Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
WA9601-SP 981020
LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shirnek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE ATTACHED ITEMS: Copies Spec Section Submittal No. 6 Various 9 Electrical LETTER OF TRANSMITTAL Date 10/20/98 I Job. No. Arm: Re: 9802 Mr. Gary C. Hendricks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q0198-03 City of Coppell, Texas Description THESE ARE BEING TRANSMITTED: Information for Record O&M Data X Information for Engineer's Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contrect documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS / REMARKS: Signed Joe Swinnea WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 ELECTRICAL ENGINEER SHIMEK, JACOBS & FINKLEA 8333 DOUGLAS AVENUE, #820 DALLAS, TEXAS 75225 [] NO EXCEPTIONS TAKE~EF"~/~KE CORRECTIONS NOTED [] REJECTED I:::] REVISE AND RESUBMI'[ [] SUBMIT SPECIFIED ITEM Corrections or comments made On the Shop araw~ngs dur- ing this rewew do not relieve contractor (rom comphance w~th requtrements ot the drawings and speC~hcataons. This check is only for rewew of general conlormance w~th the design Concept of the prolect and general comphance with the ~nlormation given m the c~.>ntract documents. The ELECTRICAL CONTRACTO :~contractor ~s responsible for conhrmu~g and correlating ,all quantities and ~mens~ens: se(ect~ng fabr~c~hon proc- HARRELL & ASSOCIATES, IN~sses and techniques O1 constr~c~on, coordinating 3007 WOODSIDE DRIVE work with that ot ~li other traoes, and performing his ARLINGTON, TE~S 76016 work ~n a sate and sat,sl~ctory manner (817) 496~661 McCREARY & ASSOCIATES, INC. ~ CONSULTING E GENERAL CONTRACTOR LANDMARK STRUCTURES, INC. 1665 HARMON ROAD FORT WORTH, TEXAS 76177 T T '~ T' WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 SPEC SECTIONS: SC-8 PART 11; SC-20; AND SHEET 12 OF 17 FIXTURES INDEX TYPE a B B1 C D E f G G H h H h MANUFACTURER GENERAL ELECTRIC GENERAL ELECTRIC GENERAL ELECTRIC CROUSE HINDS CROUSE HINDS PRESCOLITE GENERAL ELECTRIC GENERAL ELECTRIC GREENLEE SPAULDING SPAULDING SPAULDING SPAULDING CATALOG NUMBER V2FW17M 1 A1PWADBF W4L40M3A1SN4DBFQ W4L17M3A1SN4DBF VXHBF22GP 43961-116-GR EDP2-ETD TR1 R17MIA1LSS3DBU ARTA183S5.0ADBA POLE CBLH IDRFLBRZCZ / CH70MH 120BRZ AT1 -M400-22-DB-SP2 30-SQST507-T-DB 2/AT 1 -M400-22-DB-S P2 30-SQSTS07-T-DB/215-B2-DB AREA LIGHTING 'ERSAFLOOD' II WALLIGHTER APPLICATIONS - High level wall mounted security and workslighting, tunnel and underpass lighting. Anywhere maximum optical performance is needed. SPECIFICATION FEATURES · UL1572 Listed SUITABLE FOR WET LOCATIONS · CSA Certified · Standard construction is IP55 · Heavy-duty (NEMA) die-cast aluminum housing · Protected inside and out wiffi an electrocoat paint finish · Formed reflector with ALGLAS* finish · Sealed and activated-charcoal filtered optical assembly · Rat, stippled, heat and shock resistant tempered glass or prismatic square borosilicate refractor · Corrosion resistant hardware · Photoelectric receptacle available · Mogul base socket-E39 standard · Surface mountedthrough back with 0.75 inch (19am) threaded ~,.,--~onduit .75 inch (19mm) threaded conduit openings - top and sides for through wiring ORDERING NUMBER LOGIC GE Lighting Systems, Inc. ~ I~LISTEDI V2FW 1 A I P W A DB ~ [ T 1 T -r T F T T LIGHT PRODUCT ID. WATtAGE SOURCE VOLTAGE BALLAST TYPE PE FUNCTION ~ 2401277 e I o b le ta c le included~ w~ connected Grounded same voyage 3 =240 Socket Shell as un~ 4=277 H =HPF Reactor except as 5 =~0 or Lag noted. Order PE Con~ol -. D=~7 K =Hot Resta~ sepa~a~ly. T=~0 L =Super Low 50Hz ~ss A~oreg 6 =~0 M =Mag-Reg Y=240 P =CWI w~ Grounded Socket Shell Cl°XX 07= 70 od II 10=100 Wallighter 15= 150 25=250 40=400 'NOTE Use square Refractor (P) for , 400 watt OPTICAL CONFIGURATION X X X I I I See Ballast and Photometric Selection Table COLOR OPTIONS ~(B=Dark B=Time Delay ('~ Bronze ) Automatically (Stan- ' arl:z ar ) (S;~n-~ GR=Gray P =Prewired with 6 ft (1.8 meters) #14/3 Q=Non-Time Delay .Automatically Switched Quartz A=Socket Position ry Self ~~ The catalog numbers, options and modifications (~on this page are UL Listed unless otherwise noted. I) Registered Trademark of General Electric Company Data aubJect to change without notice I I e) .:. ,_WALLIGHTER 400 LUMINAIRE APPLICATIONS Underpasses, loading docks, building perimeter security and other applications where a high wattage wall mounted luminaire is needed. Also may be mounted horizontally with refractor facing upward for signs and building facades. SPECIFICATION FEATURES -- · UL1572 Listed SUITABLE FOR WET LOCATIONS · UL Listed to meet Canadian National Standards and Codes · Standard construction is IP55 · Sealed and charcoal filtered housing · Die-cast aluminum housing protected inside and out with dark bronze electrocoat paint finish · ALGLAS· finish on aluminum reflector · Heat and impact resistant prismatic glass refractor · Pre-wired terminal board and integral direct-mounted ballast · 3/4-inch NPT conduit entrances sides and top · Photoelectric receptacle available · Optional 1.25-inch (32ram) slipfitter pipe mounting · Mogul base socket .:,~1_,~ Magnapack packaging available - See Technical Section ORDERING NUMBER LOGIC LIGHT PRODUCT ID. ~hter 400 I LISTEDI A I SN4 DB ; CL T T 'F'I'T T IES DISTRIBUTION WATtAGE SOURCE VOLTAGE BALLAST TYPE PE FUNCTION TYPE COLOR OPTIONS XX X X X X X X X XX XXX 15:150 S = 0=12,0/208/See Ballast and See Ballast and '~B=Time Delay (55V} 240/277 Photometric ~eptacle Photometric ~ Bronz~ Automatically 17= 175 ~ Multivolt don Table NOTE' · Selection T le -_-- .S~ched u 20=200 Standard' 1 =120 Receptacle con- ~=Fusing (Not 2,5- Lamp not' 2= ~ nected same ~ ~ available with 5=480 K =Hot Restart control s~pa- ' N NPF Reac or D=347 M=Mag-Reg rately. or Lag 1-1/4 in. [32mm] pipe mounted) The catalog numbers, options end modifications (~on this page are UL Listed unless othenNise noted, Data subject to change without notice Page 220 J'2~, 1997 r _,WALLIGHTER 400 LUMINAIRE APPLICATIONS Underpasses, loading docks, building perimeter security and other applications where a high wattage wall mounted luminaire is needed. Also may be mounted horizontally with refractor facing upward for signs and building facades. SPECIFICATION FEA~'URES' ~ · UL1572 Listed SUITABLE FOB WET LOCATIONS · UL Listed to meet Canadian National Standards and Codes · Standard construction is IP55 · Sealed and charcoal filtered housing · Die-cast aluminum housing protected inside and out with dark bronze electrocoat paint finish · ALGLAS® finish on aluminum reflector · Heat and impact resistant prismatic glass refractor · Pre-wired terminal board and integral direct-mounted ballast · 3/4-inch NPT conduit entrances sides and top · Photoelectric receptacle available · Optional 1.25-inch (32am} slipfitter pipe moundn_c/ · Mogul base socket /;),Z Magnapack packaging available - See Technical Section !s]~t~Jq;ii~L4~LIJ'kH:Jq;IKsZq[; W4L lm A LIGHT PRODUCT ID, WATFAGE SOURCE VOLTAGE BALLAST TYPE GE Lighting Systems NEW PRODUCT L,,,~,--Z,z-,.,I""'7 II - .~]~i1!]i1,1i~tl]I I DB F"' '1" PE FUNCTION "F'I'T I T IES DISTRIBUTION TYPE COLOR OPTIONS W4~ghter 400 XX X X X X X X X XXX ~ Mul~olt ' hie NOTE - S cdon Table 5=~0 K =Hot Resta~ only. Order PE Q=Non-~me Delay con~ol sepa- Automa~cally D=~7 M=Mag-Reg rarely. Swhched Quam N =NPF Reactor or Lag - S =SlipFar (internal 1-1/4 in. [3~m] pipe mounted) The catalog numbers, optlone and modifications (~)on this page are UL Listed unless othenNiae noted, Data subject to change without notice VAPORGARDTM Incandescent Lighting Fixtures Enclosed and Gasketed (Vaportight) Class I, Division 2' Accessories Pg. 1L-6 Parts Pg. 1L-7 Photometric Data Pgs. 1L-8 to 10 Dimensions Pg. 1L-11 1L-5 Crouse-Hinds® VXHB Wall and Box Mounting Max. Lamp Body Only Globe Guard Body with Globe/ Size Cat. # Cat. # Cat. # Guard Cat. # 150 Watt VXHB 15 G53 P50 VXHB 15GP A-21 200 Watt VXHB 12 G23 P21 VXHB12GP Ao23, A-25, PS25 300 Watt VXHB13 G251' P22 VXHB13GP PS-30 Body with Globe/Guard & Reflector Cat. # Dome VXHB15GPRD 30' Angle VXHB15GPRA VXHB12GPRA VXHB13GPRA VXHBF Wall and Junction Box Max, Hub Lamp Body Only Globe Guard Body with Globe/ Size Size Cat. # Cat. # Cat. # Guard Cat. # '/2 150 Watt -. VXHBF15 G53 P50 VXHBF15GP -7, A-21 VXHBF25 G53 P50 VXHBF25GP ~ 200 Watt VXHBF12 G23 P21 ~ 3/, A-23, A-25, PS25 VXHBF22 G23 P21 1/2 300 Watt VXHBF13 G251' P22 % PS-30 VXHBF23 G251 * P22 VXHBF23GP Body with Globe/Guard & Reflector Cat. # Dome VXHBF15GPRD VXHBF25GPRD 30' Angle VXHBF15GPRA VXHBF25GPRA VXHBF12GPRA VXHBF22GPRA VXHBF13GPRA VXHBF23GPRA VXHF Ceiling and Junction Box Max, Hub Lamp Body Only Globe Guard Size Size Cat. # Cat. # Cat. # ~/2 150 Watt VXHF15 G53 P50 % A-21 VXHF25 G53 P50 '/2 200 Watt VXHF12 G23 P21 3/4 A-23, A-25, PS25 VXHF22 G23 P21 ~/2 300 Watt VXHF13 G251' P22 % PS-30 VXHF23 G251 ° P22 Body with Globe/Guard Cat. # VXHF15GP VXHF25GP VXHF12GP VXHF22GP VXHF13GP VXHF23GP ? Body with Globe/Guard & Reflector Cat. # Dome VXHF15GPRD VXHF25GPRD VXHF12GPRD VXHF22GPRD VXHF13GPRD VXHF23GPRD. 30' Angle VXHF15GPRA VXHF25GPRA VXHF12GPRA VXHF22GPRA VXHF13GPRA VXHF23GPRA (Note: To obtain fixture without guard, omit suffix "P" from Cat. No.) Globe G33 is sul)plied with 300W series when guard is not re(luired. See Pg. 1L-3. Copyright® 1992 Cooper Industries, Inc. January 1992 VAW F; ' 'Obstruction Light Compliances: US Military Specification MIL-L-7830 USAF ANA Standards FCC Rules and Regulations Canadian Standards Association (CSA) CROUSE-HINDS AIRPORT LIGHTING PRODUCTS VAW Applications The VAW red obstruction light is used for nighttime obstruction marking of tall structures that may present hazards to air navigation. The VAW is usually steady burning, but may also be flashing if used with an external fiasher unit. Features · Complies with MILSPEC MIL-L-7830 · CSA Certified · Red Fresnel Glass Globes for 360° visibility ...:,--' Threaded Bottom Hub (1 Inch) for mounting · Cast Aluminum Housing with natural finish · Threaded Globes · Accepts traffic signal lamps with USA medium screw base and European E27 base · Operates on 120 or 220-240 volts and 60 or 50Hz frequency power supply when used with proper voltage lamp · Temperature test data are available for the design'and specification of hazardous area applications · Optional Wire Guards (-GG option) · For 6.6A applications, see OAL page CT-11.1 or Option S311 · Lamp Life 8000 hours Dimensions: Inches (Millimeters) 43961 Shipping Weight: 16.0 Ibs. 1.4 kg. .. "' lhipping Volume: 1.4 cu.ft. ,,::~ .04 cu.m. .rrJ 4 ,.,i, ,o~o T 1 Ordering Information I//--31{I I/I-D-I Fixture Type: 43958 = Single 43961 = Double 43950A = Double** /I/ r,l-lc;l l Globe Color: No Symbol Means Red Globe(s) B = Blue C = Clear Y = Yellow G = Green Lamp Type: No Symbols Means Lamp(s) Not Included 116 = 116W 120V 10047-1577 100 = 100W 230V 10047-2145 Options: GG = Wire Globe Guard(s) GR = Ground Wire(s) S311 = Constant Current (6.6A) Lamp(s). No L-823 plug(s). Includes brackets for Joslyn brand lowering device. Crouse-Hinds also offers the complete Joslyn Obstruction Light Lowering System. Request VAW-43950A data sheet OP-1.10 from Parts Guide NAV-016. 