Loading...
ST0701-LR100212CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 193.0067 Irerracon Service Date: 01/14/10 8901 Carpenter Frwy. Report Date: 02/12/10 Revision 3 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Attn: Keith Marvin PO Box 9478 Coppell, TX 75019 Southwestern Boulevard Coppell Road to Grapevine Creels Coppell, TX Project Number: 94091193 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Sample Date: 01/14/10 Sample Time: 0955 Sampled By: Christopher P. Moran Mix ID: DCS01 -1504 Weather Conditions: Overcast, light breeze Supplier: Redi -Mix Accumulative Yards: 10 Batch Size (cy): 10 Batch Time: 0916 Plant: 136 Placement Method: Pump Truck No.: 1 192 Ticket No.: 25154810 Water Added Before (gal): 15 Water Added After (gal): 0 Field Test Data Sample Location: Sta. 13 +85 Test Result Specification Placement Location: Bridge Deck, east Bound, Sta. 13 +56 to Slump (in): 5 3 -5 Sta. 14 +05 Air Content 6.0 3 -6 Concrete Temp. (F): 57 Ambient Temp. (F): 50 Plastic Unit Wt. (pct): 146.1 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 01115110 01 /18/10 4 110,400 3,910 4 1 2 6.00 28.27 01115110 01/21/10 7 136,420 4,830 2 1 3 6.00 28.27 01115110 01/28/10 14 168,690 5,970 5 1 4 6.00 28.27 01115110 02/11/10 28 176,550 6,240 2 1 5 6.00 28.27 01115110 02/11/10 28 178,230 6,300 2 Average (28 days) 6,270 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and cast gompressive strength samples. Terracon Rep.: Christopher P. Moran Started: 0900 Reported To: Finished: 1430 Contractor: Lacy Construction Report Distribution: (1) City of Coppell l'X (1) City of Coppell TX Reviewed By: (1) City of Coppell 'I'x (2) Halff Assoc hic Eric J. Cleveland, P.E. (1) Lacy Construction (1) PacTrusl Pacific Really Associates LP Senior Project Manager Test Methods: ASTM C 31, ASTM 09, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ('1(0001. 5a1-09, Rev- -, Page I of 1