ST0701-LR100601CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091 194.0101 Irerrac Service Date: 05/20/10 8901 Carpenter Frwy. Report Date: 06 /01 /10 Dallas, TX 75247 214- 630 -1010 Reg No:F -3272 Client Project PacTPtISt Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creels to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1250 Plant: 07 Truck No.: 7060 Ticket No.: 7217116 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 3 -5 4.5 3 -6 96 84 145.2 Laboratory Test Data Set Specimen Diameter Area Date No. ID (in) (sq in) Received 1 1 6.00 28.27 05/21/10 1 2 6.00 28.27 05/21/10 1 3 6.00 28.27 05/21/10 1 4 6.00 28.27 05/21/10 Sample Information Test Load Sample Date: 05/20/10 Sample Time: 1338 Sampled By: Juan Lopez Weather Conditions: Cloudy Accumulative Yards: 6.5 Batch Size (cy): 6.5 Placement Method: Direct Discharge Water Added Before (gal):5 Water Added After (gal): 0 Sample Location: Sta. 11 +00 Placement Location: Inlet Approach on Southwestern Boulevard at Sta. 4 +43 and Sta. 11 +00 Age at Maximum Date Test Load Tested (days) (Ibs) 05/27/10 7 100,470 06/03/10 14 06/17/10 28 06/17/10 28 Compressive Strength Fracture (psi) Type 3,550 4 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations perform required field tests and samples. Terracon Rep.: Juan Lopez Started: 1330 Reported To: Contractor: Lacy Construction Finished: 1500 ive Report Distribution: Reviewed By: (1) PacTrust Pacific Really Associates LP (1) City of Coppell TX - � Halff Assoc Inc Sri eveland, P.E. (1) City of Coppell 'rX (-) Senior (1) Lacy Construction oject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of l Cuuaoi..i- zs -nt, Re" -1