43958 8.0 Ibs. 0.7 kg. 0.7 cu.ft. .02 cu.m. 43961 43958 15.00 5.75 (381) 13,38 (340 ..rl, Application FAA Advisory Circular 70/7460-1H "Obstruction Marking and Note: Lighting," Chapter 13, paragraph 134.a advises that steady burning red lights should conform to FAA AC 150/5345-43 or Military Specification MIL-L-7830. TYPE: · 11%' · 83/t4· NEMA GRADE 15W, 30W, 50W Emergency Lighting Unit 13z/s' ~J Lg,J I< 6~/s' ~[ Sealed and gasketed, the NEMA sedes is designed to be strong, rugged and technologically reliable. Made of high impact, engineering grade Valox~polymer, the NEMA series is designed for harsh or corrosive environments where oil. water and dust-tight construction is required. L Standard Features · Complies with NEMA 4X and NEMA 12 ratings · Maintenance-free, lead calcium battery o Dual voltage - 120/277V · .Automatic low voltage disconnect · InJec~on molded high Impact Valoxe housing · Sealed and gasketed. construction · ~ compatible (refer to EL-18) · Thermally compan~ " ~ Regulated charge voltage : · Reverse polarity pmtecti0n · Filtered charger output. · Standard pro-drilled mounting 'flanges · Top conduit entry provided - o PAR-36 sealed beam lamps standard · Halogen lamp standard On ~12 volt units · Full 3 year warranty · % .Brownout protection ·: · Sealed and gasketed test switch and indicator light · AC lockout · CSA LIsted (see other side) o UL924Usted*.-:-,: ..... · .... -,~..,..*,, ,,..,,:! i 'n T Complete Unit )i~EDP2 (6V, 15VV) n EDP7 (6V, 50VV) EDP3 (6V, 30W) n EDP12 (1L~/, D EDP4 (12V, 50W) I::1 EDP15 (12V, 125W} O~T,~TD ' Time delay I::1 EWG1 Wireguard Q NB Nlcad battery~ I:! CVS Continuous Verification System 12 HTR -Heater (spedfy voltage) E3 3 Third head mounted on unit Example: EDP4-ETD . Optional Lamps To order two non-standard lamps with fixture, suffix · catalog number. See EL-11 for details. ; .Example: EDPT-EDHH0608 ': Wireguard and remote heads must be ordered as - separate line item. ". "' "": ' :l: CV$ not trailable wtffi nlcad bs~tePI. PrescditeEmergency · .., .,~-. ;:;:.- ,. :.'.~../..:.-: :.,'EL-13 AREA LIGHTiN'ij ........ >_SALEM" L UMINAIRE APPLICATIONS ..... :' : Residential areas, walkways, shopping centers, malls. SPECIFICATION FEATURES · UL1572 Listed SUITABLE FOR WET LOCATIONS and CSA Certified when polycarbonate refractor is used and 'U' option is chosen - Standard construction is IP54 · Cutoff optics available - TRCR · Die-cast aluminum housing · Hinged canopy · Acrylic Or polycarbonate resin refractors · Integral ballast · Mogul base socket (TRI C vertical; TR1R and TRCR horizontal- 15°) · Stainless steel latch to secure canopy · Terminal Board standard · Plug-in ignitor · No-tool photoelectric (PE) receptacle GE Lighting Systems I q h-I ORDERING NUMBER LOGIC - PRODUCT ID. XXXX See Ballast and Photometric Selection Table TRIC = Salem Luminaire with Roadway LIGHT WATTAGE SOURCE VOLTAGE XX X X 05 = 50 S~ ~ 07 = 70 10 = 100 3 =240 15=150 Standard: 4=277 Lamp not 5 =480 included 7 =120X240 8 =240V Ballast 120V PE Recep- tacle. Not recon- nectable D=347 F = 120X:347 NOTE Dual voltage · connected for lower voltage · Optics NOTE:UL Usted and CSA Certi- fied when PolyCarbon- ate i'efractor is used. See "U" optiota TRCR = Salem Luminaire with Cutoff .,,._ Optics OTE: Use ,20V only on HPF or N F Reactor with Grounded unit except as Socket Shell noted. Order H =HPF Reactor PE Control or Lag separately. M=Mag-Reg N =NPF Reactor or Lag IES DISTRI- BALLAST TYPE PE FUNCTION REFRACTOR BUTION TYPE COLOR OPTIONS X X X X X X XX XXX See Ballast and ~e A = Acrylic I I I BL =Black F =Fusing (Not Photomeffic p- G= Clear Rat See Ballast (Stan- available tacle Glass (TRCR and d with dual NOTE: Recep.~ Photome~c DB =Daj~ ,.:.,,,.0_...,, :,-, voltage as ~ {Available with poly- carbonate v only. Not available with TRCR) 5 =Type V m Trademark ~f. General Electric Compae~y Date .subject to change. 'without notice .. Page 240 January 1997 f I POLES & BRACKETS ALUMINUM AREA LIGHTING POLES Lighting Systems A RT'A Ig "% G s, o/% bB A I 0 TO 2~ FEET (3 TO ~ METERS ) APPLICATIONS SUGGESTED LUMINAIRES P16M, P17M TR1 C, TR1R T10C SPECIFICATION FEATURES · Round tapered. aluminum shaft · Satin grodnd finish - Shaft lengths from 10 to 20 feet · Three inch OD top for mounting single luminaire · Black and dark bronze finishes available · Choice of anchor, transformer, or embedded base · Paint finish is powder coat INFORMATION ONLY A R T "1' -"T' 'T ': Figure 3 '-- '. Transformer · ORDERING NUMBER LOGIC SEE SEU:CTION TABLE FOR ACTUAL ORDERING NUMBERS A ~S 3S ~oA PRODUCT ID. POLE NOMINAL (LUMINAiRE CROSS SHAFT POLE MOUNTING USAGE) SECTION SHAPE MATERIAL HEIGHT (FT) ~ X. XX ~14=14 Base /N~lb~ A SHAFT DIMENSIONS BOTI'0M WALL SHAFT THICKNESS BASE MOUNTING 0D (IN.) (IN.} RNISH TYPE ~~ f;:r~o°," .-~~"~-.,.~ · .= - DB = D:~nkt bronze ~ lumi,~nair~e ~ (:g. 2) (Standard) T =Transformer NOTE: If black or (Fig 3) i dark bronze finish NOTE: is required, Substitute A, E, substitute BL oE or T for X in DB for SN in ordering number ordering number listed in Pole listed in Pole Selection Table. Selection Table. .... CBL Order Specifications TO ORDER FIXTURE: Select appropriate choice from each column as in example below. EXAMPLE: CBL HID FCB BRZ FZ T Series ~Hf~D~~lype Optics (See previous page) FCB - Flood/E- l 7/Medium Base -i~M~tbo~E-17 Medium Base RZ49/Med~um Base 70. ~00. 175 MV 100. 175 PAR38AD - Ad-Med~urn Base MV I 00 PAR38 - Medium Base MH 70. 100 iNC PAR38 - Medium Base Halogen 't5.90. 150. 250 Finish Lens/Shield Accessories CZ - Convex/Full BLK - Black FZ - Flat/Full FH - FladHalf Tree Mount J-Box (Aluminum) INL - Internal Non-Derectional Louver SCl - Sp~ke JoBox w/6' Cordset (Iron) For use with INC lamps only - Spike J-Box (iron) J47AH1 - See J-Boxes (page 63) EXAMPLE: · HID fixtures require a ballast. TO ORDER BALLAST; Select.appropriate choice from each column as in example below. Ballasts require a fixture for a comptete unit. AG 175 MV 120 BRZ Ballast¢ Wattage Lamp Voltage Finish Options ~G ADc',e G"ace CH Co~pos:e Ba.'ec Box ,,, :^ F,: _: ,-;e ,', th ,D:!~"t On:, I C: C3~'Dos.:e B~' ec Box .', 1' F 2: _: ~MP NOT INCLUDED WITH F[XTbRE 5:3. 7C S3.: 50. 175 MH ' 2.O BRZ Bronze 'R T;mper Resstan: Fastene.'s _:3. ':' ~O ;75 HV Z~T'' BLK B',ac, ¢CH & CF e~c os~.,'es o^1;1 O.-ce.'TRKe. seDa,'atei:, Q,,.. .:.~..:z ~Z '.00. SO kiPS ': Ke. ORDER SEPARATELY See pages 59-61 for lamp or'tiering mformat~on. ' ' Consult Greenlee representaz .e fo-' .o!:3~es other than ~ 20. T Remote baZlasts with ,gnators ~a..e ^'~ted star't,n.~ d,stances. See page 62 for further mfo,'mat,on. Loc,d ~'terpretatlons of Nat~ona, :,ect" c Coee ma. ~ary. Consult ';,our local .nspector pr,or to specify,rig voltage other t~'an 120 Photometrics Metal Halide 150W FCB / /MH 2MH 0 4MH3MH2MH IMH O IMH 2MH3MH 4MH With Half Shield NH = Mounhng He,ght High Pressure Sodium 100W FCB 4MH 3MH 21~H IMH 0 I MH 2HIH 31'IH 4MH With Half Shield Setback Setback Correction Factor 5' 1.000 8' ,39~ a0' 250 ~2' Lamp Type Lamp Type Correction Factor 175W Met.v H,fice I 037 150W Met.t Hai~ce 1.000 100W MeLt ~.i,~!,ce ~30 70W Met.!. ~ ~ ice 4 [ 5 I 0()V~ ~'le,~ ..'. '~ !22' 2~_r' Setback 8' ~0' 2' Setback Correction Factor 1.000 .391 250 17q Lamp Type 15OWHPS IOOWI4PS 7OVVIIPS Lamp Type Correction Factor 1684 IOOO Greenlee Lighting Inc. I 15 ATI .ANTA I APPLICATIONS Building facade. recreational areas, accent lighting, small parking areas, swimming pools, tennis courls, and security lighting. CONSTRUCTION FEATURES Optical Housing -- One-piece heavy-duty cast alu- minum with fianged hood to portect the regressed lens. Built-in cast cradles provide rigid alignment of reflectors. Incorporates side door for access into lamp compartment. Lens Assembly -- Extruded aluminum frame, clear, fiat, tempered glass lens and high temperature gasket seal lamp compartment from moisture, dust and insects. Optics -- Reflector is two-piece, alum;cure, symmet- rical half sections, with anodized finish. Identical reflector halves. combinations of specular, semi- diffused and diffused finishes, are utilized to provide up to six beam spread patterns. Ballast Housing -- The heavy duty cast aluminum housing provides excellent heat dissipation and maintenance ease. A rear cast aluminum housing cover, secured by (4) captive stainless steel screws, fully exposes all electircal components for servicing. A weatherproof and thermally controlled cable strain relief connector allows use of 75'C rated cords. All luminaires are equipped with 3' length #14 AWG/3 conductor type SOW-A prewired cords. Index and 'Mounting -- All units are equipped with a vertical degree calibrated quadrant plate and reposi- tioning device. A single index nut seats quadrant plate and provides a positive repositioning stop, returning luminaire to original aiming angle. A %" thick steel trunnion (yoke) bracket is secured by two pivot locking screws. Optional crossarm mounting fitting with horizontal degree scale or a 2" pipe slipfitter assembly is available. Integral Ballast -- Starting rated to -20'F ballast. Metal Halide ballast is constant wattage autotrans- former (CWA) type. High Pressure Sodium ballasts are constant wattage autotransformer type using an electronic starter circuit. Lampholder -- Enclosed mogul porcelain socket with spring loaded, nickel plated center contact and reinforced lamp grip screw shell. High Pressure Sodium sockets are pulse rated. Lamps -- Accommodates all wattages up to and including 400 watt Metal Halide and High Pressure Sodium lamps. Finish- Durable baked-on polyester paint finish is available in 10 standard colors. For other finishes, consult factory. Note: Designed for below horizontal aiming only. Consult factory for upward aiming. Cast Aluminum Housing Cast Aluminum Ballast Box End Cover Effective Projected Area: 2.1 Sq. Ft. Integral Ballast · 15.25 - 17 Sq. SPAULDING SQST - tenon J,,tg' Allowable EPA Nom. Wind Velocity . ht Ordering wrl .3 gust Shaft SizeAnchor Wt./ '~. Number 70 80 90 100 Dim Ga BoltSize Lbs. 10-SQST-411 32 24 18.5 14.5 4 11 ~,x15 91 '10' 10-SQST-511 50 39 30 24' 5 11 Y, x15 106 12' 12-SQST-411 24 18 13.5 10.5 4 11 ~x15 104 12' 12-SQST-511 39.5 29.5 22.5 18 5 11 ~x15 122 14' 14-SQST-411 20.5 15 11 8.5 4 11 ~,x15 116 14' 14-SQST-407 30.5 22.5 17.5 13.5 4 7 ~x15 158 14' 14-SQST-511 33.5 25 19 14.5 5 11 ,x15 138 16' 16-SQST-411 17.5 12.5 9 7 4 11 ~,x15 128 16' 16oSQST-407 26.5 19 14 11 4 7 ~,x15 176 16' 16oSQST-511 29 21 16 12 5 11 ~x15 153 16' 16-SQST-507 43 32 24.5 19.5 5 7 Y, x15 214 18' 18-SQST-411 15 10.5 7.5 5.5 4 11 ~/,x30 147 18' 18-SQST-407 23 16.5 12.5 9.5 4 7 ~,x30 201 18' 18-SQST-511 25 18 13 10 5 11 Y, x30 175 18' 18-SQST-507 38 28 21.5 16.5 5 7 Y, x30 243 20' 20-SQST-411 12.5 8.5 6 4 4 11 ~,x30 173 20' 20-SQST-407 20 14.5 10.5 7,5 4 7 Y, x30 160 20' 20-SQST-511 21.5 15.5 11 8 5 11 Y, x3O 191 20' 20-SQST-507 33.5 24.5 18.5 14 5 7 ~',x30 266 20' 20-SQST-607 51 37 28.5 21.5 6 7 ~,x30 312 25' 25-SQST-411 8 4.5 2.5 1.3 4 11 lx36 238 25' 25-SQST-407 13.5 9 6 4 4 7 lx36 266 25' 25-SQST-511 14 9.5 6 3.5 5 11 lx36 231 25' 25-SQSToS07 23.5 16.5 11 8 5 7 lx36 324 25' 25-SQST-525 33.5 24 t7.5 13 5 .25 lx36 437 25' 25-SQST-607 36 26 19 14 6 7 lx36 404 30' 30-SQST-407 6 4 2 1.2 4 7 1 x36 313 30' ~) 7 5 2 NR 5 11 1 x36 274 30' ~,, 17 11.5 7.5 4 5 7 lx36 398 30° 20 15 12 7.5 5 .25 lx36 537 30' 30-SQST-607 27 19 13 8.5 6 7 lx36 467 30' 30-SQST-625 40 28 20.5 15 6 .25 1Y, x48 630 ~,~,~' 35-SQST-607 19.5 12 7.5 4 6 7 1x36 538 .:.. 