ST0701-SP100421L. H. LACY COMPANY, Ltd.
P.O. Box 541297
Dallas, TX 75354-1297
Ph: (214)357-0146
Submittal
Job: 5262
Spec Section No:
SWern Blvd (SCoppell-Beltline) Submittal No: 29
DCM 11A; Blk E Revision No: 0
Coppell, TX Sent Date: 4/21/2010
Spec Section Title:
Submittal Title: Paint Submittal for proposed Southwestern Blvd. Bridge
Contractor:
L. H. LACY COMPANY, Ltd,
Halff Associates
Jorge Rodriquez
Architect's Stamp
I Engineer's Stamp I
DATE
DATE
JOB NO, e
ATTENTION
VVE ARE SENDING YOU OAttached O Under separate cove
O Shop drawings OPhnts O Plan plee
O Copy ofletter O Change order
O
the following items
S pecifications
COPIES
DATE
NO.
DESCRIPTION
THESE ARE TRANSMITTED oo checked below:
&�
�\For approval O Approved as submitted O RouubmUL____copioofon approva
O For your use O Approved aanoted OGubmit___cupieafor distribution
• As requested O Returned for corrections O Return-corrected prints
• For review and comment O
O FOR BIDS DUE 19O PRINTS RETURNED AFTER LOAN TOU8
REMARKS
COPYTO
SIGNED: -
If enclosures are not as noted. kindiv not1tv us at once.
ILI , MY
167, S1 i
in k 7*9
L F I
A
t
I I I'D', aa_
NIP101, ZMA-11,A] M AFF RK7 �M'W_M
PRODUCT INFORMATION
PRODUCT DESCRIPTION
RECOMMENDED USES
SWD BRIDGE AND HIGHWAY WATERBASED CONCRETE
For use over prepared:
Concrete and masonry surfaces
HVY STAIN is a 100% acrylic emulsion stain specifically en-
Poured or precast concrete
gineered for exterior, above-grade, masonry Surfaces requir-
Concrete masonry block
ing high performance protection , and outstanding color re-
tention. It develops excellent early moisture resistance.
Chemical Resistant
Examples:
Concrete barriers
Fast dry
Bridges
Slope paving
PRODUCT CHARACTERISTICS
PERFORMANCE CHARACTERISTICS
Finish: Flat
System Tested: (unless otherwise indicated)
Substrate: Concrete
Color: White, and a wide range
Surface Preparation: Clean, dry, sound
of colors available
Finish: 2 ets. Bridge and Highway Waterbased Concrete Hvy
Stain
Volume Solids: 31%+-2%
Weight Solids: 48%+-2%
VOC (EPA Method 24): Unreduced: 149 g/I
Weight per Gallon: 10.9 lb
Coverage Per Coat:
Recommended: 225 -350 sq ft/gal approximate
Texclot Method:
2 coats SWID Bridge and Highway Waterbased Hvy Stain
@ 150 sq ft/gal min.
Drying Schedule @ 77*F, 50% RH:
temperature and humidity dependent
To touch: 1 hour
To recoat: 4 hours
Shelf Life: 36 months, unopened, at 77 °F
Flash Point: 201 degrees f, PMCC
Reducer/Clean Up: Water
Southwestern Division June 2002
�I
PRODUC INFORMATION
RECOMMENDED SYSTEMS
SURFACE PREPARATION
Concrete /Masonry, smooth surface:
2 cts. SWD Bridge and Highway Waterbased Concrete Stain
@ 225 to 350 sq ft per gallon per coat.
Surface must be clean, dry, and in sound condition. Remove
all oil, dust, grease, dirt, form release , curing agent, and other
Texdot Method:
foreign material to ensure adequate adhesion.
2 cts SWD Bridge and Highway Waterbased Concrete Stain
@ 150 sq ft/gal min.
Refer to product Application Bullitin for detailed surface prepa-
ration information.
For Anti- Graffiti Protection
1 ct. SWD Bridge and Highway Waterbased Concrete Hvy
Concrete and Masonry: Cured, clean, dry, sound , allow to
Stain @ 150 sq. ft./ gal
cure for at least 28 days.
1 ct. Invisi- Shield B65CJ Series Clear
@2.0to3.0 mils dft..
COLOR 4Av
Tint: Use Blend -A -Color
Directions For Graffiti Removal
For extended color retention use Envirotoner
Maximum of 8 oz. per gal.
Use PLASTI- MASTER, as manufactured by
GRAFFITI MASTER or equivilent.
SW qt. #426 -7902 gal #458 -2441.
Color: Wide range of colors possible
Spray effected area until saturated.
Allow time for solvent action to begin.
APPLICATION CONDITIONS
Scrub with stiff bristle brush until graffiti is in suspension.
It may be necessary to re -apply remover.
FOLLOW DIRECTIONS ON LABEL.
Temperature: 40 °F minimum, 110 °F maximum
(air, surface, and material)
At least 5 °F above dew point
Relative humidity: 85% maximum
Refer to product Application Bulletin for detailed application
information.
