Loading...
ST0701-LR100615CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 94091194.0096 Irerracon Service Date: 05/17/10 8901 Carpenter Frwy. Report Date: 06/15/10 Revision 2 - 28 -day results Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Southwestern Boulevard Attn: Matthew Oyen Grapevine Creels to Beltline Road 15350 Southwest Sequoia Pkwy Ste 300 Coppell, TX Portland, OR 97224 Project Number: 94091194 Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1341 Plant: 07 Truck No.: 5024 Ticket No.: 7217039 Field Test Data Test Slump (in): Air Content (o /t): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Result Specification 4 3 -5 4.0 3 -6 90 88 142.2 Laboratory Test Data Sample Date: 05/17/10 Sample Time: 1400 Sampled By: Jesus Rojas Weather Conditions: Cloudy Accumulative Yards: 6.5 Batch Size (cy): 6.5 Placement Method: Direct Discharge Water Added Before (gal):10 Tested Water Added After (gal): 0 Sample Location: See Placement Location Placement Location: Manhole Tops, Sta. 28 +75 and Sta. 05/24/10 27 +24 Age at Maximum Set Specimen Diameter Area Date Date Test Load No. ID (in) (sq in) Received Tested (days) (lbs) 1 1 6.00 28.27 05/18/10 05/24/10 7 108,850 1 2 6.00 28.27 05/18/10 05/31/10 14 120,050 1 3 6.00 28.27 05/18/10 06/14/10 28 135,060 1 4 6.00 28.27 05/18/10 06/14/10 28 136,240 Average (28 days) Compressive Strength Fracture (psi) Type 3,850 2 4,250 2 4,780 2 4,820 2 4,800 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive stre gth samples. Terracon Rep.: Jesus Rojas Started: 1300 Reported To: Finished: 1530 Contractor: Lacy Construction Report Distribution: Reviewed By: (1) PacTnist Pacific Realty Associates LP (1) City of Coppell TX (I) City of Coppell TX (2) HaItTAssoc Inc ric J. Clevel nd, P.E. Senior Project Manager (1) Lacy Constniction Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 4- 28-10, Rev.4 Pagel of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT �` Report Number: 94091 194.0110 Service Date: 06/07/10 8901 Carpenter Frwy. Report Date: 06/15/10 Dallas, TX 75247 214- 630 -1010 Reg No: F -3272 Client Project PacTrust Pacific Realty Associates LP Attn: Matthew Oyen 15350 Southwest Sequoia Pkwy Ste 300 Portland, OR 97224 Southwestern Boulevard Grapevine Creek to Beltline Road Coppell, TX Project Number: 94091194 Material Information Sample Information Specified Strength: 3,000 psi @ 28 days Mix ID: 1261 Supplier: Lattimore Batch Time: 0925 Plant: 3 Truck No.: 5016 Ticket No.: 3277433 Field Test Data Test Slump (in): Air Content Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pef): Result Specification 5 1/2 3 -5 4.0 3 -6 91 86 144.5 Sample Date: 06/07/10 Sample Time: 1035 Sampled By: Francisco J. Morillo Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal):20 Date Water Added After (gal): 0 Sample Location: Howell Drive and Southwestern Blvd. Placement Location: Sidewalk at E corner of Howell Drive (sq in) and Southwestern Blvd. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (Ibs) (psi) Type 1 1 6.00 28.27 06/08/10 06/14/10 7 78,960 2,790 5 1 2 6.00 28.27 06/08/10 06/21/10 14 1 3 6.00 28.27 06/08/10 07/05/10 28 1 4 6.00 28.27 06/08/10 07/05/10 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and c st c in •e ive strength samples. Terracon Rep.: Francisco J. Morillo Started: 0930 Reported To: Superintendent Finished: 1200 Contractor: Lacy Construction Report Distribution: (1) PacTrust Pacific Realty Associates LP (1) City of Coppell TX Reviewed B (1) City of Coppell TX (2) I-Ialff Assoc Inc Eric J Cleveland, P.E. (1) Lacy Constriction Senior roject Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. ('110001.4 -2s -tit, RevA Page I of I