35-SQST-625 24 16.5 11 7 6 25 1Y, x48 726 '~, 40-SQST-607 11 8 3.5 NR 6 7 lx36 614 40' 40-SQST-625 13 9.5 5 2 6 .25 1 '/,x48 802 SQSP - pad Allowable EPA Nom. Wind Velocity HeigM Ordering wrl .3 gust Shah Size Anchor Wt./ Ft. Number 70 80 90 100 Dim Ga BoltSize Lbs. 20' 20-SQSP-511 20.5 14.5 10.5 7,,5 5 11 ~',x30 191 20' 20-SQSP-507 32 23 17~5 13 5 7 Y~30 266 20' 20-SQSP-607 48 35 27 20.5 6 7 Y, x30 312 25' 25-SQSP-511 13.5 9 5,5 3~3 5 11 lx36 231 25' 25-SQSP-507 22.5 15.5 10,5 7.5 5 7 lx36 324 25' 25-SQSP-525 32 23 16~5 12.5 5 .25 lx36 437 25' 25-SQSP-607' 34.5 25 18 13.5 6 7 lx36 404 30' 30-SQSP-511 6.5 4.5 1.9 NR 5 11 lx36 274 30' 30-SQSP-507 16 11 7 3.8 5 7 lx36 398 30' 30-SQSP-525 19 14.5 11.5 7 5 .25 lx36 537 30' 30-SQSP-607 26 18 12_5 8 6 7 lx36 467 30' 30-SQSP-625 38.5 27 19,5 14~5 6 .25 1Y, x48 630 35' 35-SQSP-607 18.5 11.5 7 3.5 6 7 lx36 538 35' 35-SQSP-625 23 16 10,5 6.5 6 .25 1Y, x48 726 40' 40-SQSP-607 9.5 7 3 NR 6 7 lx36 614 40' 40-SQSP-625 12.5 9 4.8 1.9 6 .25 1Y, x48 802 NOTE: !; I H p-c "H" SQST-tenon sG> sT 5o'-7 -T- SQSP-pad SQUARE STRAIGHT TENONED STEEL POLES Optional Adaptor 2" Tenon (2.38" O.D.) Handhole Wil~ / Base Covers *~°V°" Anchor Bolts 11ff -© SPAULDING/WHITEWAY T e 'n I 597 ATI ANTAI APPLICATIONS Building facade, recreational areas. accent fighting, small 'parking areas. swimming pools, tennis courts. and security lighting. CONSTRUCTION FEATURES Optical Housing -- One-piece heavy-duty cast alu- minum with flanged hood to portect the regressed lens. Built-in cast cradles provide rigid alignment of reflectors. Incorporates side door for access into lamp compartment. Lens Assembly -- Extruded aluminum frame, clear, flat. tempered glass lens and high temperature gasket seal lamp compartment from moisture, dust and insects. Optics -- Reflector is two-piece, aluminum, symmet- rical half sections. with anodized finish. Identical reflector halves, combinations of specular, semi- diffused and diffused finishes, are utilized to provide up to six beam spread patterns. Ballast Housing -- The heavy duty cast aluminum housing provides excellent heat dissipation and maintenance ease. A rear cast aluminum housing cover, secured by (4) captive stainless steel screws, fully exposes all electircal components for servicing. A weatherproof and thermally controlled cable strain relief connector allows use of 75"C rated cords. All luminaires are equipped with 3' length #14 AWG/3 conductor type SOW-A prewired cords. Index and Mounting -- All units are equipped with a vertical degree calibrated quadrant plate and reposi- tioning device. A single index nut seats quadrant plate and provides a positive repositioning stop, returning luminaire to original aiming angle. A %" thick steel trunnion (yoke) bracket is secured by two pivot locking screws. Optional crossarm mounting fitting with horizontal degree scale or a 2" pipe slipfitter assembly is available. Integral Ballast -- Starting rated to -20"F ballast. Metal Halide ballast is constant wattage autotrans- former (CWA) type. High Pressure Sodium ballasts are constant wattage autotransformer type using an electronic starter circuit. Lampholder -- Enclosed mogul porcelain socket with spring loaded, nickel plated center contact and reinforced lamp grip screw shell. High Pressure Sodium sockets are pulse rated. Lamps -- Accommodates all wattages up to and including 400 w,~tt Metal Halide and High Pressure Sodium lamps. Finish -- Durable baked-on polyester paint finish is available in 10 standard colors. For other finishes, consult factory. Note: Designed for below-horizontal aiming only. Consult factory for upward aiming. Cast Aluminum Housing Integral Ballast Cast Aluminum Ballast Box End Cover 17 Sq. Effective Projected Area: 2.1 Sq. Ft. SPAULDING SQST - tenon 12' 12' 14' 14' 14' 16' 16' .16' 16' 18' 18' 18' 18' 20' 20' 20' 20' 20' 25' 25' 25' 25' 25' 25' 30' 30' 30' 30' 30' 30' ~,,~5' "FF" Allowable EPA Wind Velocity Ordering w/1.3 gust Shah Size Anchor Wt./ Number 70 80 90 100 Dim Ga BoltSize Lbs. 10-SQST-411 32 24 18.5 14.5 4 11 Y, x15 91 10-SQST-511 50 39 30 24' 5 11 Y, x15 106 12-SQST-411 24 18 13.5 10.5 4 11 Y, x15 104 12-SQST-511 39.5 29.5 22.5 18 5 11 Y, x15 122 14-SQST-411 20.5 15 11 8.5 4 11 Y, x15 116 14-SQST-407 30.5 22.5 17.5 13.5 4 7 ~,x15 158 14-SQST-511 33.5 25 19 14.5 5 11 Y, x15 138 16-SQST-411 17.5 12.5 9 7 4 11 Y, x15 128 16-SQST-407 26.5 19 14 11 4 7 ~x15 176 16-SQST-511 29 21 16 12 5 11 ~,x15 153 16-SQST-507 43 32 24.5 19.5 5 7 ~x15 214 18-SQST-411 15 10.5 7.5 5.5 4 11 Y, x30 147 18-SQST-407 23 16.5 12.5 9.5 4 7 '/,x30 201 18-SQST-511 25 18 13 10 5 11 ~',x30 175 18-SQST-507 38 28 21.5 16.5 5 7 Y, x30 243 20-SQST-411 12.5 8.5 6 4 4 11 -Xx30 173 20-SQST-407 20 14.5 10.5 7.5 4 7 Y, x30 160 20-SQST-511 21.5 15.5 11 8 5 11 Y, x30 191 20-SQST-507 33.5 24.5 18.5 14 5 7 Y, x30 266 20-SQST-607 51 37 28.5 21.5 6 7 Y, x30 312 25-SQST-411 8 4.5 2.5 1.3 4 11 lx36 238 25-SQST-407 13.5 9 6 4 4 7 lx36 266 25-SQST-511 14 9.5 6 3.5 5 11 lx36 231 25-SQST-507 23.5 16.5 11 8 5 7 lx36 324 25-SQST-525 33.5 24 17.5 13 5 .25 lx36 437 25-SQST-607 36 26 19 14 6 7 lx36 404 30-SQST-407 6 4 2 1.2 4 7 1 x36 313 7 5 2 NR 5 11 lx36 274 ( "17 11.5 7.5 4 5 7 lx36 398 20 15 12 7.5 5 .25 lx36 537 30-SQST-607 27 19 13 8.5 6 7 lx36 467 30-SQST-625 40 28 20.5 15 6 .25 1Y, x48 630 35oSQST-607 19.5 12 7.5 4 6 7 lx36 538 35-SQSTo625 24 16.5 11 7 6 .25 1Y, x48 726 40-SQST-607 11 8 3.5 NR 6 7 lx36 614 40-SQST-625 13 9.5 5 2 6 .25 1Y, x48 802 SQSP - pad Allowable EPA Nom. Wind Velocity Height Ordering wrl .3 gust Shah Size Anchor Wt./ Ft. Number 70 80 90 100 Dim Ga BoltSize Lbs. · 20' 20-SQSP-511 20.5 14.5 10.5 7.5 5 11 Y, x30 191 20' 20-SQSP-507 32 23 17.5 13 5 7 Y, x30 266 20' 20-SQSP-607 48 35 27 20.5 6 7 Y, x30 312 25' 25-SQSP-511 13.5 9 5.5 3.3 5 11 lx36 231 25' 25-SQSP-507 22.5 15.5 10.5 7.5 5 7 1x36 324 25' 25-SQSP-525 32 23 16.5 12.5 5 .25 lx36 437 25' 25-SQSP-607' 34.5 25 18 13.5 6 7 lx36 404 30' 30-SQSP-511 6.5 4.5 1..9 NR 5 11 lx36 274 30' 30-SQSP-507 16 11 7 3.8 5 7 lx36 398 30' 30-SQSP-525 19 14.5 11.5 7 5 .25 lx36 537 30' 30-SQSP*607 26 18 12.5 8 6 7 lx36 467 30' 30-SQSP-625 38.5 27 19.5 14.5 6 .25 1Y, x48 630 35' 35-SQSP-607 18.5 11.5 7 3.5 6 7 lx36 638 35' 35-SQSP-625 23 16 10.5 6.5 6 .25 1Y, x48 726 40' 40-SQSP-607 9.5 7 3 NR 6 7 lx36 614 40' 40-SQSP-625 12.5 9 4.8 1.9 6 .25 lY, x48 802 NOTE: Spec~ Coloc F, oeoRlerlnglnformationonopttorts&mseePage16ofthe Fodure EpA ts conl:mted at 2' above toP of Pole, Padr, ount 3' above toP ol Pole- SQST-tenon - SQSP-pad SQU~,RE STRAIGHT TENONED STEEL POLES Optional Adaptor .2" Tenon (2.38" O.D.) Handhole With Cove~ ~'~'~E3' .,K//,.__ Anchor B°ltsrs 597 TI VERTICAL MOUNTING BRACKETS TENON MOUNT SERIES Luminaire Slipffiter Order Mounting Center A Size Bracket WtJ Arrangement (In.) (In.) EPA Lbs. 2 light 27 2 .5 15 2 light 40 2 .6 22 215-B3 3 liaht 13){ 2 .5 23 216-B3 3 light 20 2 .9 31 217-B3 3 light 20 2 .6 21 219-C3 3 light 30 2 .8 27 215-B3Y 3 light 20 2 .6 20 219-C4 4 light 30 2 1.1 45 216-B4Q 4 liaht 40 2 .8 37 NOTE: Spedfy Co/or of pohzes~r p~n~ finish. 2'Sr, prmeraccepts2'p~pe(23~')te,o~. Models 215-B3Y 3 light at 120 -B4Q 4 light at 90 CLAMP-ON SERIES Order Mounting Number Arrangement 282-B I light 282-B1 1 light 282-B2 I light 283-8 2 light 283-B1 2 light 283-B2 2 light NOTE: SpedfyC~lor o~pobesterpaintfinish. Pole Size Round Square Bracket WtJ (In.) (In.) EPA Lbs. 5-7 4-5 .5 17 3'/z-5 3-3){ .4 15 7-12 6-8){ .6 23 5-7 4-5 ,8 25 3Yz-5 3-3){ ,7 23 7-12 6-8){ .8 30 Brad~slsarefab~fmm2"sledp~pe. CAR LOT SPECIALTIES Order Descdption EPA WtJLbs. Number Amhitectural Adjustable Clamp Bracket AACB--4 for 4"_ pole .5 -10 AACB-5 for 5" pole .5 12 AACB-6 for 6" Dole .5 15 FLB-24 Roodlight bracket for Dole mounting CLB-2 Front Row bracket for 2 area lights 2.4 48 2C-Round 2C Coupling for round poles - - 2C-Square 2" Coupling for square poles - - NOTE: FLB b~is3'sq. sled wiffi2hde plate lor mourdjng Ct,S~ls4"xS'sledlu/~andboltstof~ol SPAULDING Model 215-B3 /,I Models 217-B3 or 219-C3 Model 219-C4 Model 282-B ~ Model 283-B -,~ Order Number SB-2 SB-3 SB-4 SB-240 SB-3-30 NOTE: I II FLEF24 2" Tenon "~' 2C Coupling 2" Internally Threaded Coupling Description A-Luminaire Length Bracket WtJ Center (In.) (In.) EPA Lbs. Twin 20 26 .9 16 Triple 20 46 1.6 27 Quad 20 66 2.3 38 Twin at 40" 40 46 1.5 25 Triple at 30" 30 66 2.2 36 597 WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 SPEC SECTIONS: SC-15 PART C RACEWAYS ITEM 1 ITEM 2 ITEM 3 ITEM 4 ITEM 5 ITEM 6 ITEM 7 ITEM 11 ITEM 13 ITEM 14 RIGID METALLIC ALUMINUM CONDUIT PVC METALLIC CONDUIT RIGID NON-METALLIC CONDUIT LIQUID-TIGHT FLEXIBLE CONDUIT LIQUID-TIGHT FITTINGS CONDUIT BUSHINGS CONDUIT BODIES CAST METAL BOXES TAPE PRODUCTS SUPPORTING DEVICES SPECIFICATIONS ~,,~LL.OY: 6063 aluminum altoy. T-1 temper. (Former designation T-42) SPECIFICATION COMPLIANCE: Federal Specification tNW-C-540c. Underwriters' I =horalories UL-6, latest mvisk)n. American Standard Association (ASA) C 80. 5. THREAD PROTECTORS: Aluminum Rigid Conduit is shipped With thread protectors, whicah shield thremds, and simplify size selection. AD%(ANTAGES OF ALUMINUM RIGID CONDUIT Aluminum rigid cone~ offers the electrical industry all ~e inherent physical advantages of ~is light .metal aZ a cost competitive with ordinary conduit. UGHT WEIGHT The light weight of aluminum in combination with high strength makes the aluminum ideal for any conduit installation. A 10 foot length of 4 inch aluminum rigid conduit. weighs only 38 pound~:~::''~ while a comparable ~ of steal conduit we~ ~, -.. 98 pounds. W'mq aluminum conduit a~'~-! "" ,. JRROSION RESISTANCE Aluminum conduit resis~ most corrosive atmos- pheres and industrial environments tha~ usually tack other types of metallic conduit. In these appli- cations, aluminum requires no painting or replace- ment~ resulting in considerable savings in rnainte- nance costs. LOWE~,GOST Aluminum conduit is competitive in material cost with steel conduit. Because of the ease of handling and fabricating aluminum in the field, ttle installed costs of aluminum conduit am madly lower than ordinary conduit. ATTRACTIVE APPEARANCE Aluminum prooe. d~ a ~ d~y good appear; NONSPARKING :. ::"- NONMAGNETIC Nonmagnetic aluminum conduit reduces power loss due Io voltage drop, resulting in power saving throughout rrfe of installation. EASE OF INSTALLATION Aluminum conduit can be readily cut, bent, or threaded on the job, and it requires no special tools or installation equipment. In installations using large size conduit, ease of field fabrication is of RECOMMENDED INSTALLATION PROCEDURES The conventionaJ tools and practice~ used on o~dinan/con- dui~ can be utilized on Aluminum Rigid CondulL CUTlING: A hacksaw is recommended to cu~ sizes 1%" and smaller. Larger sizes can be cut with power cut-off equipment. BENDING: Standard EMT bendere, one ~ iarger than the size of the conduit, should be used on conduit sizes 1' and smaller. For sizes over 1', conventional equipment is recorn- mended. ,3dREADING: Sharp dies and conventional curling oil should zsed for aluminum conclu~ Excellent results can be o~- -,~ned with a solul~on of 50'/, lard oil and 50% kerosene. FFTTINGS: Aluminum f'tdngs are recommended; however, cadmium plated or galvanized fillings are satisfactory for most installations. IN CONCRETE: Aluminum conduit can safely be embedded in concrete where chlorides are not present, whether the in- staJla~on is below or above grade. The 1963 revision to the ACI Building Code 318 published by the American Conca"ele InstilsJm pmhiits ltm addition of additives containing cadciurn chk}ride to any ooncrete that may be in contact with prestre~ sing steel Ak,vrinum conduit should not be directly iml:N~ in con~a"~ie containing soluble chlorides, such as caldurn aggregates. Aluminum conduit can be safely installed in con- crete cormairing ¢Norides if an adequate protective coating of IN SOIL OR CINDERS: Aluminum conduit or steel conduit, when buded it soil or dr.:lers, shouid be treated with aproteo- tire coating of biNmastic or asphalt-base pint, or wrapped with plastic tape. Tride 1/2' 3/4" 1' 11/4' 11/2' 2' 21/2' 3' 31/2' 4' 5' 6' ALUMINUM CONDUIT-TOLERANCES AND SPECIRCATIONS b NomindWt.. !k~,~ L,m'qffi 101 I~Bundk iBdL Bm&e 1.562' .61 # 10 250 703# 1.625' 31# 10 250 935# 2,000' 1,25~ 10 200 1090.f 2,062' 1.89.~ 5 100 716# 2.062' ~ 5 100 887# 2.125' 3.46.~ 5 45 533# 3.250' 9.144. -- 20 492# 3,50r 14.21 -- 20 700# 3,75G' 24.2.~ -- 8 383# 4.1XIO' 32..lt -- 6 378~ COMPARATIVE INSTALLATION LABOR - BRANCH CIRCUIT W[R[NG - MAN HOURS FER 1 O0 FT. 7,8 6.4 3,5 5.5 6.4 10.6 82 6.2' 3,7 53 6.7 11.1 11.2 92 50 82 92 15,2 11.8 93 5,4 8.6 9.7 16.0 COMPOSITION OF ALUMINUM CONDUITALLOY How to specify Perma-Cote,' Imcote, A!umi-Cote and Perma-Cote Supreme PERMA-COTE , I. Prior to the application of the PVC coating. the galvanized rigid steel condutt shall conform to Federal Specifications WW-C 581E and ANSI Standard C80-1. and UL Staudarcl #6. 