Lesley Retail Addn-CS110927 Pacheco Koch DALLAS • FORT WORTH • HOUSTON September 27, 2011 PK No.: 2768 -1 1.082 Mr. Michael Garza CITY OF COPPELL 255 Parkway Boulevard Coppell, Texas 75019 Re: DIVIDEND DRIVE Lesley Retail Addition Coppell, Texas Dear Mr. Garza: This letter is to notify you that the enclosed Construction Plans have been revised in accordance with your August 12, 2011, Review Memorandum and red lined plans. The following items have been addressed as per the referenced review: GENERAL COMMENTS (CITY COMMENTS LETTER) • Coordinate with the Billingsley property and Quick Trip property, these plans do not match with their proposed developments (sanitary sewer, drainage areas, drainage design, and water). Response: Plans have been coordinated. • Provide an overall preliminary utility plan. How does this coordinate with the rest of the development? Response: Provided separately • Our details now call out for #4 bars on 18 -inch centers. Response: Changed in paving notes. • The detention pond property needs to be platted. Response: Per Gary Seib, provide landscape plan at this time, detention area will be dedicated by separate instrument. PAVING PLAN AND PROFILE COMMENTS (CITY COMMENTS LETTER) • Provide access to the pedestrian button at the intersection. Response: Ramp and sidewalk added to plans. 8350 N CENTRAL EXPY • STE 1000 • DALLAS, TX 75206 -1 61 2 • (972) 235 -3031 ■ F (972) 235 -9544 • WWW.PKCE.COM Mr. Michael Garza September 27, 2011 Page 2 GRADING PLAN COMMENTS (CITY COMMENTS LETTER) • The side slopes of the detention pond should be 4:1. Response: Addressed • Provide a copy of the permission from the owner to the north to grade and discharge onto their property. Response: Will provide letter under separate cover. We have received a draft and are currently coordinating language. WATER PLAN AND PROFILE COMMENTS (CITY COMMENTS LETTER) • The development on both sides of Dividend Drive should have looped water line systems and allow for additional taps. One connection to the water line is not adequate for service. Response: Per your meeting with Jack Evans, Pacheco Koch, it was agreed that water can be looped in the future with development of the remainder of the property. • The water line shall be constructed by boring. Response: Addressed. • Show all utility crossing on the profile, including the 60 -inch storm line. Response: Addressed. • Will there be a need for irrigation taps in the median? Response: Propose no sodding of median. STORM SEWER PLAN AND PROFILE COMMENTS (CITY COMMENTS LETTER) • Provide capacity calculations for the storm sewer lines. Response: Calculations added to plans, Refer to sht. C3.4 SANITARY SEWER PLAN AND PROFILE COMMENTS (CITY COMMENTS LETTER) • How will the future development to the east of Quick Trip be serviced? Response: 325 ft ± of 8' sanitary sewer line extended east along north QT property line to pick up site to the east. • Get a copy of Billingsley's proposed project, there will be a signaled intersection where you propose to tie into the existing sanitary sewer system. Response: Tie in location has been moved to the north to tie into the next downstream manhole on the existing 12" sanitary sewer. We have coordinated with Billingsley's engineer. Proposed intersection is now shown on the plans. Mr. Michael Garza September 27, 2011 Page 3 • Belt Line Road plans show an existing stub out where you are proposing to tie into the sanitary sewer. Response: See preceding response. GENERAL COMMENTS (CITY RED LINES) • Use proposed drainage area delineations for the QT property. Response: QT Drainage areas incorporated into plans. • Use City of Coppell Standard Construction details for Erosion Control. Response: Pacheco Koch Standard Details removed on Sht. C5.1 and City of Coppell Standard details referenced. STORM SEWER PLAN AND PROFILE COMMENTS (CITY RED LINES) • Revise pond outfall structure to the one Type "B" headwall. Response: Outfall redesigned. WATER PLAN AND PROFILE COMMENTS (CITY RED LINES) • Clearance between storm lateral ('STM- 4' @STM -5) and water line "W -3 ". Response: Water line "W -3" adjusted to meet minimum clearance. • Discrepancy between connection types pointed out (16" x 12" TEE vs 16" x 12" TAP). Response: Conflicting call outs have been revised. If you have any questions or need any additional information, please call at your earliest convenience. Sincerely, J• ' . London, P.E. JCL /dtn 2768 -297 Pacheco , Koch L)ALLAS ■ FORT WORT ■ HOUSTON September 28, 2011 PK No.: 2768 - 11.082 Mr. Michael Garza EIT CITY OF COPPELL 255 Parkway Boulevard Coppell, Texas 75019 Re: DIVIDEND DRIVE Coppell, Texas Dear Mr. Garza: Transmitted herewith, via courier service delivery, please find enclosed the following items for your approval: No. Date Description 2 09/28/11 Sets of Civil Plans 1 09/28/11 Comments Response Letter 1 09/28/11 Set of City Red Lines 1 09/28/11 Preliminary Utility Plan If the enclosures are not as noted above, please contact this office immediately. If you have any questions regarding the enclosed items or need any additional information, please call me at your convenience. Sincerely, 411 Mll i jIIIIIIA -- ----, ,_ .y C. London, P.E. JCL /dtn 2768 -298 enc. cc: Todd Jones - Lone Star Realty Advisors -cam- 2 2 3 5 4 t, p ° L( 8350 N CENTRAL EXPY • STE 1000 • DALLAS, TX 75206 -1612 • (972) 235 -3031 • F (972) 235 -9544 • WWW.PK