia Pkwy, Suite 300 Portland, OR 97224 Office: 503 624 -6300 Cell: 503 523 -7619 matto @pactrust.com From: Harris, Miranda [mailto: mharris @lhlacy.com] Sent: Tuesday, December 22, 2009 1:58 PM To: Harris, Kody; Rodriguez, Jorge Cc: kmarvin @ci.coppell.tx.us; Matt Oyen; Littleton, Dave; Murawski, Ron Subject: RE: Waste water stub outs reviewin � After th original attached • • ; the cost of proposed i be $ Thi inclu potholing and surveying the 3 locations i drawing Pl ease i • Miranda Harris LH LACY COM 1880 Crown Rd. Dallas TX 75234 file: / /C: \Documents and Settings \radloo \Local Settings\ Temp \XPgrpwise \4B4488BACity_... 8/31/2011 Page 2 of 3 Office: 214- 357 -0146 Fax: 214- 350 -0662 From: Harris, Kody Sent: Monday, December 21, 2009 10:46 AM To: Rodriguez, Jorge Cc: kmarvin @ci.coppell.tx.us; matto @pactrust.com; Littleton, Dave; Murawski, Ron; Harris, Miranda Subject: RE: Waste water stub outs We are evaluating the cost impact to obtain the information requested. As soon as I have that information I will send an estimate for your review. Thanks, KODYHARRIS PROJECT MA NA CER LM TA CY COMPANY From: Rodriguez, Jorge [mailto:jrodriguez @halff.com] Sent: Monday, December 21, 2009 10:40 AM To: Harris, Kody Cc: kmarvin @ci.coppell.tx.us; matto @pactrust.com; Littleton, Dave Subject: RE: Waste water stub outs !i J When do y ou think we will receive the below re information. I'll be out next week, so please let me know for further coordination. Thanks From: Rodriguez, Jorge Sent: Wednesday, December 16, 2009 3:34 PM To: 'kharris @lhlacy.com' Cc: 'kmarvin @ci.coppell.tx.us'; 'matto @pactrust.com'; Littleton, Dave Subject: Waste water stub outs Kody We were checking possible waste water stub outs locations and we are pretty tied at the existing 24" water crossing locations. The attached sketch shows three possible stub out locations, but we need to verify the top elevations of the existing 24 " water main at the clouded locations. We are giving approximate coordinate values at these locations. We are trying to connect the stub outs to the proposed manholes. Please provide this information as soon as you can to move forward on this issue. Thanks very much file: / /C: \Documents and Settings \radloo \Local Settings\ Temp \XPgrpwise \4B4488BACity_... 8/31/2011 Page 3 of 3 Jorge Rodriguez, P.E. MEN Project Manager IBUE HALFF HALFF ASSOCIATES, INC. 1201 N. Bowser Road Richardson, Texas 75081 Phone 214 - 346 -6203 Fax 214 - 739 -0095 www.halff.com Privileged /Confidential Information may be contained in this message. If you are not the addressee indicated in this message, have received this message in error (or responsible for delivery of the message to such person), you may not copy or deliver this message to anyone. In such case, you should destroy this message and kindly notify the sender by reply email. Please advise immediately if you or your employer do not consent to Internet email for messages of this kind. Opinions, conclusions and other information in this message that do not relate to the official business of our firm shall be understood as neither given nor endorsed by it. file: / /C: \Documents and Settings \radloo \Local Settings\ Temp \XPgrpwise \4B4488BACity_... 8/31/2011 Page 1 of 1 Keith Marvin - Waste water Stub outs From: "Rodriguez, Jorge" <jrodriguezghalff.com> To: Matt Oyen <Matt0gPacTrust.com >, "Farris, Kody" <kharrisglhlacy.com> Date: 1/6/2010 11:15 AM Subject: Waste water Stub outs CC: Keith Marvin <kmarvingci.coppell.tx.us >, "Littleton, Dave" <dlittletonghalff.com> Attachments: ww stubouts.pdf; tceq requirements.pdf Hi guys The attached sketches shows all the crossing locations for stub out # 3 and # 1 . I strongly recommend both stub outs to serve all the area for the property to the south. The most acceptable is alternative # 3 and we expect that the top elevation should be 502.90 or lower as shown per plans. Alternative # 1 is pretty tie but is a good location for an stub out to serve the property to the south. I also request to verify the flow line for the sanitary sewer manholes at both locations. I also attach the TCEQ for crossing requirements. We must follow these requirements for any of these crossings. Please call me for any question thanks Jorge Rodriguez, P.E. MEN Project Manager 1BUE HALFF HALFF ASSOCIATES, INC. 1201 N. Bowser Road Richardson, Texas 75081 Phone 214 - 346 -6203 Fax 214 - 739 -0095 www.halff.com file: / /C: \Documents and Settings \radloo \Local Settings\ Temp \XPgrpwise \4B4470BBCity_... 