2. The couduit will be hot clip galvanized inside and out. 3. The galvanized surface will be cleaned prior to application of an epoxy based primer to insure a superior anchor for the PVC coating. 4. The PVC coating shah have a notninal thickness o1'40 znils (.040") except where part applica t ion or configurat ion dictate otherwise. The coating will have a maximun~ thickness o1'45 mils. 5. The PVC coating is applied to the conduit using the ~uidized bed n~ethod and will be free of gross, non-uniform characteristics and the bond bclween the PVC and the conduit shall be greater than the tensile strength of the plastic. 6. A coupling with sleeve extensions will be supplied separately for each piece of conduit. All coupli$~Rs and fittings (where practicable) will have sleeve extensions equal to the diameter of the conduit to a maxhnun~ length of 2". 7. All condulets and flttini~s associated with the raceway systen~ shall be PVC coated with a nonainal thickness of 40 mils except where part application or configuration dictate otherwise. All Forn~ 8 condulets will be supplied with stainless steel screws with encapsulated heads. All threads on conduit, nipples and elbows shall be coated with a two part chemically cured urcthanc coating. The finished conduit product shal[ conforn~ io NEMA Standard RN l and UL laboratories Specificat ion ~6. The coated conduit shall carry evidence that it is listed by UL. PERMA-COTE SUPREME 'r!'~is product shall confbrn~ tu (he above specifications. In addition tile following specifications apply: 10. The interior of all conduit and fittings will be coated with a two part che~nically cured uretltanc coating at a 2 tail t~orninal ttiickncss. l 1. The urethane coating applied to the interior of the conduit will not Ilake or crack during field bending. 12. All thru Iced conduit fittings associated with a raceway will be internally coated with the two part urethane coating at a 2 rail nmnlnal thickness except where code or fitting functionabilLty prohibit. 13. All fenlate threads ofcouplings and fittings shall be coating witll a two part chenHcallv cured urethane coat ing. Perma-Cote DIMENSIONS OF RIGID STEEL CONDUIT Prior Io Coaljng) Stze ,/~ ,, 3/4,, Outside Dlameler (inches) .840 1,050 1,315 1.660 2.375 2.875 3.5OO 4.000 4.500 Inside Conduit Wall Weight Per 100' DIameter Thickness With Coupring (Inches) (Inches) (Ibe.) ,622 .109 .824 .113 109 1,049 .133 165 215 1.380 .140 1,610 .145 258 2.067 ,154 352 .203 567 2,459 3.068 .216 3.548 .226 714 4,026 .237 860 ! 000 ## 1V2" 2" 2Vz" 3" 31/2" 5,563 5,047 .258 6.0~ .280 1320 1785 COATING PROPERTIES Property Hardness (@ 23,0°C :t: 1,0°C) Shore A 7" Shore D ':l'ensile Slrenglh Elongation Abrasion Bendabilily Adhesion Test Dat~ 80 min 40 min 3500 nom 200 min 200: no failure 9: no Holiday Greater than the cohesive strength of the coating. Ft_ammability Dielectric Strength Outdoor Weathering Artificial Weathering , Salt Spray Brittleness Temp. Temperature Limits (recommended "in place"} Self extinguishing 400 min 9: no effect 3000: no effect 3000: no effect -18 -40to +80 Unit psi pct hrs radius" NEMA Standard 75 25 20O0 200 200 9 same vlmil mos ~ 325 hrs 4 t 000 hrs °C - 15 ASTM Test j 0-2240-81 D-2240-81 D-638-86A D-638~86 G-6-83 G- 10-83 (RN1-3.8) D-568-68 D-149-81 G-11-69T G-23-81 B- 117-64 D-1790-83 Why Perma-Cote Supreme? Perrna-Cote Supreme was developed to enhan. ce an already superior product by providing excel- tent corrosion p,-otection to Lhc interior of the conduit system. This tough two ' part polyure- lhane coating was designed specifically ll~ose areas w!~ere lhere is a high probability af inlernal system corrosion. TIlls inlernal coal ing applied to Rern~a- Cole 40 rail producis gives you the ultinqate in corrosion pro- Icc/ion. The smool h coal reduces fi'iction allowing easier wire pullh~g. What is Perma-Cote Supreme? It is a two part. chemically cured polyurethane coating applied Internally to 40 roll Perrea- l Cote conduit. couplings. elbows and hollow fittings. The coating is applied at a nominal 2 rail thickness and is also applied to the illreads to h'nprove corrosion protection. BendinU The llexibility and adhesion properties of the PVC coating allows you to field bend wlthotst cracking or flaking of the coating. The bond between the PVCjaCRel anti nteta} exc:eeds Ihe tensile sl rengl h of t!~e plastic ilsclf. Thcrelbre, with this super strong thermal bond. normal radius bends can be lbrmed without wrinkling or bond failure. (Both Greenlee and Enerpae manul~cture bending tools that are Compatible with Penna-Cote conaltair -- see installation guide). Handting Reasonable care should be exer- cise. d in lhe movement, storage and installation of Perroe-Cote Industries' prodtlcts. The service life will be greatly enl~anced ii' the coating ls flee from da~qna,ae when installed. Sirap wrenches are all that are need- ed to assemble tl~e system. Should the protective ceating be accident- ally damaged, it can easily and readi- ly be repaired with our touch-up con~pot~nd. Perrna-Cote conduit is easily threaded using slandard tools. Do not store near high hca~, solvents or where'susceptible to abrasion. Compliances and Listings Perroe-Cole PVC coated galvanized conduit is listed witl~ Undcrwrit. ers t.aboramrles. The galvanized cc~nduit conforms to FederaI spe~: il'icatlons WW-C-581 E, UL standard #6, and standard C80.1 prior to coating. Perma-Coi. e prodryers conl~orm to National Etcc~ rtcat Mam,,facturers Association {NEMA) standard RN-1. SCHEDULE A THIN WALL. IN-DUff CONDUIT Carlon FV-Duit, Schedule A, is 90°C UL listed for underground encased use. Conduit conforms to NEMA TC-2, UL-651 & WC- 1094A Stlndardr, All join~a shall be solv~rrt camcrated in ~-oordance with recom- mendations of the manLrf~Cturer. w'r. P~R ]0(Y FEET PER NOM. SIZE CATALOG NO, O,O. I.D. WALL, )LAIN END IUNDLI[ %' 4II0S .140 .720 ,060 11 I00 )/,' 49107 1.050 ' ,930 .060 14 100 1' 49108 1.:$3i 1.195 ,1~.0 la 1oo 1%' 49109 1.6643 1-520 .Q}0 ;J~ 50 11/~- 41110 1.900 !,1¢0 .0~0 34 50 2' 49111 2.315 2175 ,10O 53 10 3' ' ~9113 1,500 3.250 .125 9S |0 4' 4.t11E 4.~30 4.200 .1S0 1,55 1O SCHEDULE 40 HEAVY WALL, IN-DUIT PLUS® Carlon PV-Duit Plus, Schedule 40 conduit, iS 90=C UL listed for aboveground and underground uses. Conduit conforms to WC-1094A NEMA TC-2 and UL-851 Standards. It is UL listed in conformity with Article 347 of the National Elec- trical Cocle. PV-DUIT PLUS products are manufactured from Carlax 300, an improved PVC compound ~hat substandally reduces smoke and HCL emissions in a fire ~ituat~on end offers superior weameral3ility. All joints shall be solvent cemented in accordance with fie recommendations of the manufacturer. w'r. PER 100' NGM. SIZE CATALOG NO. 0.0. I.D. WALL PLAIN ENO t/~- 49005 .84~ .522 .109 17 3/,' 41007 1.0~0 .B24 .113 23 1' 49008 1.315 1.04t .133 34 1 s./, - 49009 1.6~0 1.380 · 140 2' 49011 2.375 _ 2-0~7 .154 21/a` 4g012 2.175 2.469 .2O3 3' ~9013 1-500 3.o&S -215 155 3 s/~.' 4tOl& 4,000 3.5.48 . ,226 181~ 4' 49015 4.500 4.026 -337 5' 49016 5-563 5.047 ~158 298 6' 41017 i.12l k.015 ,280" 387 FEET FiR ' SUNDLE 100 60 50 50' 10 10 10 l0 t0 10 SCHEDULE 80 EXTRA HEAW WALL, PV-DUIT 'CONDUIT Cadon PV-Duit, Schedule 80 Conduit, is dlmigned for aBove- ground and under round applications where an extra heavy Wall PVC is neeciVicS. Typical applications would include those subject to physical el)use such as pole dsenl. Schedule 80 is manufsm'ured from Cadon 2000 Compound, is UL listed and conforms to UL and NEMA Standardm. WT, PER 100' IrE. it PER NOM. :~IZE CATALOG NO. 0.D. .I.D. WALL PLAIN END BUNDLE ~' 41408 .140 .54a .147 21 100 s/,- 41407 1.050 .YA2 l"' 49408 1.311 .957 .17g 42 !00 11/,~' 494~}. 1.660 1,278 .191 r~ 50 1% ' 494 l0 1.900 1.500 .200 70 50 2' 49411 2.37S 1.939 .218 ~ I0 2%' 41412 3.175 2-323 .216 145 10 3" 49413 3.500 2.~30 .300 194 10 4' 49411 4 500 3.826 -337 2e,4 10 5' 41416 5.$63 4113 .315 ~13 10 "Meets NEMA Standards but net UL Llshtd. One Ho~ Two HO~ parr MO. ESYeD ½ 100 EiTIG 1 Y, 100 Et/81 M 100 l$71H I ~ 100 ~97$F 1 100 iSTBJ 2 100 NOTE: These products conform to NEMA TC-2, F~lsd Specifiesdon WC-1094A snd UL-O51 StandNds. ,.._,~.,~w._,_, SNAP STRAP .CONDUff' WALL HANGER New. hlgh-suength Cl~mp sdvel bowing problems ru~ul~ing from the eXp~naio~ end contr8ction of conClUil cauEKI lay va~f' r~mper,ture changes. Mount wiffi Ilanda,-d wflIU~n~r. -"~ lIQUID-TIGHT ... ~ ~ SPECIRGeO'IONS Type._.U__L~qu!d-.~gh~ ' '~'--. ! ..: FEATURES NOTE Conforms m ~e ll~ov~s~orts of Arlide351 dl~e National Eietlncal C.~,~e unc~"r 'hquzb-ffJ_c?:t FlexUre Conczuir..'.S~.es ~.-II~ouc~ ]~.:~' fzaveacormnuous coppet~o:.mcZv. mel~:.~ZnmZrzecore. 5,:'~ t.E~,.T~ EFUquid-~i~h~ z~' must be insta l~ecl using a separate g;c~o~d wim ~o ccmformtoAmcle35L Cm to UL. 360: LD.,/ile#1~8759. /~prou~3y Canac~ianStan~rcts/~sod~ion; cemfica/ion -~1.5538~ I 1. For use in limitell .~oace wt~ereextra fleXihi|ity iS neec2ecl. Z Quality assured - inspc, ff_-~ and testeel eightlimes from D.-~'ff~ng to enct ~ anti lenga~s indicate~ are s?.anclard pmcluc~. For sizes ~ ~ lencj!~s nol: listect, please cor~_:~r me fa~.. Availal~leFrom: :~A=~n Bpre~_'_~_SUeetLongBe,~CAgOBlO 12131979461 Liquidtight Connectors · ~qu~ky, t/Ra~nt~)htGmt~ · Grounding type. · S.~e ~ ~ ~ Nut "~ F~ N~ ~24~ · U.L. ~ 1~ ~r~w~u~ ~ ~d ~ ~e qui~ ~ m d~r~ ~ m~~alin ~ n~. PATENTED (~l ~s mis ~e) o-Z ,/CC.13NEY 100 26 26 53 113 178 471 649 10'Z5 ~05 Dmmemm~Onl In JOl'*de'V'f ~ Incnei Tra~e rilelee ~e Numl~r |ncfles A ~ C O ~T 1 '~ 2s~ %~, 29/,~ 3~ ~T 2'~ ~, 1 ~ ~LT 5 16 1% 14 4Q-e250L mru 4Q~SCXX. Turnb~ Ra~iu~ Wte Size GMf~ Nm Min. i. 1%m 14 4 1~,l 14 4 I~A, 14 4 1~, 14 4 61 1~ 6 1~ 114 1~ 8 1~ 149 3tX. I 4~ 1216 ~ . 1 ~ 2191 · ULm ~e 91z9 .i CF-2 [ LISTED[ Fie #14817 E6561 threaded Rigid Conduit and IMC Grounding Bushings S-FEe Sc/ c Wire Size Dimensions Lbs. Ctn. Catalog No. Size Min. M~x. A 5 C Per 100 Qty. '/2 14.7 3/, 9.9 ;/4 16.2 13.0 19.3 19.0 25.1 24.8 31.1 Insulated 150° Temperature Rating--with Soldedess Lugs-- Malleable iron Gee-SOL-4 ,/, 8.4 GIi~5OL-10 GIB-75L-4 GIB-TSL-10 IB-1OOL-10 1 GGIB*125L-4 IB-125L-10 Stcl. Pkg. 14 SOL 4 STR 1V' ~5/~ 15/,, 50 500 14 SOL 2/0 STR 1 V" W"' 1,3/,, 25 100 14 SOL 4 STR 13/i ,5/~ 17/i, 50 500 14 SOL 2/0 STR 13/5 ,5/~ 121/32 25 100 14 SOL 4 STR ls/l 5/I lV- 25 250 14 SOL 2/0 STR 15/i 5/= 21/32 25 100 1 '/4 14 SOL 4 SIR 2V1~ '/~ 1'/== 25 100 1V4 14 SOL 2/0 STR 2V- ~V~" 2V, 25 100 1V~ 14 SOL 4 STR 2~/. 3/a I~5/,e 10 100 1V~ 14SOL 2/0 STR 23/= ~/~ 2u/52 10 50 GIB-20OL-4 2 14 SOL 4 STR 27/, 5/4 2V,, 38.0 5 50 GIB-2OOL-IO 2 14 SOL 2/0 STR 27/e a/4 2~t/3; 44.3 5 50 GIB-250L.-4 2'/2 14 SOL 4 STR 3V~ ~/: 2'/2 66.7 5 25 GIB-250L-10 2V2 14 SOL 2/0 STR 3'/2 ~/e 3 73.0 5 25 GIB-250L-25 2'/2 6 SIR 250 STR 3'/z 7/, 3tshz 85.5 5 25 GIB-3OOL-4 3 14 SOL 4 STR 4~/. 2/e 2W~; 81.7 1 5 GIB-3OOL-IO 3 14 SOL 2/0 STR 43/~; ~/~ 3~/~ 88.0 1 5 GIB*3OOL-25 3 6 STR 250 STR 4~/32 7/5 33/~ 100.5 1 5 GIB-350LA 3Vz 14 SOL 4 STR 423/3; 1-'/:~ 3'/~ 77.2 1 5 GIB-350L-10 3'/2 14 SOL 2/0 STR 425/32 l:/n 3'9/52 83.5 1 5 GIB-350L-25 3'/; 6 STR 250 STR 4u/, 1~/, 4'/,~ 96.0 1 5 GIB-4OOL4 4 14 SOL 4 STR 57/~ II/=2 33/, 106.7 1 5 GIB-4OOL-IO 4 14 SOL 2/0 STR 57/:z 13/32 32r/s; I13.5 1 5 GIB-4OOL-25 4 6 STR 250 STR 52h2 1~/52 4s/~6 126.0 1 5 GIB-~OI.-4 5 14 SOL 4 STR 65/~, 1 ',/, 3zf/32 176.2 1 5 GIB-5OOL-10 5 14 SOL 2/0 STR 6s/,a 1'/3 4~/, 182.5 1 5 GM-500L-25 5 6 STR 250 SIR 63/,~ 1'/, 4z/. 195.0 1 5 GIB-6OOL-4 6 14 SOL 4 STR 7;/, 1 '/, 4~/~; 263.2 I 5 GIB*6OOL-10 6 14 SOL 2/0 STR 7'/. 