ORDERING INFORMATION
Packaging 5 and 55 gallon containers
Weight per gallon: 10.9 lb (may vary by color)
SAFETY PRECAUTIONS
Refer to the MSDS sheet before use.
Published technical data and instructions are subject to change
The systems listed above are representative of the product's
use. Other systems may be appropriate.
without notice. Contact your Sherwin- Williams representative
for additional technical data and instructions.
APPLICATION BULLETIN
SURFACE PREPARATION
APPLICATION CONDITIONS
Surface must be clean, dry, and in sound condition. Remove
Temperature: 40 ° F minimum, 110 ° F maximum
all oil, dust, grease, dirt, and other foreign material
(air, surface, and material)
to ensure adequate adhesion.
At least 5 ° F above dew point
Relative humidity: 85% maximum
Concrete and Masonry
Surfaces should be thoroughly clean and dry. Concrete and
mortor must be cured at least 28 days@ 75 degrees F.
Remove all loose mortar and foreign material. Surface must
APPLICATION EQUIPMENT
be free of laitance, concrete dust, dirt, form release agents,
moisture curing membranes, loose cement and hardners.
The following is a guide. Changes in pressures and tip sizes
Poured Concrete New
may be needed for proper spray characteristics. Always purge
Surface must be clean, dry, sound, and offer sufficient profile
spray equipment before use with listed reducer. Any reduction
to achieve adequate adhesion. Minimum Substrate cure is 28
Must be compatible with the existing environmental and appli-
days at 75 degrees F. Remove all form release agents, curing
cation conditions.
compounds, salts, efflorescence, laitance, and other foreign
matter by Suitable means. Allow to dry thoroughly prior to
Reducer/Clean Up:......... Water
coating-
Airless Spray
Old
Pressure ....................... 2000 psi
Surface preparation is done in much the same manner as new
Hose ............................. 1/4" ID
concrete; however, if the concrete is contaminated with oils,
Tip .. ............................... .015" - .019"
grease, chemicals, etc., they must be removed by cleaning
Reduction ............. Not recommended
with a strong detergent. Refer to ASTM D 4258. Form release
agents, hardeners, etc. must be removed by sandblasting,
Brush
shotblasting, mechanical scarification, or waterblasting at
Brush ............................ Natural Bristle
a minimum of 3000 Psi and 3 gallon per minute flow rate, or
Reduction .... ...... --- ... Not recommended
other suitable means. If surface deterioration presents an
unacceptable rough surface, use an approved compound or
Roller
filler to patch and resurface damaged concrete.
Cover ............................ 3/8"-3/4" nap synthetic cover.
Allow to dry thoroughly prior to coating.
Reduction ..................... Not recommended
If specific application equipment is listed above, equivalent
equipment may be substituted.
Always follow the ASTM methods listed below:
ASTM D4258 Standard Practice for Cleaning Concrete.
Southwestern Division June 2002
1107ur=
A
17
F!
MV We 'A' 101112W I
APPLICATION BULLETIN
APPLICATION PROCEDURES
PERFORMANCE Tips
Surface preparation must be completed as indicated.
When using spray application, use a 50% overlap with each
Do not apply to a damp surface.
pass of the gun to avoid holidays, bare areas, and pinholes.
Do not apply over heavy chalk.
If necessary, cross spray at a right angle.
Do not apply if the surface temperature is
During the early stages of drying, the stain is sensitive to rain,
below 40F., when rain is expected within
dew, high humidity, and moisture condensation. If possible,
3 hours, or when the relative humidity is above
plan painting schedules to avoid these influences during the
85%.
first 16-24 hours of curing.
Mixing Instructions: Mix stain thoroughly by boxing and
Spreading rates are calculated on volume solids and do not
stiring before use.
include an application loss factor due to surface profile, rough-
ness of porosity of the surface, skill and technique of the ap-
Apply stain at the recommended film thickness and spreading
plicator, method of application, various surface irregularities,
rate as indicated below:
material lost during mixing, spillage, overthinning, climatic
conditions, and excessive film build.
Recommended Spreading Rate per coat*
Coverage: 225 to 350 sq ft /gal approximate
Excessive reduction of material can affect film build, appear-
ance, and adhesion.
Texclot Method:
2 cts SWID Bridge and Highway Waterbased Hvy Stain
Refer to Product Information sheet for additional performance
@ 150 sq ft/gal min.
characteristics and properties.
Drying Schedule @ 77*F, and 50% RH:
To touch: I hour
To recoat: 4 hours
Drying time is temperature, humidity, and film thickness
dependent.
Application of stain above maximum or below minimum rec-
ommended spreading rate may adversely affect coating per-
formance.
CLEAN UP INSTRUCTIONS
SAFETY PRECAUTIONS
Clean spills and spatters immediately with soap and warm
Refer to the MSDS sheet before use.
water. Clean tools immediately after use with soap and warm
water.
Published technical data and instructions are subject to change
without notice. Contact your Sherwin-Williams representative