8/31/2011 OE IVI H 5 _ 5+00 t a X t �Yl dl lQ. a q-0 RO n �J f •2 "� t -- I— 1 3 --------------------- ------ - - - - -- i Il 6� _ y 3 +44 1 1, G �QC n 9� yy a 0� � 12."w � op h t. 3 2 �� tia off J J J r r JJ r J r (boo P� r �J , J r / r l J � op h t. 3 2 �� tia off J J J r r JJ r J r (boo P� Texas Administrative Code Page 2 of 7 (1) The technical specifications for joints for gravity pipe must include the materials and methods used in making joints. (2) Materials used for gravity pipe joints must prevent infiltration and root entrance. A joint must: (A) include rubber gaskets; (B) include polyvinyl chloride (PVC) compression joints; (C) include high density polyethylene compression joints (D) be welded; (E) be heat fused; or (F) include other types of factory -made joints. (3) The technical specifications must include ASTM, AWWA, ANSI, or other appropriate national reference standards for the joints. (d) Separation distances between public water supply pipes and wastewater collection system pipes or manholes. (1) Collection system pipes must be installed in trenches separate from public water supply trenches. (2) Collection system pipes must be no closer than nine feet in any direction to a public water supply line. (3) If a nine -foot separation distance cannot be achieved, the following guidelines will apply. (A) If a collection system parallels a public water supply pipe the following requirements apply. (i) A collection system pipe must be constructed of cast iron, ductile iron, or PVC meeting ASTM specifications with at least a 150 pounds per square inch (psi) pressure rating for both the pipe and joints. (ii) A vertical separation must be at least two feet between the outside diameters of the pipes. (iii) A horizontal separation must be at least four feet between outside diameters of the pipes. (iv) A collection system pipe must be below a public water supply pipe. (B) If a collection system pipe crosses a public water supply pipe, the following requirements apply: (i) If a collection system is constructed of iron, ductile iron or PVC with a minimum pressure rating of 150 psi, the following requirements apply: (I) A minimum separation distance is six inehs between outside diameters of the pipes. http: / /info.sos. state. tx. usl plslpub lreadtac$ext.TacPage ?sl =R &app =9 &p_dir = &p rloc= &p_tl... 1/6/2010 Texas Administrative Code Page 3 of 7 (II) A collection system pipe must be below dpublic water supply pipe. (III) Collection system pipe joints must be located as far as possible from an intersection with a public water supply line. (ii) If a collection system pipe ciczss�es under a,publ�c �vater'supply pipe and the collection system pipe is constructed of acrylonitrile butadiene styrene (ABS) truss pipe, similar semi -rigid plastic composite pipe, clay pipe, or concrete pipe with gasketed joints, the following requirements apply: (I) A minimum separation distance is two feet. (II) If a collection system pipe is within nine feet of a public water supply pipe, the initial backfill around the collection system pipe must be: ( -a -) sand stabilized with two or more 80 pound bags of cement per cubic yard of sand for any section of collection system pipe within nine feet of a public water supply pipe. ( -b -) installed from one quarter of the diameter of the collection system pipe below the centerline of the collection system pipe to one pipe diameter (but not less than 12 inches) above the top of the collection system pipe. (iii) If a collection system crosses over a puble tivater sipply:ppe, one of the following procedures must be followed: (1) Each portion of a collection system pipe within nine feet of a public water supply pipe must be constructed of cast iron, ductile iron, or PVC pipe with at least a 150 psi pressure rating using appropriate adapters. (II) A collection system pipe must be encased in a joint of at least 150 psi pressure class pipe that is: ( -a -) centered on the crossing; (b -) sealed at both ends with cement grout or manufactured seal; ( -c -) at least 18 feet long; ( -d -) at least two nominal sizes larger than the wastewater collection pipe; and ( -e -) supported by spacers between the collection system pipe and the encasing pipe at a maximum of five -foot intervals. (4) Public water supply pipe and collection system manhole separation. (A) Unless collection system manholes and the connecting collection system pipe are watertight, as supported by leakage tests showing no leakage, they must be installed a minimum of nine feet of horizontal clearance from an existing or proposed public water supply pipe. (B) If a nine -foot separation distance cannot be achieved, the requirements in paragraph (3) of this http: / /info.sos. state. tx. usi pls 1publreadtac$ext.TacPage ?sl =R &app= 9 &p_dir = &p rloc= &p_tl... 1/6/2010