1'/, 4ap, 269.5 1 5 GIB-600b25 6 8 STR 250 STR 73/, 1'/~ 53/= 282.0 1 5 Discount Schedule CF-2 Refer to Pncing Index f~ Prices. ( )ApR h to n 1701 W Wellington Ave. C,l'~cago. Illim:;x~ 60657 100 ' 39Vd 128: ~' 88, 9 /30 Z FM7'" Gr~loy"-Iron and A!umin,~m Unilet" Conduit Bodies with Wedge-LokTM Clip Covers For Use with Rigid Steel, Rigid Aluminum, and IMC ~nduit ~ Appmt~ FM7 co~lt ~es, ~ve~ and gaskets have the same appllcatlo~ a~ installation dlme~ns as GrouseHinds Form 7 ~ffin~. Equivalent FM7 a~ Fo~ 7 items are completely interchange~le. Appleton FM7 Conduit Bodies NOTE: Refer to pege 26 for Wldng Capacity Tibia C Hub Size Grayloy-ko~ Aluminum Graytoy-iron 1/2 C17 CII-~IL 3/4 C27 C274A I C31' C374A 1-1/4 C47 C47-8A 1-1/2 C57 C57-8A 2 C87 C8'7-8A 2-1/2 CTT C'/7-8A 3 C87 C87-SA 3-112 LB LL LR T Aluminum Grayloy-iron Aluminum Grayby-iron Aluminum Qraytoy-lron Aluminum LB17 I,B17-eA LL17 LL17-SA LR17 LFI17.,SA T17 T17,.SA LB47 LB47-eA LL4? LL47-1A. . LRI7 LR47-1A 747 T47-1A L.N7 I. J674A LL87 LLB7-eA LRII' LFIIT-IA T67 T67-IA 1,077 UB77-BA LLTT -- LRT/ -- T77 -- LB97 -- ', LL91' -- LRfT -- T97 -- LB107 -- ! LL107 -- LR101' -- T107 -- L '~ ......TA I TB i X ~ i _ ._ ,T,_j . 0rlytoy, kl:m Aluminum t Grayk y-lro~ Aluminum Ollyloyqrml Numimlm iClrlytoy-lron Aluminum ': ....... I L17 L17-SA ' TA17 TA17-SA TB17 TB17-SA ~ X17 X17-SA 1,27 L27-SA TA27 TA27-&A 1127 1127-SA X27 X27-SA 1.37 L37-$A , TA37 TA37-SA 1137 TB37-BA X37 X37-,SA L47 LA7-gA TA47 TA47-BA 1147 TB47-,~k X47 -- LG/ L67-SA TAG7 TA67-SA 1167 TB67-SA X67 -- E Itze Graytoy4ron Aluminum 1/2 E17 E17-SA :3/4 E27 F.27-SA 1 E37 F,,37-SA 1-1/4 -- 1-1/2 -- -- 2 -- -- ,Al~ieton FM7 Blank Covers and Gaskets lax Greytoy-Iron Alumimam Qreyloy-iron Numlnum d2 1701: 170F-SA 170FG 170FG-SA ~d4 270F 270F-SA 270FG 270FG-SA i 370F 370F--SA 370FG 370FG-SA i'-114 470F 470F-SA 470FG 470FG-SA !-t12 570F 570F-SA 570FQ S70FG-SA t, 670F 670F-SA 670FG 670FG-eA ~1/2 870F 870F-SA 870FG 870FG-SA 87OF ~ror--~ 870B 87QFG-SA ~"'~ 970F .91q)F-BA 970FG 970FQ-eA Gasket Steel Aluminum 170 170-~A 270 270-SA' 370 370-SA ' 470 470-SA 570 570-8A 670 670-8A 870 870-SA 870 670-8A GASK571 GASK572 GASK573 GASK574 GASK575 GASK576 GASK578 GASK578 QASK579 QASI(r/9 Schedu~ UD PTtc~ex~p~e, C0Wright 1990 Printed in U.S.A. ( APR bto i701 W. Wetllngto~ Ave. r..,~,caQo, Ironolin eo6~7 Effective January 19943, PAN I Ck ~se-Hinds Cast Device Boxes without Mounting Lugs Multi-Gang Accessories Pg. 3F-17 to 24 F:St FSCt two Gang Tandem Two Gang Tandem threaded Rigid Threaded Rigid ;Ize L # SIze CIL # /2 , ,~17 1/2 FSC17 ~/4 FS27 3/4 FSC27 Dimensions FS & FD Two Gang Threaded Rigid SIze Cat. # Cat. # 1/2 FS12 FD12 3/4 FS22 FD22 I FS32 FD32 FSE Two Gang Threaded Rigid SIze Cat, # 3/4 FSE22 Two Gang Thr Threaded Rigid SIze 3/4 size CaL # Cat. # 1/2 FSC12 FDC12 ~ 3/4 FSC222 FDC222 I FSC32 FDC32 ruse single gang covers only ~ FS Two Size 3/4 T 'L ..... ' .... ~' ' 3 I ~ ' · · ~!~!:.;~ "- ~.' ~'i-i:.',~:~ '~.~:~.e..,,~.....:!!:~!.~:i:',. _~_::.., .'.-;'~.~:y,.,>,~.'.;~;~:; .'~ · t..' ;.:':~ " :ij ;'~::.';':-,.-.'~:~:q'-~::.: [i .';"j.:'.:~:(~:}~,:~?:~::::"::~:~:'~ ,.: '::~';~.. - . .... ~'~~ . ~ ~:~;~,;~,,,,i.". ~d.- ,. · ;?~:.,z~,:~;t~.~'~fJ i~-. mc ..... · .... ' - ~".'T wo gang landera Two gang : 'E~; Hub Hub .erles SIze a d · Series SIze a c ~ h ~/2 7/8 5/8 11/4 1/2 7/8 17/8 1 11/16 5/8 S '4 7/8 3/4 11/2 FS 3/4 7/8 17/8 1 11/16 3/4 ~: ~'/ ' 1 7/8 13/4 1 I 17/8 1 11/16 7/8 1/2 7/8 2 11/16 2 1/2 5/8 .~' FD 3/4 7/8 2 11/16 2 1/2 3/4 I I 2 11/16 2 1/2 7/8 .ugust 1974 ~ 1974, Croup-HInds Company For over 30 years, 3M has been the world's teadin8 supplier of ¢lecmcal tapes:The broad 3M line includes vinyl plastic taps of many kinds, from our stretchier and sticker, aU-weather tape, Scotch brand Super 33 + to our heavy-duty Scotch brand 22 and cold weather Scotch brand Super 88 tapes. 3Nt has glass c~th;~[~erless, rubber, semiconduct- ing and varnish~ cambric tapes for insulating and splicing. Fire-proofing tapes, anti-corrosion tapes and Scotch brand 35 color-coding tap~ are also avail- able. ' Durable 3M tape~ have excdlent resistance to abrasion, moisture, UV rays and many caustic sub- stances. They are compatible with solid dielectric cable insulation. And becau~ they'r~ d~igned with the electrician in mind, they're easy to apply properly ha a wide rang of temperatures, indoors a~d out. Super 33 + Scotch Brarld: Vinyi Electrical Stickier, stretChier and highly conformable. Super 33 + is a premium- grade, 7-rail (0.18 ram) tape that applies well at - 18°C/0°F and 'has an operating range up to 105°C/220°F. Flame retardant, hot- and cold- weather resistant, Super 33+ resists UV rays, abrasion. moisture, alka- li~s, acids and corrosion. ~ Use Super 33 + as a pfi- r mary insulation for wire cable splices up to 6~0 V and for fixture and wir~ splits up to 1 kg. Meets requirm~l~ of ASrM D..3005 T.vI~ I, UL Sl0, HHI-59$C, aml C~_& 22,1, ,,-- ,,.,, ..... .,""r. -,..,. Sins' 33+ 06130 t' x 20' I{IRsss I00 (19 minx6,1 m) 8ssl, s' 33 + IOOF.5 t' x .44' llcm 100 f'19 r~ x 13,4 m) 'lO/c~ $esr 314- 061,12 ti' x 66' 1/cm 100 (19minx20,1 m) 10/c~ laler33+D' 10216 ti'x66; 110I~ I~0 figminx20,/m) 10/cm Ne~e. Other w~Izhm ~ Wnirtbm a,ai~ml:m~ upoe mqumm. · UPC Prefix 054007- To order, FAX 14i00-245-0329 or call T-800-245-3~73 S WO~ ZTsO 8T 'l~t CH 5b~l, TTi~ L <. P fc Rigid MeaLConduit or IMC "K-Clamps" Catalog No. Size Right Angle Type--Hot Dip/Mechanically Galvanized PC-50RA PC-75RA '/, PC4OORA 1 PC-125RA 1 V, PC-150RA 1 PC-2OORA 2 PC-250RA 2'/2 PC..3IX)RA 3 PC.-,lSORA 3'/2 laCJ, OORA 4 .... .. Pe.qmm~t 5 · ', Pc~-e4X~ukl. 6 PC-100PAR 1 PC-125PAR 11/4 PC-150PAR 11/z PC-20OPAR 2 PC-250PAR 21/2 PCo300PAR 3 PC-350PAR 31/2 PC-40OPAR 4 hmllei Type--Hot Dip/Mechanically Galvanized Wt. Lbs. St, Per 100 Pk: 37.0 40.0 42.0 49.0 54.0 71.0 95.0 107.0 120.0 131.0 160.0 195.0 Edge Type--Hot Dip/Mechanically Galvanized PC-75ET 3/4 PC-10OET 1 PC-125ET 1 I/4 PC-150ET 11/2 PC-200ET 2 PC-250ET 21/2 PC-3OOET 3 50.0 5~ 53.0 60.0 5~ 70.0 5~ 82.0 5~ 132.0 2'. 192.0 2'. 194.0 216.0 11 232.0 1{ 63.0 69.0 82.0 95.0 108.0 121.0 153.0 214.0 Dimensior~. UNC A B .. C Thread Size ivy-Duty U-BolI~ with Hex Nutst--Mechanically Galvanized 3/, 1'/1, I 1'/1, 3 11/4 2V~m 31/I 1V2 2~/~i 3V~ 2 213/I. 43/, 2V~ 3"/, 3 4 3V~ 4'/; 5~/, 4 5 6'/, 5 6'/. 6 ?V, 8~/~ 1,/, ,/,.-18 12.0 11/z ./1,-18 14.0 1,/, i/,,-18 17.0 11/2 e/~,..18 19.0 11/2 "/11-18 21.0 1~/~ ~/, -16 28.0 1~/~ 3/, -16 37.0 1~/~ ~/3 -16 42.0 1~/, 't, -16 ~.0 1~/, ,1, 46 51.o 2 ~/e -16 ~.0 2 ~/~ -16 76.0 · . ~, · . ? ProBe2 EffedveOcuX~e0 25 2O 5 5 CH File ~13053 Beam Cla~ps, Clamps and Clamp Backs for Rigid Metal Conduit or IMC, Jaw Wt. Lbs. " SId. Per 100 Pk~. CI{IJll NIl, Size Opening T~oping Beam Clamps (Insulator Supports) BH-800 1 ~1/1: I/4-20 Ve-16 - .... IH-601 ~ N~. Size A B One-Hole Clamps--Malleable Iron* 22.0 21.5 45.0 83.0 152.0 A 8 C O 2V-, 2V,, its/,, 2F/= 2,,/- 1.-/, 1/z li/I, "/1: :/~l %z 3.6 100 500 ~/4 1%4 1 V: :/1~ :/:z 4.4 1~ ~ 1 13/aS 1 IS/It 7/3Z I/~ 7.0 ~ ~ 1V~ 1~/~2 17/a V4 'h= 12.3 25 1~ 1 V: 1 ~s/:~ 2~/~: s/;: n/H 17.0 25 1 ~ 2Vz 3 3"/= "/~, "/~, 85.0 5 ~ 3 3s/. 3"/~ :V~ e/~ 116.0 5 25 3V: 3V; 4:/: ~/~ ./~. 169.0 2 10 4 4Vz 5~/~ ;/~ '/~. ~.0 2 10 5 5Ve 6s/~ 7/t '/~e 5~.0 1 5 6 5: V,~ 7% 1 ~ V~. 725.0 -- 1 Clamp Backs--Malleable Iron* RebrtoPncatk'x:lexb'Pnce.. 50 100 50 100 26 100 25 50 10 100 10 50 5 50 5 25 .3 25 1 5 -- WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 SPEC SECTION: SC-19 GROUNDING SYSTEMS ENGINEERING DATA SHEET BARE COPPER CONDUCTOR DATE: DECEMBER 1984 r BARE COPPER Uninsulated and Uncoated 22 * 4 Av~ SOLID · 22 AWG - 1000 'MCM STRANDED SCOPE This specification COvers solid and .sofL annealed uninsulated and copper wire, Au~ln Ft. Wodh Houston New Orleans' Son An$OrdO ToE Free STANDARD . · % .;.'...:. - - . , · · ' . · .,., ~.); · . . .... (, · ~ rA ._ ~8' X 10' I 100 2940 .. 31~" X 8' 3 ..50 2960 314," X 10' 3 50 696 870 1024 1280 SECTIONAL THEtlEQRIXINORQIIIAREMADEIIttIt!ITRiitlTitITEt. LTHATitAIIIEEN n r-~TROLYTIAL,LT PLATill WlTH AHEAVY COA11~ 0FCOF~ER. I ]' 'il 512-,477-98,55 214-219-8182. 817-421-3712 713-688-1909 504-464-8800 512..657-0400 800-950.-7933 RE COPPER ONDUCTOR D~CEMBER 1984 : scol ASTM ASTM CON: SoZ/d Soft, CC 10 BARE COPPER Unlnsulated and Uncoated 22 - 4 AWG SOLID · 22 AWG - 1000 MCM STRANDED and uncoaed ire, the folk>wing for Soft, Annealed C_~-'~,-'~e/_ Wfe for Concentric-lay Stra-t~ed Wfre, Uninsulated ;ATIONS and ClrC~Jit grounding in wire Ardde 250 of the Natkxt/ Cc~te (and subject to local JCTION b~m copper per A,ql'M (Sizes 22- IOAWG) bare copper .oer ASTM strmx~ed (da~s B) B-8 (S/z,Tes 8AWG - fO00MCM) b~re copper per ASTM oon,~.oressed ssranded (dass B) OpUorm for c,a~e specification6 with 22 71.0100 20 .. 71.0121 T8 7/.0152. 16 7/,0192 14. 71,0242 12 . 7/~030=5 2. " T" '3/0: ............. 250."' )71.0822 300. :; .... 350.. :'. 37t.0973 400 - i .... 37/.1840 . ..... 5O0 '!" 371,1162' ......... 750 .' '611,1109 8 71.0486 6 11.0612 4 .., 7/.0772 "' ...7/.086z ' - 7h0974 19~;0664: 19/.0745.. CONDUCTOR DATA .025 "' STRANOEO CO~R '(CLASS e) . . _ .030 .046 .058 .073 .09~. .116 ,1~4 .181 ...227. .z54 .285 ..... .324..-, ..... .364 .408 '- ..... .4~ ...... ' ..... ..... 514 370, ,613 ' 460 .663 :. .... 870 - . - .. 710 .... ;972 ........ 810 WiNaft 2 3 5 13 19 31 79 126 201 -- 2 -- 3 30 14 70 51 loo 81 · I~ .. 129 'I50 ,, 175 2O5 ~S' .,. . 3a.-.: 275 ..4n '320 518 .... 772 " 1850- 2316' CONSULT FACTORY FOR ~RNA~VE CONSTRUCTIONS OR MATERIALS A~iCAN INSULATED ~RE CORP0'RA~ON F~men ~, P, O, , P~ RI ~ - 401-~07~ * ~ 71~3~1~ * Toa Fr~ 8~2~2 ~I0'39~d 90:CZ ~6, I 'T !m . Sl0O0 S.500 Sl000 S120 ,$1O00 Sl000 52O0 S120 Rs00 R500/R1000 R,,.r.r.r.r.r.r.r.r~R1000 RS00/R1000 R5O0/R1000 RSO0 s~ 9n~ WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96~01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 SPEC SECTION: SC-18 PART C WIRING DEVICES SWITCHES RECEPTACLES e 2-Pole, 3-WIre Grounding 20A; 125V DUPLEX RECEPTACLES, "HOSPITAL GRADE", BACK AND SIDE WIRED · Heavy duty virtually indestructible nylon face · Copper aJloy one-piece mounting/grounding strap · Units marked "HOSPITAL GRADE" and identified wire · 'GREEN DOT" symbol. · Steel centrai support plate on cover. · Spring steel retention clips on power and grounding contacts. - Salary ground clip provided for fast inslailation. · U,L, verstj~yj to Federal Spec. WC596-F I · Meets NEMA WD1-t983 heavy duty requirements · Corrosion resistant nickel plated contacts and mounttng straps DESCRIPTION CATALOG NO. Brown 83001' · IvOry 8300Z I 5 B/ T-TTZ L.. 'PA T. r_,- ' 83OO DUPLEX RECEPTACLES, DELUXE, BACK AND SIDE WIRED · Heavy duty virtually indestructible nylon face · Safety grOund cl!p prOvided'for fast installation · Totally enclosed molded cover and base · I~ower c~ntacts with retention dips designed for maximum contact retention on plugs · Large 10-32 power contact screws · Back wire clamps spring retained for easier and faster wiring · Designed for back and side wiring--No, 10 wire maximum · Steel centra~ suppor; plate · U.L verified to Federal Spec. WC596-FI · Meets NEMA WD1-1983 heavy duty requirements DESCRIPTION CATALOG NO:' BrOwn L~2tl::] · I~ry 5,38,.~ · Yellow. corrosion resistant, metamine base and covers 5382CR · :::::::::::::::::::::::: Z:":Z: .:,. DUPLEX RECEPTACLES, HEAVY DUTY, BACK AND SIDE WIRED · Heavy duty virtually indestructible nylon face · Safety ground clip provided for fast installation - Back and side wired for faster wiring · Wrap around mounting strap · Totally enclosed molded cover and base DESCRIPTIC~N Brown Ivory On 4" round cover CATALOG NO- 5742 6--~ TAP ..~.,'..,= s-s2 f '% [ 2% T NOTES.' · For adC~lt'lonat product ~eScrlpf/On derails, see l~tes A2. A1 * FOr weather prorecllve cover~ see Doge FT. t ADDITIONAL ORDERING INFORMAl'ION,, For other cOIor~ ~Od Suffix BL for Black, GRY for Gra~ W tot Whi~ RED tot Reel Arrow Hart DIvision, Cooper Industries 3.28 GF8300 {see Page J4) 3.78 A17 gO s wo~j 8l :9 ~6, 8l lrlf 20A; 120-277VAC QUIETTE, TOGGLE & LOCK TYPES BINDING SCREW TYPE, FOR BACK AND SIDE WIRING · Sa(ety ground clip automatically grounds mounting strap · Virtually indestructible LEXAN® lever · Totally enclosed base and cover ,, Accepts #10 AWG wire, back or side wired · I Verified to federal specification WS896E DESCRIPTION Single Pole I Double Pole · Three-Way · ' Four-Way · S~ngle Pole, LOCK TYPE + Double Pole, LOCK TYPE + Three-Way, LOCK TYPE + Four.Way, LOCK TYPE + Key. 1 per sw~Icn 20 Ampere ~dentilicahon: red molded Base. CATALOG NO. Brown'~ Ivory 1222 17sr~1 1223 1224 1223Z 1224Z 1221L 1222L 1223L 1224L 2000 Weereef proof installallen, Use 7420 pli|e lot FS/FD boxes or 7420 and 7349 Irame lot husr~ I;xxes. t NOTES: ' · AC swiftties are not recornmendeo'/or use ell Mister or Ernen~ency Power Syittm& · AC swllcnes can 13e u~ed on H.R a,opl~clUon$ aS pelmilled I~, N.E.G plfll/tl,o//I 430.83 In0~ 430,10g. · H.P. CONVERSION DATA (iAo/tes Io 277VAC $wilcl~el only),' 20 AMP$ 2 H.R 240t~AC t ADDITIONAL ORDERING INFORMATION: For offer co/oil sod rutfix GRY lot G~i,X W for While C 10 f ! 'T ._"Specification Grade GFCI "Feed-Thru" Duplex Receptacles RATING 15A; 125V (NEMA 5-15R) 20At 125V (NEMA 5-20R) ~Pr~-T C DESCRIPTION CATALOG NO. (with will plltl) Brown GF5242' }vory GF5242~ * White GF5242.W Brown GF5342 Ivory GF5342Z Whfte ~--F~;342W IvOry, Master Unit (~ GF2091MZ'-** · Available in bulk pack (without wall plate, 10 per caRon). Specify Catalog No GF5242.X (Brown) or GF5242-XI (Ivory). · ' A Md~tur Unet If~ a GFCI without receptacle oufiels for protection of downstream receptacle8 or equipment. Contain6 Integral LED th,,t Is on when there is power to the downstream circuit. -----1.80 ,- 3.28 3.78 GF5242 WALL PLATES DESCRiPTiON Brown, Smooth Plastic Ivory, Smooth Plastic While, Smooth Plastic Type "430" Stainless Steel Type "302" Stainless Steel CATALOG NO. 1 -Gang 2-Gang (Switch and GFCI Ouplex) 91061-BR:~ · 91672 91061:Z:l: · 91672T 91061W~ · 91672W 97061 97672 93061 93672 Add Suffix -- MH for extra deep plate· Designed for mobile home apphcations. · Virtually Indestrucfibie high Impact resistant thermoplastlc. (:, 91061! WEATHER PROTECTIVE COVERS For use with GFCI "Feed-Thru" Duplex Receptacles, DESCRIPTION CATALOG NO. Cast aluminum lift cover only, fits standard outlet Pox. 4501 Cast aluminum, lift cover, fits standard outlet box, commercial grade 4502 il))Cast aluminum lift cover only, fits FS boxes. 4501FS GF5242:X, Installed with 4501 Weather Prolecllve Coyer J3 Arrow Hart DIvision · Cooper Industries '!1 WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-.01 CITY OF COPPELL, TEXAS SUBMITTAL NO. 9 SPEC SECTIONS: SC-16 PART C WIRE & CABLE 600 VOLT CABLE SHIELDED CABLE .... T ..............T ........"'IT' ....... Rome Cable On-Line Catalog - SPEC 2100 Page 1 of 3 SPEC 2100 January 1, 1991 ROME XHHW-2 Rome-XLP Insulation, 600 Volts APPLICATION: 1. General purpose wiring for lighting and power - residential, commercial, industrial buildings in accordance with National Electric Code, maximum conductor temperature of 90°C in wet or dry locations, for circuits not exceeding 600 volts, for installation in conduit or other recognized raceways. 2. Suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less, such as isolated circuits supplying anesthetizing locations per Article 517-160 of the NEC. 3. Suitable for use as low leakage inductive (loop) vehicle detector wire in accordance with state and municipal requirements. STANDARDS: 1. Listed by Underwriters Laboratories as Type XHHW-2 per UL Standard 44 for Rubber-Insulated Wires and Cables. 2. Conforms to ICEA Pub. No. S-66-524, utilizing Column B thicknesses. 3. Conforms to Federal Secification J-C-30B. CONSTRUCTION: Annealed uncoated copper conductor, Rome-XLP therrnosetting chemically crosslinked polyethylene insulation, surface printed. Size latiou Nom. Ampacity* AWG No. of Thick- Diam. or Strands hess Inches I kcmil Mils 75°C 90°C Net Approx. Wt. Lb./1000Ft. 14 7 30 .14 20a 25a 18 12 7 30 .16 25$ 30a 27 10 7 30 .18 35a 40a 40 Ship- ping Stranded 19 19 28 29 41 43 Copper Conductor Standard Package Length [ 500' spls. 2500' 500' spls. 2500' 500' spls. 25OO' Stock Items t 4/ctn. S NR reel S 4/era. S NR reel S 2/ctn. S NR reel ,S S http://www .romecable .corn/2 100.html 7/22/98 Rome Cable On-Line Catalog - SPEC 2100 Page 2 of 3 8 7 45 .24 50 55 66 67 1000' NS 6 7 45 .28 65 75 96 105 NS 4 7 45 .32 85 95 145 160 NS 2 7 45 .38 115 130 225 245 NS 1 19 55 .44 130 150 290 310 NS NR reel S S S NR reel S S ~ reel S S NR reel S S NRreel SSSS SSS NRreel SSSS SSS NRreel SSSSSSS NRreel SSSSSSSS SSSSSSSS NR reel SSSSSSSS NR reel S 1/0 19 55 .48 150 170 360 380 NS 7./0 19 55 .52 175 195 450 470 NS 3/0 19 55 ' .58 200 225 555 590 NS 4/0 19 55 .63 230 260 700 730 NS 250 37 65 .70 255 290 830 865 NS NR reel S S 300 37 65 .75 285 320 990 1050 NS NR reel S 350 37 65 .80 310 350 1150 1210 NS NR reel 400 37 65 .85 335 380 1310 1370 NS NR reel S S S 500 37 65 .93 380 430 1620 17 10 NS NR reel S 600 61 80 1.04 420 275 1980 2080 NS NR reel S 750 61 80 1.14 475 535 2445 2545 NS NR reel S 1000 61 80 1.29 545 615 3240 3380 - * Ampacity in accordance with NEC for not more than three conductors in raceway at the conductor temperature indicated, in wet or dry locations, 30°C ambient temperature. The over current protection shall not exceed 15 amperes for 14 AWG and 20 amperes for 12 AWG and 30 amperes for 10 AWG copper. NOTES: t Color Code: I black, 2 white, 3 red, 4 blue, 5 green, 6 yellow, 7 orange, 8 brown. 2 On non-stocking items, contact Rome Cable for minimum acceptable manufacturing quantities. Information on this page subject to change without notice. Specification ROME XHHW-2 Rome-XLP Insulation, 600 Volts 1. SCOPE 1.1 This specification describes single conductor Rome XI-12HW-2, a general purpose building wire insulated with crosslinked polyethylene (XLPE) intended for lighting and power circuits at 600 volts or less, in residential, commercial and industrial buildings. The wire may be operated at 90&3176C maximum continuous conductor temperature in wet or dry locations and is listed by Underwriters Laboratories for use in accordance with Article 3 10 of the National Electrical Code. 2. APPLICABLE SPECIFICATIONS 2.1 The following specifications form a part of this specification to the extent specified herein: 2.1.1 Underwriters Laboratories Standard 44 for Rubber-Insulated Wires and Cables. 2.1.2 ICEA Pub. No. S-66-524, NEMA Pub. No. WC7 for http://www.romecable.corn/2100.html 7/22/98 Rome Cable On-Line Catalog - SPEC 2100 Page 3 of 3 Crosslinked-Polyethylene-Insulated Wire and Cable. 2.1.3 Federal Specification J-C-30B. 3. CONDUCTORS 3.], Conductors shall be Class B stranded, annealed uncoated copper per UL Standard 44. 4. SEPARATOR 4.1 A suitable separator over the conductor may be used at the option of the manufacturer. 5. INSULATION 5.1 Each conductor shall be insulated with Rome-XLP, a crosslinked polyethylene complying with the physical and electrical requirements of UL Standard 44 for Type XHHW-2o 5.2The average thickness of insulation, for a given conductor size, shall be as specified in UL Standard 44 for Type XHHW-2. The minimum thickness at any point shall be not less than 90% of the specified average thickness. The insulation shall be applied tightly to the conductor and shall be free-stripping. 6. IDENTIFICATION 6.1 The wire shall be identified by surface marking indicating manufacturer' s · identification, conductor size and metal, voltage rating, UL Symbol, and type designation. 7. TESTS 7.1 Wire shall be tested in accordance with the requirements of UL Standard 44 for Type XH2HW-2~ 8. LABELS 8.1 The wire shall bear the Underwriters Laboratories Label for Type XHHW-2. HOME PROFILE SALES CATALOG MAPJ(ETS SERVICES htrp://www.romecable.com/2100.html 7/22/98 aN; II IUMENTATION CABLES OKOSEAL TYPE P-OS POWER-LIMITED Type PLTC Cable/3OOV Rated 105°C Construction: Stranded copper conductors, Okoseal Insulation, color coded. twis(ed into groups of pairs or triads, hum=tic prinl roup identification, multiple roups assembled with communication wire and PlUme and moisture resistant ~illers where required. aluminum/synthetic polymer shield and coated stranded copper drain wire, rip cord, Okoseal jackaL Application: For use on Class 2 or 3 Power-Limited circuits where shielding against exlernal intederence is required, but inlederence I~elween groups is not required; indoors or outsdoors. in cable trays. in raceways. supported by a messenger wire; in Class I. Division 2 or Class II. Division 2 hazardous locations; suitable for direct burial. Catalog Conductor SIze Number Insulation Jacket Apprmc Number AWG (Strands) of Pairs Thicknan-mils Thlckneu-mlls O.D.-Inchee 264-10-2204 20(7X) 4 15 40 .42 264 - 10-2208 20(7X) 8 15 50 .49 264-10-2212 20(7X) 12 15 50 .58 2'~4-10-2224 20(7X) 24 ..... 15 60 .76 264-10-2236 20(7X) 36 15 60 .87 264-10-4404 16(7X} 4 15 50 .51 264-10-4408 16(7X) 8 "' 15 60 ,64 264-10-4412 16(7X) 12 15 60 .76 264-10-4424 16(7X) 24 15 70 .99 OKOSEAL TYPE SP-OS POWER-LIMITED Type PLTC Cable/3OOV Rated 105°C UL Construction: Stranded copper conductors, Okoseal insulation, color coded. twisted into one pair or triad, or groups of pairs or triads, humeric print group identification, aluminum/synthetic polymer shield and coated stranded copper drain wire over each group with 100% isolation between group shields, multi~e roups assembled with communication wire and flame and moisture rNistant ~illers, where recluired, aluminum/synthetic polymer shteld and coated Itranded copper drain w;re overall, rip cord, Okoseal jacket. Application: For use on Class 2 or 3 Power-Limiled circuits where low level signals require shielding both from adJacenl groups as well as external sources; indoors or outdoors. in cable trays, in raceways, supported by a messenger wire; in Class I, Division 2 or Class II, Division 2 hazardous locations; suitable for direct burial, SIngle Pair/Triad Cables (P-OS) and Multi-Pair Cables (SP-O8) Catalog Conductor 81ze Number Number Insulation Jacket Approx, Number AWG (Strands) of Pairs of Triad= Thlckneu-mll= Thickness-mils O,D,-Inchel 264-10-3301 18(7X) 1 15 35 24 264-10-4401 16(7x) 1 15 35 264-15-4401 16(7x) 1 15 35 28 261-10-220zl 20(7X) 4 f 5 - 50 261 - 10-2208 20(7X} 8 15 50 261 - 10 -2212 20(7x) 12 15 60 .68 261 - 10-2224 20(7X) 24 15 70 .94 261 -10-2236 20(7X) 36 15. 70 1.05 261 - 10-2250 20(7X) 50 15 80 122 261-15-2204 20(7X) 4 15 50 .49 26 t - 15 -2208 20(7X) 8 15 50 .64 261-15-2212 20(7X) 12 15 60 .77 261-15-2224 20(7X) 24 15 70 1.05 261 - 10-3304 18(7x) 4 15 50 .49 261 - 10-3308 18(7X) 8 15 60 .65 261-10-3312 18(7X) 12 15 60 .76 261 - 10-3324 18(7X) 24 15 70 1.05 261-10-3336 18(7X) 36 15 70 1.1 7 ~61-10-3350 18(7X) 50 15 80 1.40 261 - 10-4402 16(7x) 2 15 50 .48 261 - 10-4404 16(7x) 4 15 50 .54 26 t - 10-4408 16(7x) 8 15 60 .72 261 - I 0-4412 16(7X) 12 15 . 60 .86 261 - 10-4424 16(7X) 24 15 70 1 ,I 8 ~6 t - t 0-4436 16(7x) 36 15 80 1 ,~5 261 - 15-4404 16(7X) 4 15 50 .60 261 - 15-4408 16(7X) 8 15 60 ,80 26'1 - t 5-4412 16(7X) 12 15 70 .g9 WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL~ TEXAS SUBMI'I'FAL NO, 9 SPEC SECTION: SC-17; AND SHEET 12 OF 17 PANEL BOARDS ITEM MANUFACTURER CATALOG NUMBER DESCRIPTION 1 CUTLER-HAMMER DH324NDK DISCONNECT 2 GOULD SHAWMUT TR150R FUSE 3 CUTLER-HAMMER PANEL A POWERLINE 1A 4 CUTLER-HAMMER PANEL B CH TYPE LOADCENTER 5 CUTLER-HAMMER CN35GG2CB CONTACTOR 6 CROUSE HINDS D2S20 PHOTOCELL 1/20/89 Supersedes Page 9 of 7/86 Issue CUTLER-HAMMER~ SAFETY SWITCHES 200 Ampere Heavy Duty~ K-Series Design NEMA 1 ENCLOSURE HORSEPOWER RATING -- Standard: with NEC fuses. Maximum: with Time Delay fusing or non-fused switch. (Std.- Max.) HP Ac Volts Dc Volts Phase T_ype 240 480 600 250 600 1 2-3 Pole 15-15 25-50 30-50 40-40 50-50 O 2 4 Pole 30-50 25-50 30-50 40-40 --- 3 3-4 Pole 25-60 ~) 50-125 60-150 40-40 --- 600 V dc rating 0nly with tw0-p01e switches. Tw0-pole with neutral has these ratings on Grounded B-Phase system. LUG CAPACITY -- Wire Size -- 60°C or 75°C Crimp Lug Pad Numbers Standard Lug AL/CU #6-300MCM Wire Borndy T & B Size Copper Aluminum Aluminum 1/0 YA25-2N YA25A7 --- 2/0 YA26-2N YA26A3 60238 3/0 YA27-2N YA27A3 60244 4/0 YA28-2N YA28A5 60250 250MCM YA29-2N YA29A3 60256 DESIGN CHARACTERISTICS · 7 TECHNICAL | NFORMATION PUBLICATION DH-K Rating -- 200 amperes -- continuous line current notto exceed 80% of fuse rating employed in other than motor circuits. · Configuration -- Two-, three- & four-pole; fusible or non-fusible switches. · Service Entrance -- Suitable as service entrance equipment. · Mechanism -- Double break visible rotary blades -- quick make/quick break operation. · Line Shield -- Shield with probe holes, separate from switch structure. · Molded Bases -- Glass based polyester. · Fuse Features -- 250V or 600V clips and spacing. Backup springs on fuse clips. Built-in fuse pullers. · Current Carrying Parts -- All are plated copper. · Lugs -- Front removable, standard mechanical lugs and lay-in ground lug. · Standards -- Meets Federal Specification WS865C; UL 98 for switches; NEC wire bending space, Table 373-6(b); NEMA Standard KS1. Meets major automotive specifications. UL listed, File No. 5239. · Shod Circuit Rating -- 10,000 RMS symmetrical amperes for non-fused switches and switches with standard Class H fuse clips. 200,000 RMS sym- metrical amperes with Class R, T or J fuse clips. · Locking -- Door hasps may be locked, handle can be locked OFF with up to three 3/8" shank locks. · Door Interlocks -- Switch cannot be turned ON with door open, door cannot be opened by unauthor- ized personnel with switch ON. · Nameplate -- High visibility, embossed metal name- plates. · Tangential Knockouts -- NEMA I & 3R. · Enclosures -- NEMA 1, 3R, 4X stainless steel and NEMA 12/3R. The 12/3R enclosure is made suit- able for type 3R application by removing a screw to provide a drain hole. · Renewal Pads -- Handle, switch operating mechan- ism, line shield, switch base and fuse base are all separately replaceable. OPTIONAL FEATURES · Neutral -- Field installable neutral kit. · Class R Fuse Clip Kit · Class T Fuse Kit · Class J fusing -- move fuse clips for J spacing. · Interlock -- 1 NO/1 NC or 2 NO/2 NC kits available. · Ground Lug Ki~ · Blown Fuse Indicator (BFI) The nstallation and use of Cutler-Hammer products shou d be in accordance with the provisions ol the U.S. National Electrical Code and/or other local codes or industry I slandards lhal are pedinenl to the padicular end use. Installation or use not in accordance with Ihese codes and standards cou d be hazardous to personnel and/or equipment. E;T.N Printed m U.S.A. GG 7 8 TECHNICAL ~ NFORMATION PUBLICATION DH-K CUTLER-HAMMER® SAFETY SWITCHES 200 Ampere Heavy Duty, K-Series Design .~ROXIMATE DIMENSIONS -- All knockouts are tangential except as noted. + ~~M~O2. 2-I/2, 3 M - - P & BOTTO 7/a NEMA I -- 2 and 3 Pole ' Fusible and Non-Fusible Switches ToP o 1-1/2, 2, 2-12 I 7/8 }- 16-----~ h-:t..3/4 ~ 1~-1/2 = 2~~~s NEMA I Enclosure: 0.060" cold rolled steel - :~,:~ .,~-, I .... ASA 49 medium gray .baked enamel finish ..... ""~';'E~ 8~ 3 mounting screws, 5/16" max. dia. 30- -7/8 31 t 2 K0'S ' CO CENTRIO , · N ,2, 2-112 12 1/8 2-518 1/20/89 1-1/2, 2, 2-1/2 .,~')k,, r,~__._._.16 ~l 3/4 .-,-----11-1/4----~ 318 + ¢ -: 27 ~ 30-5/8 31 ~ 2 KO'S CONCENTRIC 1-1/2, 2, 2-1~ . 1-718 12 6 4 K0'S /-BOTH SIDES 718~ 1-112, 2, 2-1/2 NEMA 3R -- 2 and 3 Pole Fusible and Non-Fusible Switches NEMA 3R Enclosure: 0.064" zinc coated steel ASA 49 medium gray baked enamel finish Side hinged with drip shield 3 mounting screws, 5/16" max. dia. 4 MTG. SCREWS 1/2" MAX. DIA. 16 ----.~;p 3/4 E'-'[.N ~11-1/2 ~;__ 34-3/8 NEMA 4X & 12/3R -- 2, 3 and 4 Pole Fusible and Non-Fusible Switches NEMA 4X Enclosure: 0,060" Type 304 stainless steel, brush finished. NEMA 12/3R Enclosure: 0.064" zinc coated steel ASA 49 medium gray baked enamel finish NEMA 3R requirements are met when drain hole screw is removed. L6'1/2""" See note on installation and use of product at bottom of page 7. Printed in U.S.A. GG TRI-ON~C' TR&TRS '~ GOULD SHAWMUT TIME DELAY / CLASS RK5 ,7 GO THE INDUSTRY'S MOST POPULAR FUSE FOR MOTOR CIRCUIT PROTECTION. Tri-onic® TR and TRS current limiting time delay fuses are engineered for overcurrent protection of motors and transformers, service entrance equip- ment, feeder and branch circuits. Tri-onic's proven time delay characteristic safely handles harmless starting currents and inrush currents associated with today's motors and transformers. Features/Benefits > Time delay for motor start-ups and transformer inrush currents without nuisance opening ~ Current limiting for low peak let-thru current :,.- Rejection-style design prevents replacement errors (when used with recommended fuse blocks) ~-. Easy-to-read imprint label for quick recognition and replacement ~. Metal-embossed date and catalog number for traceability and lasting identification Fiberglass body provides dimensional stability in harsh industrial settings ;- Brass end-caps (blade-style) for cooler o~eration and superior performance '>~ High-grade silica filler ensures Iast arc quenching and high current limitation HIGHLIGHTS: · Time Delay · Current Limiting · AC & DC Rated APPLICATIONS: Motor Circuits Ratings Approvals Mains ~ TR ~ UL Listed to AC: 1/10 to 600A Standard 248-12 Feeders 250VAC, 200k, A I.R. ~ CSA Certified to Branch Circuits DC: 1/10 to 2 8/10A Standard C22.2 & 35 to 400A, No. 248.12 ::-. Transformers 250VDC. 20kA I.R.; ,,~- Service Entrance 3 to 30A & 450 to 600A, · DC Listed to Equipment 160VDC, 20kA I.R. UL Standard 198L · ., General-purpose ~-- TRS AC: 1/10 to 600A Protection 600VAC, 200kA I.R. DC: 1/10 to 12A, 600VDC, 20kA I.R.; 70 to 600A, 600VDC, 100kA I.R.; 15 to 60A, 300VDC, 20kA I.R. PF2 TRI-ONIC ~ TIME DELAY / CLASS RK5 FUSES Fuse Amgere Ratings, CataJog r, tumbers Ampere Catalog Number Ampere Catalog Number Ampere Rating 250V 600V Rating 250V 600V Rating 1/10 TR1/IOR TRS1/IOR 3-1/2 TR3-1/2R TRS3-1/2R 50 15/1 O0 TR15/100R TRS15/100R 4 TR4R TRS4R 60 2/10 TR2/IOR TRS2/IOR 4~1/2 TR4-1/2R TRS4-1/2R 70 3/10 TR3/1 OR TRS3/1 OR 5 TR5R TRS5R 75 4/10 TR4/1 OR TRS4/1 OR 5-6/10 TR5-6/1 OR TRS5-6/1 OR 80 1/2 TR1/2R TRS1/2R 6 TR6R TRS6R 90 6/10 TR6/IOR TRS6/IOR 6~1/4 TR6-1/4R TRS6-1/4R 100 6/10 TRa/1 OR TRS8/1 OR 7 TR7R TRS7R 110 1 TR1 R TRS1 R 8 TR8R TRSaR 125 1-1/8 TRI-1/aR TRS1-1/8R 9 TR9R TRSgR 150 1-1/4 TRI-1/4R TRSI-1/4R 10 TRIOR TRSIOR 175 1-4/10 TR 1-4/1 OR TRS1-4/1 OR 12 TR 12R TRS12R 200 1-6/10 TR1-6/1 OR TRS1-6/1 OR 15 TR15R TRS15R 225 1-6/10 TR1-8/IOR TRS1-8/IOR 17-1/2 TR17-1/2R TRS17-1/2R 250 2 TR2R TRS2R 20 TR20R TRS20R 300 2-1/4 ,,TR2-1/4R TRS2-1/4R 25 TR25R ' TRS25R 350 2-1/2 TR2-1/2R TRS2-1/2R 30 TR30R TRS30R 400 2-8/10 TR2-6/1 OR TRS2-8/1 OR 35 TR35R TRS35R 450 3 TR3R TRS3R 40 TR40R TRS40R 500 3-2/10 TR3-2/1 OR TRS3-2./1 OR 45 TR45R TRS45R 600 O-60A GOULD SHAWMUT TR & TRS Catalog Number 250V 600V TR50R TRS50R TR60R TRS60R TR70R TRS70R TR75R TRS75R TRaOR TRS80R TRgOR TRS90R TRIOOR TRSIOOR TR110R TRS110R 125R TRS125R TRS150R TRS175R TR2OOR TRS2OOR TR225R TRS225R TR250R TRS250R TR3OOR TRS3OOR TR350R TRS350R TR4OOR TRS4OOR TR450R TRS450R TR5OOR TRS5OOR TR6OOR TRS6OOR A 61-6OOA RATING 0-30 2 51 31-60 3 76 61-100 5-7/8 149 101-200 7-1/8 181 201-400 8-5/8 219 401-600 10-3/8 264 600V-TRS FUSES 0-30 5 127 31-60 5-1/2 139 A B C D I mm In. I mm In, lmm In. 9/16 14 - 13/16 21 - 1-1/16 27 1/8 3 3/4 19 1-9/16 40 3/16 5 1-1/8 28 2-1/16 53 1/4 6 1-5/8 41 2-9/16 66 1/4 6 2 51 13/16 21 1-1/16 27 '~F 61-100 7-7/8 200 1-6/16 34 101-2OO 9-5/8 244 1-13/16 46 201.400 11-5/8 295 2-9/16 66 401-600 13-3/8 340 3-1/8 80 1 1-3/8 1-7/8 2-1/4 E Recommended Fuse Blocks With In. I mm BDX Connectors For Tri-onic' Class RK5 Fuses 1/8 3 3/4 19 1 3/16 5 1-1/8 28 1-3/8 1/4 6 1-5/8 41 1-7/8 1/4 6 2 51 2-1/4 Fuse Catalog Number 25 Ampere 250V 600V 35 RatJng 1 Pole 3 pole I pole 3 pole 48 O-3O 20306R 20308R 60306R 60308R 57 31-60 20606R 20608R 60606R 60608R 61-100 21036R 21038R 61036R 61038R 101-200 22001R 22003R 62001R 62003R 201-400 24001R 24003R 64001R 64003R 25 401-600 2631R 2633R 6631R 6633R 35 48 A variety of pole configurations and termination provisions is available. 57 9 13 '15 17 19 21 23 25 27 29 33 35 37 39 41 43 45 47 49 51 53 Main Lugs 225A 1 .....~QBHW3015H 5-~ 7 ':_-~_,---QBHWi020 '..~.QBHW2020H "~---QBHW 1020 .-,~BHW2020H ':-~BHW~020 )---~QBHW2020H ..~ : T'~BHW 1020 7.~0BHW 1020 -.~BHW2020H .... ~QBHW2050H ·-~- qBHW2020H--- 38 · : ~BHW2020H ~- '40 ..: 2. ' ~ ~ ~'~ o~F =f 42 ........ ~lan~ ....... ...... b~E blank ........ 6~ Blank .... 48 ........ blank '~"'5o ...... blOC ......... 6~k .... 5 · QBHW3015H ~=-2 ..... 5'~BHW ~ 020:5.'_ :8 i QBHW2020H---: 10 .~--;12 7QBHW2020H---, 14 .:.~"~. t6 ' 'i~'~HW ~ 020!:2 18 QBHW3015H .... 20 :....-- 22 "' 24 QBHW2020H--- 26 -' .....28 QBHW1015 7~. 30 QBHW2020H_..-T'' 32 Modifications Qty Catalog # Description General Information Service Voltage: Bus Bar: Neutral: S.C. Rating: Enclosure: Catalog # Type: Location: Trip: Terminal: Qty/Range: Box Catalog#: Box Height: Width: Depth: Ground Bar: 240/120 3Ph 4W B HiLeg 225A-SnCu 225A-SnCu. 100% 22k A.I.C. Fully-Rated N EMA 12 Main: KL23TMS MLO Top N/A Mechanical (AI) (I) #6-300 MCM (CQ/AI) VWPB2060 G u tte r 60"/1524.0mm Top: 20"/508.0mm Bottom: 5.75"/146.1mm Left: Right: Bolted-SnCu Outgoing: (None) NEC Lighting & Appliance, UL CTL Standard Panel Plant Information Bus Assbly: 1 C96627G02 Neu tra I: 1 C96649G04 Grnd Bar: 5158C05G02 Bus Cut: Branch Devices Qty Poles Trip Frame 1 I 15 QBHW I 0 I . 20 QBHW 3 3 15 QBHWH I 0 2 20 QBHWH I 2 50 QBHWH Amps 100 100 100 100 100 5.5"/139.7mm 5.5"/139.7mm 6.0"/152.4mm 6.0"/152.4mm 1 C96876H49 kAIC 22 22 22 22 22 Notes Prepared By Date Version : Summit Electric Supply 05129198 2.14 , Approved By Date Size A Cutler-Hammer Sumter, SC Neg-AIt Number D25405299801-0000 Job Name Wagonwheel DeSignation Panel A Product Name Pow-R-Linel a G.O. Number Item Drawing Type Customer Appr. : Sheet I of 1 Summit Electric Supply 500 North Beach St Fort Worth, Tx Neg# D25405299801 Alt# 0000 Job Name: Wagonwheel Customer Bill of Material 05/29/98 11:39:34 2 2 TYPE CH MLO LOADCTR 1PH/2-SCKT/40A- Catalog # CH8LI25R 125A TYPE CH MAIN LUG OUTDOORN3R LOADCTR 8 CIRCUIT CH PLUG-ON CIR BKR 1P/10A-70A/10K Catalog # CH 120 Type CH Breaker 20A/I Pole 120/240V 10K CH GRND FAULT BKR 30MA 1P/10K Catalog # CHI ISEPD Type CH 30mA GFI Breaker 15A/1 Pole 120/240V 10K Pow-R-Linela 54 Circuit, 225A, Fully Rated, 2401120 3Ph 4W B HiLegTin-plated Bus. 22k AIC, 225A Main Lugs Only I 1 10 10 1 3 1 1 I I 225A Main Lugs Only 15A 1 Pole [QBHW] 20A 1 Pole [QBHW] 20A 2 Pole [QBHW-H] 50A 2 Pole [QBHW-H] 15A 3 Pole [QBHW-H] Copper Bus[Tin-Plated] Neutral: (Neutral Not Sized) Bolted Ground Bar Nema 12 enclosure: VWPB2060 Special Configuration Notes: Designations: Panel A 2 WHEN ORDERING SPECIFY · Catalog Number plus suffix letter from Magnet Coil Selection table. DESCRIPTION Type CN35 magnetically held Lighting Contactors are designed to handle the switching of tungsten (incandescent filament) or ballast (fluorescent and mercury arc) lamp loads as well as other non-motor (resistlye) loads. LOADS Ballast Lamps = Fluorescent, Mercury Vapor, Sodium Vapor, Quartz -- 600 Volt Maximum. Filament Lamps = Incandescent, Infrared, Sodium Iodine, Heating -- 480 Volt Maximum. Resistance Heating = Radiant and convection heating, furnaces and ovens. COVER CONTROL -- See listing Page A-8. Start-Stop and Hand-Off-Auto only. Lighting Electrically,HeM 20 Ampere 60 Ampere Cat. No. CN35BN3AB Cat. No. CN35GN5AB AUXILIARY CONTACTS CN35 Lighting Contactors include a NO maintaining auxiliary contact mounted on right hand side (on 10 Ampere, 2 and 3 pole devices, auxiliary contact occupies 4th power pole position -- no increase in width). Enclosed devices include a NO auxiliary contact only on the right hand contactor. The 10 through 60 ampere devices will accept additional auxiliary contacts on the top and/or sides -- 100 through 300 ampere sizes will accept side mounted auxiliaries only. See Auxiliary Contact listing on Pages A-77 - A-78. CN35 AC LIGHTING CONTACTORS -- ELECTRICALLY HELD OPEN TYPE NEMA 1 ENCLOSE0 NEMA 3R ENCLOSED NEMA 12 ENCLOSED MAXIMUM Number Frame AMPERE of Catalog Catalog Catalog RATING O Poles Size Catalog Price Price Price Price Number 2 CN35AN2_B $ 120. CN35AG2_B $ 132. CN35AR2_B $ 244. CN35AD2_B $ 244. 10 3 45 mm AN3_B 138. AG3_B 150. AR3_B 270. AD3_B 270. 4 AN4_B 186. AG4_B 198. AR4_B 330. AD4_B 330. 2 CN35BN2_B 156. CN35BG2_B 168. CN35BR2_B 280. CN35B02_B 280. 3 BN3_B 174. BG3_B 186. 8R3_B 306. BD3_B 306. BN4_B 242. BG4_B 260. BR4 B 386. BO4_B 386. 20 4 45 mm - 6 BN6_B 314. BG6_B 374. BR6_B 430. BO6_B 430. 9 BNg_B 460. BG9_B 526. BRg_B 620. BDg_B 620. 12 BN12_B 584. BG12_B 644. BR12_B 720. BO12_B 720. 2 CN35DN2_B 186. CN35DG2_B 198. CN35DR2_B 272. CN35DD2_B 272. 3 DN3_B 204. DG3_B 216. DR3_B 290. DD3_B 290. 4 DN4_B 254. D64_8 266. DR4_B 338. DD4_B 338. 30 5 45 mm DN5_B 330. DG5_B 350. DR5_B 422. DD5_B 422. 6 DN6_B 388. DG6_B 408. DR6_B 504. DD6_B 504. 9 DN9_B 534. DGg_B., 594. DRg_B 756. DDg_B 756. 12 DN12_B 732. DG12_B 792. DR12_B 1008. DD12_B 1008. 2 CN35GN2_B 348. ~ 408. CN35GR2_B 542. CN35GD2_B 542. 3 GN3_B 372. 432. GR3_B 566. GD3_B 566. 60 4 e 65 mm GN4_B 480. GG4_B 540. GR4_B 674. GD4_B 674. 5 e .~.: ....GN5_B '~. 720. · ·-: GG5_B 780. GR5_B 902. GDS_B 902. 2 90 mm CN35KN2_.. ~ .:' 522. CN35KG2_"'- - 672. CN35KR2._ 830. CN35KD2_ 830. 1 O0 e 3 ,' '. KN3.:~;'~-,r 600. : KG3_~: 720. KR3_ . ." 878 KD3_ 878. 2 180 mm CN35NN2j;~! ;- 1332. CN35NG2_, ,:~' ' 1564. CN35NR2_: 2102. CN35ND2_ . 2102. 200 ~) 3 '.=---.- NN3._%;~.j!L 1440. : :,- NG3_":"':' 1692. NR3_. :: 2210. ND3_ 2210. CN35SN2::j;.:.-::,: 2886. CN35S62..:' ' 3348. CN35SR2_. 4251. CN35SD2_- 4251. 300 2 180 mm - 3 ' 'SN3_--~' ;' 3138. '- $63_' ".' 3600. SR3_ - 4572. SD3_ 4572. The listed ampere ratings are based on a maximum load voltage of 480V for tungsten lamp applications and 600V for ballast or memury vapor type applications. Additional power poles mounted on side(s) of contactor, Underscore (_) indicates missing Code Letter for Magnet Coil -- see Magnet Coil Selection table next page. For 4.--12 pole contactors, see A202 contactors on Page Y-T/. TECHNICAL DATA, Pages A-19 - A-21 SPECIAL MODIFICATIONS, Pages C-52 - C-53 DISCOUNT SCHEDULE: Open Type 1CO-l, Enclosed Devices 1CD-1C July 1995 DIMENSIONS, Next Page E:T.N A-13 Electrically Held ~~~-MAGNET COIL SELECTION Add code letter suffix of selected coil to listed catalog number, Example: For a 10 Ampere Open Type contac- H H tor with a 120V, 60 Hz magnet coil, order CN35AN2AB. For DC MAGNET COILS, see ACCESSORIES, Page A-83, NEMA RATED AC; C;(JIV IAC;[O R5 Lighting Code Coil Volts and Hertz Suffix 120/60or110/50 A 240/60 or 220/50 ~ 480//60 or 440/50 600/60 or 550/50 208/60 E 277/60 H' 208-240/60 O J 240/50 K 380-415/50 L 550/50 N 24/60, 24/50 T 24/50 U 32/50 V 48/60 W 48/50 Y 0 For 10, 20 and 30 ampere sizes only, 20 Ampere Cat. No. CN35BG9AB APPROXIMATE DIMENSIONS AND SHIPPING WEIGHTS Rating No. J Dimensions in Inches [mini I Ship. Ampere :fes Wide High Mounting Wt Lb~' PI A · 10 2 - 4 2.00 :~i~ 20-30 2-3 2.00: 20 - 30 4 - 6 4.20 ] 20-309 60 2 - 3 2.56 60 2!3 3.46 60 5 4.36 '111] 10 3,54 90] 0 200 2-3 7.05 300 2-3 7.05 OPEN TYPE 4.3silll .2 891 &:::[::'4...251 2.9 . 38 ~ ......5.8 5.05 ' 28' 7.17 182' 5.94 '15f 3.0 6.63 '168 --- : ~ 9 13.12 333, 7.78 198: 6.0 12.5 406: ...... 23 NEMA 1 ENCLOSED 5.12 130 4,50 114~ 8.00 203 ...... 5 ,.00 ...... 6.77 10.0 [2~ 1~: ...... 16.8 13.27 '337 6.21 '158' 6.~ 152' 10.75 273 ...... 6.85 13,30 '338 6,~ '172 10.0 254' 10,75 273 ...... 14,55 21.6 '~ 9.1 '227' 10,5 '267 19.9 506' - ..... 35 31.8' 9.3 '236' 10.5 267 19.9 '506 ...... 47 45.62 1159] 11.~ 280: 15.0 381. 30.~ '7~. - ..... 113 NEMA 3R & 12 ENCLOSED '302 5.25 [133] 10.88 276' - ..... 12.9 18,00 7.31 186' 430' 18.8 '457 ...... 7.5 [191 16.~ '548 8,69 22f 10.5 26 19.88 505 39 21.56 ...... 31.75 9.25 235 30.13 765 ...... 110 45.63 ] 11.0 279 43.88 1115] ...... 168 10 2-4 5.63 143 10.17 258 20-30 4-6 : 10.17 20-30 9-12 12.591312] 13.30 60 2 - 3 7.63 [194] 60 4 - 5 12.59 [312] 100 2-3 14.9 379 300 2-3 10-60 2-6 8.75'[222] 20-30 9 - 12 10.88 276 100 2~3 14.88 3;~8 300 2 - 3 NEMA 1 Enclosed 10-60 Ampere Sizes B E r-s ~C---~ NEMA 1 Enclosed 100 - 300 Ampere Sizes, NEMA 3R & 12 Enclosed 10-300 Ampere Sizes MTG. HOLES FOR elO-32 ~..,REWS I''''A I --e 'Fc I A ~' 'D '"~' '~' D #10- 32 SCREWS Open Type Open Type 20 - 30 Ampere Sizes, 4 - 6 Poles Center mounting slot at bottom on 10 through 30 ampere sizes only.. See "AUXILIARY CONTACTS" on previous page for type and location of auxiliary contacts supplied. #10 - 32 SCREWS open Type A 12 Poles 20 - 30 rapere Sizes, 9 - A-14 TECHNICAL DATA, Pages A-19 - A-21 SPECIAL MODIFICATIONS, Pages C-52 - C-53 July 1995 3L-38 V2PC Photocell Dimensions Ordering Information CI. I, Div. 2, Groups A,B,C,D Dimensions: Cat. # EV21H a b 5.00 4.25 V2PC 'T ® EV21H c d e 2,60 4.54 5.25 4114' D2S 41/4' Ordering Information Photocell for field installation* Catalog # Voltage Range V2PC20 120V, 50/60 Hz V2PC22 220/240V, 50/60 Hz V2PC27 277V, 50/60 Hz * Must be factory installed in Canada -- consult CrOuse-HindS. Photocell in DS cover for use with FS/FD box Voltage Range 120V. 50/60 Hz 220/240V, 50/60 Hz D2S27 277V, 50/60 Hz Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D; Class Ii, Division 1, Groups E, F, and G; and Class III locations Catalog # Voltage Range E'V21H20 120V, 50/60 Hz E'V21H22 220/240V, 50/60 Hz EV21H27 277V, 50/60 Hz Janua~1996 Copyright' 1996 Cooper Industries. Inc. WAGON WHEEL RANCH 2.0 MG ELEVATED STORAGE TANK PROJECT NO. WA-96-01 CITY OF COPPELL~ TEXAS SUBMITFAL NO. 9 SPEC SECTION: SHEET 12 OF 17 INFRARED QUARTZ HEATER 7-MTM-8 - S U N - M I T E ® "l Overhead Heaters for Outdoor Snow E Ice Cont~l, and Indoor Total Area Heating mid !ndoor/Ouldoor Spot Heating Made In U .S .A. !a;[d~.llfal~l Mount Heaters Horizontally MuI-T-Mount idearod Quartz Idmp Heatm Fostoda's MuI-T-Mount~ high-density. Quartz Lamp Infrared Heaters provide instantaneous radiant heat in areas where a forced air heater would require more time and energy to heat. Bectric Infrared hem people and objects directly, and re-radiates in the form of convection heal Objects within the reflector/heat pattern such as tools, work benches and floor= are quickly warmed. Three lamp MuI-T-Mount heater~ produce 50% higher wattage dermities for a given reflector pattern, adding flexibility in the design of heating eyetams. Three ale- merit heaters provide for a balanced three phase load when wiring into a three phase system. Use for. total area heating. ~ or zone heating and anew & ice control. Featurea: * UL Listed for totally exposed [outdoor3 enow and ice control and Gndoor) comfort heating applications · Heat output CTotal Wattage): 3,200 W 1222 Series3 7,300 W C462 SeriesJ 4,80t3 W C223 8edes) 10.950 W (463 Series) 5,000 W C34:Z Series) · Separate reflectors for maximum pattern control · 50% higher watt densitie~ for 3-element unite · Stainless steel models have non-corrosive housing, hardware and bracket$; no ferrous metals used in the unit. Durable in harsh atmospheres & outdoor lpplications · Gold anodized aluminum reflectors & end c~ps · High temperature lead wire~ , Single or three phase wlrlng (Consult Factory} · Knockout~ for condu|t on both ends centered in top wiring channel · Optional recessed mounting improves the appearance of drop ceiling applicaeons · Optional wire guards for all sizes · Optional Ruby Red Vycor~ sleeves filter out bright light · UL Listed fo~ recessing appl;cat;ons · Clear Quartz Lamps with pratelain endl included with all fixtures 3-Eiernent MuI-T-Mount Series STAINLESS STEEL construction 2-E~me~ MuI-T-Mm ~nlm ~ w Iminized ~el with a ~d b~ reel ,... ~... . . ;.. ,.'~ < .; ,, !., .:.::: .:.:.::.~ :'.., .:~ .-~ Optional racersing frame (Space on page 3~ j----- I FOSTORIA INDUSTRIES. INC. General PFoducts Divi~o~ 1200 it Min $L F0storit OH 4483043986 (419} 435-9291 FAX: (419} 435-0842 I Mounting for Mul-T-Mount Heater Arty coffibuatible surface (excludes people) wi~In the infrared pattern, should be at least 62 inches awmy from the heater. For surface mounting, fixtupes ere r~luired to be 3 inches from the ceiling, 24 ;nches from s vertical surface and can be ;nste!led end to end uslng a-minimum of 96 inch clearance from the floor. Clearances may be mdu~,,ed to any non combustible surfaces, In all mount- ing configurat;ons, the heater must be mounted 8 m;ni- mum of 721nches from lhl fioor. Heaters may be mounlad horizontally ldir,cted down} or vertically (d;rected away from a weld using Fcatorta vertZcal-bum quartz Ismp,~, Mu!-T-Mount Dimensions ,J 23-1/2" :Z4" t5' 32-1/2" 33" 15" 482 45-I/2" 46" 15" 223 23-1/2" 24" 21-1/2' 463 45-1/2' 46" 2f-1/2" Optional lie, ~,~;,q Frames MuI-T-Mount fixtures are UL i. istwd for recessed appilcaUons such as outdoor cawpys or irHsrior ceilings. Frames available to match painted or stain- lore steel. b ew~mt,,, ~ ~ b. ~ done. , RMF-~-~-A eeeoe~"' 27"x~7-7/8" "'~i/8"x20r RMF-222-A 88QQ8~4 2T' x 17-7/8" 29-I/8" x RMF-342-88-A ~ 36" x 17-7/8" 30-1/8" x 20" RMF.342-A 881XIg14 36" x 17,7/Ir 30-f/8" x RMF-462-88~ 8801039 49" x 11-7/r 51,1/8" x RMF-482~ 8801014 ' 4r x 17-7/8' 51-1/8" x RMF-223-SS 881103g 32'x29-3/8" 34.125'x31.5" RMF-463-SS 8811139 54" x 29-3/8" 58.125' x 31.5" OpUonal Mounting We have engineered a tab on the top of th, heater to suspend it from its mounting bracket/wiring channel while it's being w;red, This means that only One person is needed to install the heater. Wiring channels are full length for con~nU~UI sT'Tel= Sugg~ Mounting Heights 2 or 3 Element MuI,T, Mounts 30°, A30° Indoor ..... ~4' to 30' 60', A60" Indoor ..... 12' to 18' 90° Indoor ......... 30', A30' Outdoor , , ,g' to I O' VMB-41: One inch angle iron bracket used for mounting fixtures at least 36" from a vertical suntare to the center of the heater. Can be used with swivel bracket, Choose stainIra steel O/MB-41SS~ or painted (VM8-413. CHS-3AX: Swivel bracket made from 22 gauge steel, bracket can be tilted up to 30° from horf~rttl. Hardware to bolt to heater provided, Choose steinless steel (CHB-3AX-8I~ or painted (CHB-3AX). Brackets sold ;n pairs. J Mul-T-Mount Reflector Patterns ae" Sp,,,drb r Asme~ · ,'., VMg.4! FO~rOPJA INDUST~ES, INC, Genera! ~Divld0n 1200 N. Matn SL F0stoH~OH44~3Q-OCM (419)436-9201 FAX:(419)435,0942 J P~Y Lx3 '98 e~B:4F~.-~ FOSTORIR INDUSTRIES Shade~....e_re~ ind/~te non-;~ Items end · two week ./ed t/me. Mu!-T-Mount Series Infrared Heaters - Shipped with Ouarlz Lamps I Mr,,dr, I Num~r 'J P~oduct Code 88034f41':.' -:2~/I or3:: '~TH- ~/ 88034142 ""' '.240/1 ~ 3. ': ~-~:~-2~ ~28141 2~/I ~ 3 ~2 -2~ ~ 143 2~1 or 3 ~- 2~ ~8142 2~lt ~ 3 : .;:: ~2',~::' '.~:2~f~7~ 222-~*Tff-~ ~1141 ~1 or 2 2 4 ~1~ 4~/1 ~ 3 ~ ............. ~2-~-~-~ 8~21~ ~-3~~ ~143 4~I or 3 462-~-~V 88~ T ~ 2~-~*~~ ~I ~1 ~ 3 222-~-~2~V 8~25303 2~/1 or 3 222-~-~2~ 8~2 2~/1 or 3 2~t~ 8~83g [ 20~1 ~ 3 2~0-~-2; 860~93 2~1 or 3 222-~2~ 8~ 2~/1 or 3 2~-~-~2~V ~13~ 240/1 or 3 ~2-~-~~ 8~T~2 277/1 ~ 3 ~~2~ ~ 1 ~3 ~ or 1 10,922 :24"xl 5"X7-7/8" 20 !be "/"' 463-60-THSS-,tBOV "~ [ 463-80-THSS-480V 88102391 208/3 or I 88102392 240/3 or ! 88?02393 277/3 or I '~t': :': 'iS f o33e$!:.','." ,'. '.~ 277/3~ ~ :t ~ ~i ~81043~1 208/3 or I 8~104392 240/3 ~r 1 88 ~ .q4393 .... rfl./3 ~r ~.. 88 ~ 05~4 480/3 or I Consult factoff or licenMd electrician for 3-phase wiring of s|| 2-element heaters. 5,000 17,055 33"xl 5"x7-7/5" 25 Ibs 7,300 24,951 46'xl 5"x7-7t8" 32 3,200 10.922 24"xl 5"x7-7/8" 20 Consult factory or !;sensed electrician for 3-phase wlr;ng all 2-element heaters. 5,000 17,065 33"x ! 5 "x7-7/6, 25 7,300 24,951 46'xl 5"x7-7/8" 32 Ibs 4,800 16,382 24"x21 - t/2'x7-~'18 'i0,950" 3~.3f2 46"x~1.1'/2"x7.7/8~ .... ~10'~r~, '